CVE-2022-22151 (GCVE-0-2022-22151)

Vulnerability from cvelistv5 – Published: 2022-03-11 09:10 – Updated: 2024-08-03 03:07
VLAI?
Summary
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
Severity ?
No CVSS data available.
CWE
  • CWE-117 - Improper Output Neutralization for Logs
Assigner
References
Impacted products
Vendor Product Version
Yokogawa Electric Corporation CENTUM CS 3000 Affected: versions from R3.08.10 to R3.09.00
Create a notification for this product.
    Yokogawa Electric Corporation CENTUM VP Affected: versions from R4.01.00 to R4.03.00
Affected: versions from R5.01.00 to R5.04.20
Affected: versions from R6.01.00 to R6.08.00
Create a notification for this product.
    Yokogawa Electric Corporation Exaopc Affected: versions from R3.72.00 to R3.79.00
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:07:48.306Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CENTUM CS 3000",
          "vendor": "Yokogawa Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions from R3.08.10 to R3.09.00"
            }
          ]
        },
        {
          "product": "CENTUM VP",
          "vendor": "Yokogawa Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions from R4.01.00 to R4.03.00"
            },
            {
              "status": "affected",
              "version": "versions from R5.01.00 to R5.04.20"
            },
            {
              "status": "affected",
              "version": "versions from R6.01.00 to R6.08.00"
            }
          ]
        },
        {
          "product": "Exaopc",
          "vendor": "Yokogawa Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions from R3.72.00 to R3.79.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-117",
              "description": "CWE-117: Improper Output Neutralization for Logs",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-11T09:10:48",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-22151",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CENTUM CS 3000",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions from R3.08.10 to R3.09.00"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CENTUM VP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions from R4.01.00 to R4.03.00"
                          },
                          {
                            "version_value": "versions from R5.01.00 to R5.04.20"
                          },
                          {
                            "version_value": "versions from R6.01.00 to R6.08.00"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Exaopc",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions from R3.72.00 to R3.79.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Yokogawa Electric Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-117: Improper Output Neutralization for Logs"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf",
              "refsource": "CONFIRM",
              "url": "https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-22151",
    "datePublished": "2022-03-11T09:10:48",
    "dateReserved": "2022-02-03T00:00:00",
    "dateUpdated": "2024-08-03T03:07:48.306Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_cs_3000_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r3.08.10\", \"versionEndIncluding\": \"r3.09.00\", \"matchCriteriaId\": \"9D7B6EFE-A886-4409-BE19-E67C0057265B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:yokogawa:centum_cs_3000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BAF123F6-D4A3-49B3-B8BC-14AA63E3A46A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_cs_3000_entry_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r3.08.10\", \"versionEndIncluding\": \"r3.09.00\", \"matchCriteriaId\": \"CBD66947-E8ED-45FC-8A71-14D4CB8D7368\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:yokogawa:centum_cs_3000_entry:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"67BFCAD6-7540-4279-92C5-9ADAB35CD4A7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r4.01.00\", \"versionEndIncluding\": \"r4.03.00\", \"matchCriteriaId\": \"D0D63842-D6A8-4FA1-B09C-71E9113FF95A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r5.01.00\", \"versionEndIncluding\": \"r5.04.20\", \"matchCriteriaId\": \"D647BA49-5A43-437B-8C58-0294A452AF8D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r6.01.00\", \"versionEndExcluding\": \"r6.09.00\", \"matchCriteriaId\": \"01914A03-6248-4183-94FE-64902B0D1DDF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:yokogawa:centum_vp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"161A4767-228C-4681-9D20-81D9380CE48A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r4.01.00\", \"versionEndIncluding\": \"r4.03.00\", \"matchCriteriaId\": \"1CDBFA61-421D-484C-B33E-938CD58BDCEE\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r5.01.00\", \"versionEndIncluding\": \"r5.04.20\", \"matchCriteriaId\": \"B25462B1-4031-4FAB-8C67-CF060BE472B3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r6.01.00\", \"versionEndExcluding\": \"r6.09.00\", \"matchCriteriaId\": \"27CBFAD9-1DD0-4B18-B8F6-6EB8F6396556\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:yokogawa:centum_vp_entry:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6E37ECBA-48F6-456A-AE49-83347A91208B\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:yokogawa:exaopc:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"r3.72.00\", \"versionEndExcluding\": \"r3.80.00\", \"matchCriteriaId\": \"4D5233E5-DABF-4CCE-A92F-F437DECFBCB9\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.