Action not permitted
Modal body text goes here.
CVE-2021-32938
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf | Patch, Third Party Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf | Patch, Third Party Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf | ||
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 | Patch, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-21-980/ | Third Party Advisory, VDB Entry |
▼ | Vendor | Product |
---|---|---|
n/a | Drawings SDK |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:33:55.918Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Drawings SDK", "vendor": "n/a", "versions": [ { "status": "affected", "version": "All versions prior to 2022.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "OUT-OF-BOUNDS READ CWE-125", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-14T00:00:00", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-32938", "datePublished": "2021-06-17T00:00:00", "dateReserved": "2021-05-13T00:00:00", "dateUpdated": "2024-08-03T23:33:55.918Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-32938\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2021-06-17T13:15:07.837\",\"lastModified\":\"2023-02-14T12:15:11.073\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.\"},{\"lang\":\"es\",\"value\":\"Drawings SDK (todas las versiones anteriores a 2022.4) es vulnerable a una lectura fuera de l\u00edmites debido al an\u00e1lisis de archivos DWG resultando en una falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario. Esto puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado y permite a atacantes causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n confidencial de la memoria\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.4\",\"matchCriteriaId\":\"FEFEE0EB-BDA4-4D1A-85B5-0D0A80EE26FA\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.4.1\",\"matchCriteriaId\":\"0F0CFB85-CD4F-424C-8B9F-9289D08FA665\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.1\",\"matchCriteriaId\":\"C811E8B2-CA0C-4A71-A803-A30C4DAF1476\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.1\",\"matchCriteriaId\":\"87BB2370-46C4-4BEC-8189-1F7FE4C1E12D\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-980/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
gsd-2021-32938
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-32938", "description": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "id": "GSD-2021-32938" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-32938" ], "details": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "id": "GSD-2021-32938", "modified": "2023-12-13T01:23:09.088247Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32938", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Drawings SDK", "version": { "version_data": [ { "version_value": "All versions prior to 2022.4" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OUT-OF-BOUNDS READ CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.4.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32938" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-980/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2 } }, "lastModifiedDate": "2023-02-14T12:15Z", "publishedDate": "2021-06-17T13:15Z" } } }
icsa-21-222-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Brian Gorenc" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "Kai Wang" ], "organization": "Codesafe Team of Legendsec at Qi \u0027anxin Group", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Open Design Alliance", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to crash an application or execute arbitrary code.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-365397.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "category": "external", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-365397.txt" } ], "title": "Siemens JT2Go and Teamcenter Visualization products", "tracking": { "current_release_date": "2021-08-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-222-01", "initial_release_date": "2021-08-10T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-222-01 Siemens JT2Go and Teamcenter Visualization products" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.1", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.1", "product": { "name": "Teamcenter Visualization", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32936 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32938 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32940 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32944 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32948 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32950 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-33717", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-33717 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-33717 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-33717.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-33717" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-33717" } ] }
icsa-21-159-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Brian Gorenc" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Siemens ProductCERT", "summary": "assisting coordination with Open Design Alliance" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow code execution in the context of the current process or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-159-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-159-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-159-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-159-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2021-06-08T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-159-02", "initial_release_date": "2021-06-08T00:00:00.000000Z", "revision_history": [ { "date": "2021-06-08T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-159-02 Open Design Alliance Drawings SDK" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 2022.4 (is affected by CVE-2021-32946 and CVE-2021-32952)", "product": { "name": "Drawing SDK: Version 2022.4 is affected by CVE-2021-32946 and CVE-2021-32952", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Drawing SDK" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 2022.4", "product": { "name": "Drawings SDK: All versions prior to 2022.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Drawings SDK" } ], "category": "vendor", "name": "Open Design Alliance" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.CVE-2021-32938 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.CVE-2021-32936 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.CVE-2021-32940 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "An improper check for unusual or exceptional conditions issue exists within the parsing DGN files resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.CVE-2021-32946 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.CVE-2021-32948 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.CVE-2021-32950 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.CVE-2021-32952 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.CVE-2021-32944 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0002" ] } ] } ] }
icsa-23-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Open Design Alliance", "summary": "reporting these vulnerabilities to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "If malicious cyber actor tricks a user into opening a malicious file with the affected applications, it could allow the cyber actor to crash the application, extract data, or arbitrarily execute code.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "if no known exploits exist, the last sentence of the Mitigation section should include the following.