CVE-2022-46350
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:31
Severity ?
Summary
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:31:45.890Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363821.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X204RNA (HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA (PRP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (PRP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (PRP/HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions \u003c V3.2.7), SCALANCE X204RNA (PRP) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions \u003c V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363821.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46350",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-30T00:00:00",
    "dateUpdated": "2024-08-03T14:31:45.890Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-46350\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-12-13T16:15:25.667\",\"lastModified\":\"2022-12-15T20:58:58.180\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions \u003c V3.2.7), SCALANCE X204RNA (PRP) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions \u003c V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions \u003c V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en:\\nSCALANCE X204RNA (HSR) (Todas las versiones \u0026lt; V3.2.7), \\nSCALANCE X204RNA (PRP) (Todas las versiones \u0026lt; V3.2.7), \\nSCALANCE X204RNA EEC (HSR) (Todas las versiones \u0026lt; V3.2.7 ), \\nSCALANCE X204RNA EEC (PRP) (todas las versiones \u0026lt; V3.2.7), \\nSCALANCE X204RNA EEC (PRP/HSR) (todas las versiones \u0026lt; V3.2.7). \\nEl servidor web integrado podr\u00eda permitir ataques de Cross-Site Scripting (XSS) si se enga\u00f1a a usuarios desprevenidos para que accedan a un enlace malicioso. Un atacante puede utilizar esto para desencadenar una solicitud maliciosa en el dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5204-0ba00-2mb2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AF6E5E68-552D-40C1-A4AB-605D0F21688F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5204-0ba00-2mb2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.7\",\"matchCriteriaId\":\"77A54E43-E9A5-49CF-BA3C-E6878C2C713F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5204-0ba00-2kb2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B61CA05-D98E-4BD6-BE78-58574B2DE5CA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5204-0ba00-2kb2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.7\",\"matchCriteriaId\":\"CE326B9F-A613-46B5-A20D-BE9D41A80857\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5204-0bs00-2na3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"28B98E8F-0E32-4BA4-8237-055BDB25C1B3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5204-0bs00-2na3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.7\",\"matchCriteriaId\":\"F6FCF31E-22CA-4038-AC27-BAEA752A718D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5204-0bs00-3la3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D92CFF31-E138-49D0-A9FF-A91E7342AEFC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5204-0bs00-3la3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.7\",\"matchCriteriaId\":\"A7EA94F5-1AB0-4BE2-810A-46B840070856\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5204-0bs00-3pa3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1572F77B-98B7-44D9-9DF9-9EC56CD6E571\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5204-0bs00-3pa3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.7\",\"matchCriteriaId\":\"06CBD11B-3671-425B-89EB-4B9677B3316B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-363821.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.