CVE-2022-2137
Vulnerability from cvelistv5
Published
2022-07-22 14:57
Modified
2024-09-17 00:30
Summary
Advantech iView
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03Third Party Advisory, US Government Resource
Impacted products
Advantech iViewiView
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:44.261Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iView",
          "vendor": "Advantech iView",
          "versions": [
            {
              "lessThan": "5_7_04_6469",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "rgod, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
        }
      ],
      "datePublic": "2022-06-28T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected product is vulnerable to two SQL injections that require high privileges for exploitation and may allow an unauthorized attacker to disclose information"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-22T14:57:57",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities."
        }
      ],
      "source": {
        "advisory": "ICSA-22-179-03",
        "discovery": "EXTERNAL"
      },
      "title": "Advantech iView",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-28T17:00:00.000Z",
          "ID": "CVE-2022-2137",
          "STATE": "PUBLIC",
          "TITLE": "Advantech iView"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iView",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "5_7_04_6469"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Advantech iView"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "rgod, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected product is vulnerable to two SQL injections that require high privileges for exploitation and may allow an unauthorized attacker to disclose information"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities."
          }
        ],
        "source": {
          "advisory": "ICSA-22-179-03",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2137",
    "datePublished": "2022-07-22T14:57:57.232721Z",
    "dateReserved": "2022-06-20T00:00:00",
    "dateUpdated": "2024-09-17T00:30:56.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-2137\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-07-22T15:15:08.237\",\"lastModified\":\"2022-07-28T20:10:50.920\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The affected product is vulnerable to two SQL injections that require high privileges for exploitation and may allow an unauthorized attacker to disclose information\"},{\"lang\":\"es\",\"value\":\"El producto afectado es vulnerable a dos inyecciones SQL que requieren altos privilegios para su explotaci\u00f3n y pueden permitir a un atacante no autorizado divulgar informaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:iview:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.7.04.6469\",\"matchCriteriaId\":\"EC3EA62D-5DEE-46D5-BA3D-BD9F745F1191\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.