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2023-02-20T22:10:45.298464Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-01", "initial_release_date": "2023-02-20T22:10:45.298464Z", "revision_history": [ { "date": "2023-02-20T22:10:45.298464Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003c V222.0MP12", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V223.0Update2", "product": { "name": "Solid Edge SE2023", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2023" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-43391", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43391" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43391" }, { "cve": "CVE-2022-46345", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46345" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46345" }, { "cve": "CVE-2022-46346", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46346" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46346" }, { "cve": "CVE-2022-46347", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46347" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46347" }, { "cve": "CVE-2022-46348", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46348" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46348" }, { "cve": "CVE-2022-46349", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46349" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46349" }, { "cve": "CVE-2023-22295", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22295" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22295" }, { "cve": "CVE-2023-22321", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22321" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22321" }, { "cve": "CVE-2023-22354", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22354" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22354" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22669" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22670" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-22846", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22846" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22846" }, { "cve": "CVE-2023-23579", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-23579" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-23579" }, { "cve": "CVE-2023-24549", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24549" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24549" }, { "cve": "CVE-2023-24550", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24550" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24550" }, { "cve": "CVE-2023-24551", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24551" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24551" }, { "cve": "CVE-2023-24552", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24552" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24552" }, { "cve": "CVE-2023-24553", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24553" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24553" }, { "cve": "CVE-2023-24554", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24554" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24554" }, { "cve": "CVE-2023-24555", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24555" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24555" }, { "cve": "CVE-2023-24556", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24556" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24556" }, { "cve": "CVE-2023-24557", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24557" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24557" }, { "cve": "CVE-2023-24558", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24558" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24558" }, { "cve": "CVE-2023-24559", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24559" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24559" }, { "cve": "CVE-2023-24560", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24560" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24560" }, { "cve": "CVE-2023-24561", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24561" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24561" }, { "cve": "CVE-2023-24562", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24562" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24562" }, { "cve": "CVE-2023-24563", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24563" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24563" }, { "cve": "CVE-2023-24564", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24564" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24564" }, { "cve": "CVE-2023-24565", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24565" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24565" }, { "cve": "CVE-2023-24566", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24566" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24566" }, { "cve": "CVE-2023-24581", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24581" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24581" }, { "cve": "CVE-2023-25140", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-25140" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-25140" } ] }
icsa-22-069-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may result in leaked information or remote code execution in the context of the current process.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-155599.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-069-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-069-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2022-03-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-069-06", "initial_release_date": "2022-03-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-069-06 Siemens COMOS" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V10.4.1", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-25173", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25173 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25173" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25173" }, { "cve": "CVE-2021-25174", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12026)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25174 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25174" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25174" }, { "cve": "CVE-2021-25175", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type conversion vulnerability while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25175 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25175" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25175" }, { "cve": "CVE-2021-25176", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a NULL pointer dereference vulnerability while parsing DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11913, ZDI-CAN-11989)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25176 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25176 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25176" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25176" }, { "cve": "CVE-2021-25177", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type confusion issue while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11927)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25177 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25177 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25177" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25177" }, { "cve": "CVE-2021-25178", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a stack-based buffer overflow vulnerability while parsing specially crafted DXF or DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25178 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25178 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25178" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25178" }, { "cve": "CVE-2021-31784", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.6 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-11915)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-31784 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-31784 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-31784" }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32936 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32938 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13412)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32940 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a use-after-free vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-13468, ZDI-CAN-13413)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32944 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to improper check for unusual or exceptional conditions while parsing specially crafted DGN files. This could allow an attacker to cause a denial-of-service condition or execute code in the context of the current process. (ZDI-CAN-13411, ZDI-CAN-13409)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32946 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32946 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32946" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32948 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DXF files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13415)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32950 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DGN files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13417)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32952 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32952 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32952" } ] }
ghsa-339v-pgj2-77h7
Vulnerability from github
Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.
