CVE-2022-22560 (GCVE-0-2022-22560)

Vulnerability from cvelistv5 – Published: 2022-04-12 17:50 – Updated: 2024-09-16 21:04
VLAI?
Summary
Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Dell PowerScale OneFS Affected: 8.1.x-9.2.1.x
Create a notification for this product.
Date Public ?
2022-01-31 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.654Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000195815"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerScale OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "8.1.x-9.2.1.x"
            }
          ]
        }
      ],
      "datePublic": "2022-01-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T17:50:44.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000195815"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-01-31",
          "ID": "CVE-2022-22560",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerScale OneFS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.1.x-9.2.1.x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.1,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000195815",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000195815"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-22560",
    "datePublished": "2022-04-12T17:50:44.227Z",
    "dateReserved": "2022-01-04T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:04:34.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-22560",
      "date": "2026-05-02",
      "epss": "0.00034",
      "percentile": "0.09829"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.1.0\", \"versionEndIncluding\": \"9.2.1.0\", \"matchCriteriaId\": \"57D52E13-699B-4AA8-846A-7E4764DA5C79\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline.\"}, {\"lang\": \"es\", \"value\": \"Dell EMC PowerScale OneFS 8.1.x - 9.1.x contienen credenciales embebidas. Esto permite a un usuario local con conocimiento de las credenciales iniciar sesi\\u00f3n como usuario administrador en el conmutador ethernet backend de un cl\\u00faster PowerScale. El atacante puede aprovechar esta vulnerabilidad para desconectar el conmutador\"}]",
      "id": "CVE-2022-22560",
      "lastModified": "2024-11-21T06:47:01.677",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:N/I:N/A:C\", \"baseScore\": 4.9, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-04-12T18:15:08.620",
      "references": "[{\"url\": \"https://www.dell.com/support/kbdoc/000195815\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/000195815\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "security_alert@emc.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-22560\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-04-12T18:15:08.620\",\"lastModified\":\"2024-11-21T06:47:01.677\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline.\"},{\"lang\":\"es\",\"value\":\"Dell EMC PowerScale OneFS 8.1.x - 9.1.x contienen credenciales embebidas. Esto permite a un usuario local con conocimiento de las credenciales iniciar sesi\u00f3n como usuario administrador en el conmutador ethernet backend de un cl\u00faster PowerScale. El atacante puede aprovechar esta vulnerabilidad para desconectar el conmutador\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":4.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.1.0\",\"versionEndIncluding\":\"9.2.1.0\",\"matchCriteriaId\":\"57D52E13-699B-4AA8-846A-7E4764DA5C79\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000195815\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000195815\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…