\"}, {\"lang\": \"es\", \"value\": \"CAMS for HIS Log Server contenido en los siguientes productos de Yokogawa Electric no neutraliza apropiadamente las salidas de registro: CENTUM CS 3000 versiones desde R3.08.10 a R3.09.00, CENTUM VP versiones desde R4.01.00 a R4.03.00, de R5.01.00 a R5.04.20, y desde R6.01.00 a R6.08.00, y Exaopc versiones desde R3.72.00 a R3.79.00\"}]",
      "id": "CVE-2022-22151",
      "lastModified": "2024-11-21T06:46:15.690",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:P\", \"baseScore\": 4.9, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 6.8, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-03-11T09:15:11.627",
      "references": "[{\"url\": \"https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"vultures@jpcert.or.jp\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-117\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-116\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-22151\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2022-03-11T09:15:11.627\",\"lastModified\":\"2024-11-21T06:46:15.690\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.\"},{\"lang\":\"es\",\"value\":\"CAMS for HIS Log Server contenido en los siguientes productos de Yokogawa Electric no neutraliza apropiadamente las salidas de registro: CENTUM CS 3000 versiones desde R3.08.10 a R3.09.00, CENTUM VP versiones desde R4.01.00 a R4.03.00, de R5.01.00 a R5.04.20, y desde R6.01.00 a R6.08.00, y Exaopc versiones desde R3.72.00 a R3.79.00\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:P\",\"baseScore\":4.9,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-117\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-116\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_cs_3000_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r3.08.10\",\"versionEndIncluding\":\"r3.09.00\",\"matchCriteriaId\":\"9D7B6EFE-A886-4409-BE19-E67C0057265B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:yokogawa:centum_cs_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BAF123F6-D4A3-49B3-B8BC-14AA63E3A46A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_cs_3000_entry_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r3.08.10\",\"versionEndIncluding\":\"r3.09.00\",\"matchCriteriaId\":\"CBD66947-E8ED-45FC-8A71-14D4CB8D7368\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:yokogawa:centum_cs_3000_entry:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67BFCAD6-7540-4279-92C5-9ADAB35CD4A7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r4.01.00\",\"versionEndIncluding\":\"r4.03.00\",\"matchCriteriaId\":\"D0D63842-D6A8-4FA1-B09C-71E9113FF95A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r5.01.00\",\"versionEndIncluding\":\"r5.04.20\",\"matchCriteriaId\":\"D647BA49-5A43-437B-8C58-0294A452AF8D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r6.01.00\",\"versionEndExcluding\":\"r6.09.00\",\"matchCriteriaId\":\"01914A03-6248-4183-94FE-64902B0D1DDF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:yokogawa:centum_vp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"161A4767-228C-4681-9D20-81D9380CE48A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r4.01.00\",\"versionEndIncluding\":\"r4.03.00\",\"matchCriteriaId\":\"1CDBFA61-421D-484C-B33E-938CD58BDCEE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r5.01.00\",\"versionEndIncluding\":\"r5.04.20\",\"matchCriteriaId\":\"B25462B1-4031-4FAB-8C67-CF060BE472B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:yokogawa:centum_vp_entry_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r6.01.00\",\"versionEndExcluding\":\"r6.09.00\",\"matchCriteriaId\":\"27CBFAD9-1DD0-4B18-B8F6-6EB8F6396556\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:yokogawa:centum_vp_entry:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E37ECBA-48F6-456A-AE49-83347A91208B\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:yokogawa:exaopc:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r3.72.00\",\"versionEndExcluding\":\"r3.80.00\",\"matchCriteriaId\":\"4D5233E5-DABF-4CCE-A92F-F437DECFBCB9\"}]}]}],\"references\":[{\"url\":\"https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://web-material3.yokogawa.com/1/32094/files/YSAR-22-0001-E.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…