{ "affected": [], "aliases": [ "CVE-2021-32938" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-06-17T13:15:00Z", "severity": "HIGH" }, "details": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "id": "GHSA-339v-pgj2-77h7", "modified": "2022-05-24T19:05:36Z", "published": "2022-05-24T19:05:36Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-32938" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-980" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "type": "CVSS_V3" } ] }
var-202106-1189
Vulnerability from variot
Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory. Open Design Alliance Provided by Drawings SDK is a drafting software development kit. This product contains multiple vulnerabilities listed below. * Out-of-bounds read (CWE-125) - CVE-2021-32938 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32936 It was * Out-of-bounds read (CWE-125) - CVE-2021-32940 It was * DGN Improper checking of files for abnormal or exceptional conditions (CWE-754) - CVE-2021-32946 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32948 It was * Out-of-bounds read (CWE-125) - CVE-2021-32950 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32952 It was * Use of freed memory (use-after-free) (CWE-416) - CVE-2021-32944The expected impact depends on each vulnerability, but it may be affected as follows. It was * crafted by the attacker DWG Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32938 It was * crafted by the attacker DXF Denial of service by opening files via recovery (DoS) state is triggered or code is executed - CVE-2021-32936 It was * crafted by the attacker DWG Denial of service by opening files via recovery (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32940 It was * crafted by the attacker DGN Denial of service by reading the file (DoS) state is triggered or code is executed - CVE-2021-32946 , CVE-2021-32952 It was * crafted by the attacker DWG Denial of service by opening the file (DoS) state is triggered or code is executed - CVE-2021-32948 It was * crafted by the attacker DXF Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32950 It was * Crafted by an attacker by an attacker DGN Denial of service by opening the file (DoS) A condition is triggered or arbitrary code is executed - CVE-2021-32944. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DWG files. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages. A buffer error vulnerability exists in the Drawings SDK that arises from a boundary condition. Affected products and versions are as follows: Drawings SDK: Before 2022.4
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202106-1189", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "drawing sdk", "scope": null, "trust": 1.4, "vendor": "open design alliance oda", "version": null }, { "model": "drawings sdk", "scope": "lt", "trust": 1.0, "vendor": "opendesign", "version": "2022.4" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0.1" }, { "model": "comos", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "10.4.1" }, { "model": "jt2go", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0.1" }, { "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": "2022.4 all previous s - cve-2021-32938 , cve-2021-32936 , cve-2021-32940 , cve-2021-32948 , cve-2021-32950 , cve-2021-32944" }, { "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": "2022.5 all previous s - cve-2021-32946 , cve-2021-32952" }, { "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": null }, { "model": "jt2go", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null }, { "model": "solid edge viewer", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.4.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-32938" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mat Powell of Trend Micro Zero Day Initiative", "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ], "trust": 2.0 }, "cve": "CVE-2021-32938", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 4.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-392924", "impactScore": 4.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-32938", "impactScore": 4.9, "integrityImpact": "NONE", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 1.8, "id": "CVE-2021-32938", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.4, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-32938", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.4, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA", "availabilityImpact": "Low", "baseScore": 4.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-001881", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" } ], "severity": [ { "author": "ZDI", "id": "CVE-2021-32938", "trust": 1.4, "value": "LOW" }, { "author": "ZDI", "id": "CVE-2021-32938", "trust": 1.4, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-32938", "trust": 1.0, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2021-001881", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202106-686", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-392924", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-32938", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "VULHUB", "id": "VHN-392924" }, { "db": "VULMON", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory. Open Design Alliance Provided by Drawings SDK is a drafting software development kit. This product contains multiple vulnerabilities listed below. * Out-of-bounds read (CWE-125) - CVE-2021-32938 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32936 It was * Out-of-bounds read (CWE-125) - CVE-2021-32940 It was * DGN Improper checking of files for abnormal or exceptional conditions (CWE-754) - CVE-2021-32946 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32948 It was * Out-of-bounds read (CWE-125) - CVE-2021-32950 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32952 It was * Use of freed memory (use-after-free) (CWE-416) - CVE-2021-32944The expected impact depends on each vulnerability, but it may be affected as follows. It was * crafted by the attacker DWG Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32938 It was * crafted by the attacker DXF Denial of service by opening files via recovery (DoS) state is triggered or code is executed - CVE-2021-32936 It was * crafted by the attacker DWG Denial of service by opening files via recovery (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32940 It was * crafted by the attacker DGN Denial of service by reading the file (DoS) state is triggered or code is executed - CVE-2021-32946 , CVE-2021-32952 It was * crafted by the attacker DWG Denial of service by opening the file (DoS) state is triggered or code is executed - CVE-2021-32948 It was * crafted by the attacker DXF Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32950 It was * Crafted by an attacker by an attacker DGN Denial of service by opening the file (DoS) A condition is triggered or arbitrary code is executed - CVE-2021-32944. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DWG files. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages. A buffer error vulnerability exists in the Drawings SDK that arises from a boundary condition. Affected products and versions are as follows: Drawings SDK: Before 2022.4", "sources": [ { "db": "NVD", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULHUB", "id": "VHN-392924" }, { "db": "VULMON", "id": "CVE-2021-32938" } ], "trust": 4.86 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-32938", "trust": 6.2 }, { "db": "ICS CERT", "id": "ICSA-21-159-02", "trust": 2.6 }, { "db": "ZDI", "id": "ZDI-21-980", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-155599", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-491245", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-365397", "trust": 1.8 }, { "db": "JVN", "id": "JVNVU97514209", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU95145431", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-047-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-001881", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-13378", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19161", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-135", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19146", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-129", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19073", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-207", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-22-069-06", "trust": 0.7 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2023.0960", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2700", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.1047", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2046", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022031102", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021081108", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021060909", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-222-01", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202106-686", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-392924", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2021-32938", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "VULHUB", "id": "VHN-392924" }, { "db": "VULMON", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "id": "VAR-202106-1189", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-392924" } ], "trust": 0.25799868000000004 }, "last_update_date": "2023-12-18T11:10:31.632000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "", "trust": 1.4, "url": "https://www.opendesign.com/security-advisories" }, { "title": "Open\u00a0Design\u00a0Alliance\u00a0( Login required ) Open\u00a0Design\u00a0Alliance", "trust": 0.8, "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=movingtonewversion.html" }, { "title": "", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "title": "Open Design Alliance Drawings SDK Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=154863" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=dce38d2a1ec28e091a143e851596b2e8" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=b2237aa5ac819041f827cc4fd4128631" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "VULMON", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.1 }, { "problemtype": "Out-of-bounds read (CWE-125) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Use of freed memory (CWE-416) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Improper checking in exceptional conditions (CWE-754) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Out-of-bounds writing (CWE-787) [IPA evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-392924" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "trust": 2.5, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-980/" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "trust": 1.4, "url": "https://www.opendesign.com/security-advisories" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32938" }, { "trust": 0.8, "url": "http://jvn.jp/cert/jvnvu95145431" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu97514209/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32936" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32940" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32944" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32946" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32948" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32950" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32952" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-047-01" }, { "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.1047" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2046" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021081108" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2023.0960" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2700" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021060909" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/125.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-069-06" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "VULHUB", "id": "VHN-392924" }, { "db": "VULMON", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-980" }, { "db": "ZDI", "id": "ZDI-23-135" }, { "db": "ZDI", "id": "ZDI-23-129" }, { "db": "ZDI", "id": "ZDI-23-207" }, { "db": "VULHUB", "id": "VHN-392924" }, { "db": "VULMON", "id": "CVE-2021-32938" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32938" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-18T00:00:00", "db": "ZDI", "id": "ZDI-21-980" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-135" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-129" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-207" }, { "date": "2021-06-17T00:00:00", "db": "VULHUB", "id": "VHN-392924" }, { "date": "2021-06-17T00:00:00", "db": "VULMON", "id": "CVE-2021-32938" }, { "date": "2021-06-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "date": "2021-06-17T13:15:07.837000", "db": "NVD", "id": "CVE-2021-32938" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-06-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-18T00:00:00", "db": "ZDI", "id": "ZDI-21-980" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-135" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-129" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-207" }, { "date": "2023-02-14T00:00:00", "db": "VULHUB", "id": "VHN-392924" }, { "date": "2023-02-14T00:00:00", "db": "VULMON", "id": "CVE-2021-32938" }, { "date": "2023-02-17T05:48:00", "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "date": "2023-02-14T12:15:11.073000", "db": "NVD", "id": "CVE-2021-32938" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2023-02-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-686" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-686" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Open\u00a0Design\u00a0Alliance\u00a0 Made \u00a0Drawings\u00a0SDK\u00a0 Multiple vulnerabilities in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001881" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.