Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-22809 (GCVE-0-2023-22809)
Vulnerability from cvelistv5 – Published: 2023-01-18 00:00 – Updated: 2025-04-04 15:45- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:20:30.856Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.sudo.ws/security/advisories/sudoedit_any/"
},
{
"name": "[debian-lts-announce] 20230118 [SECURITY] [DLA 3272-1] sudo security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html"
},
{
"name": "DSA-5321",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2023/dsa-5321"
},
{
"name": "[oss-security] 20230119 CVE-2023-22809: Sudoedit can edit arbitrary files",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2023/01/19/1"
},
{
"name": "FEDORA-2023-9078f609e6",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20230127-0015/"
},
{
"name": "FEDORA-2023-298c136eee",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html"
},
{
"name": "GLSA-202305-12",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202305-12"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.apple.com/kb/HT213758"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html"
},
{
"name": "20230817 KL-001-2023-003: Cisco ThousandEyes Enterprise Agent Virtual Appliance Arbitrary File Modification via sudoedit",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2023/Aug/21"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-22809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T15:43:57.601703Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T15:45:24.835Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Sudo before 1.9.12p2, the sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This can lead to privilege escalation. Affected versions are 1.8.0 through 1.9.12.p1. The problem exists because a user-specified editor may contain a \"--\" argument that defeats a protection mechanism, e.g., an EDITOR=\u0027vim -- /path/to/extra/file\u0027 value."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-06T07:06:47.365Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf"
},
{
"url": "https://www.sudo.ws/security/advisories/sudoedit_any/"
},
{
"name": "[debian-lts-announce] 20230118 [SECURITY] [DLA 3272-1] sudo security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html"
},
{
"name": "DSA-5321",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2023/dsa-5321"
},
{
"name": "[oss-security] 20230119 CVE-2023-22809: Sudoedit can edit arbitrary files",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2023/01/19/1"
},
{
"name": "FEDORA-2023-9078f609e6",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20230127-0015/"
},
{
"name": "FEDORA-2023-298c136eee",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/"
},
{
"url": "http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html"
},
{
"name": "GLSA-202305-12",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202305-12"
},
{
"url": "https://support.apple.com/kb/HT213758"
},
{
"url": "http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html"
},
{
"name": "20230817 KL-001-2023-003: Cisco ThousandEyes Enterprise Agent Virtual Appliance Arbitrary File Modification via sudoedit",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2023/Aug/21"
},
{
"url": "http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-22809",
"datePublished": "2023-01-18T00:00:00.000Z",
"dateReserved": "2023-01-06T00:00:00.000Z",
"dateUpdated": "2025-04-04T15:45:24.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-22809",
"date": "2026-05-21",
"epss": "0.48016",
"percentile": "0.97762"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:sudo_project:sudo:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.8.0\", \"versionEndExcluding\": \"1.9.12\", \"matchCriteriaId\": \"E76D2160-BE9D-4C9E-B2AB-B52B3C84DAD7\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:sudo_project:sudo:1.9.12:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"30B5DA3F-091D-4627-A5C0-2D1487A378B0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:sudo_project:sudo:1.9.12:p1:*:*:*:*:*:*\", \"matchCriteriaId\": \"F30DC131-EACB-47C6-B6B7-FCB78DDBD059\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FA6FEEC2-9F11-4643-8827-749718254FED\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fedoraproject:fedora:36:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5C675112-476C-4D7C-BCB9-A2FB2D0BC9FD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fedoraproject:fedora:37:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E30D0E6F-4AE8-4284-8716-991DFA48CC5D\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:apple:macos:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"13.4\", \"matchCriteriaId\": \"ADD1755A-5CD2-4EED-8C6C-4729FADFA3F5\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"In Sudo before 1.9.12p2, the sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This can lead to privilege escalation. Affected versions are 1.8.0 through 1.9.12.p1. The problem exists because a user-specified editor may contain a \\\"--\\\" argument that defeats a protection mechanism, e.g., an EDITOR=\u0027vim -- /path/to/extra/file\u0027 value.\"}, {\"lang\": \"es\", \"value\": \"En Sudo anterior a 1.9.12p2, la funci\\u00f3n sudoedit (tambi\\u00e9n conocida como -e) maneja mal argumentos adicionales pasados en las variables de entorno proporcionadas por el usuario (SUDO_EDITOR, VISUAL y EDITOR), permitiendo a un atacante local agregar entradas arbitrarias a la lista de archivos para procesar. . Esto puede conducir a una escalada de privilegios. Las versiones afectadas son 1.8.0 a 1.9.12.p1. El problema existe porque un editor especificado por el usuario puede contener un argumento \\\"--\\\" que anula un mecanismo de protecci\\u00f3n, por ejemplo, un valor EDITOR=\u0027vim -- /path/to/extra/file\u0027.\"}]",
"id": "CVE-2023-22809",
"lastModified": "2024-11-21T07:45:27.753",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
"published": "2023-01-18T17:15:10.353",
"references": "[{\"url\": \"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://seclists.org/fulldisclosure/2023/Aug/21\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"http://www.openwall.com/lists/oss-security/2023/01/19/1\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mailing List\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mailing List\"]}, {\"url\": \"https://security.gentoo.org/glsa/202305-12\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0015/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.apple.com/kb/HT213758\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5321\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.sudo.ws/security/advisories/sudoedit_any/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Mitigation\", \"Technical Description\", \"Third Party Advisory\"]}, {\"url\": \"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://seclists.org/fulldisclosure/2023/Aug/21\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"http://www.openwall.com/lists/oss-security/2023/01/19/1\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mailing List\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mailing List\"]}, {\"url\": \"https://security.gentoo.org/glsa/202305-12\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0015/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.apple.com/kb/HT213758\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5321\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.sudo.ws/security/advisories/sudoedit_any/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Mitigation\", \"Technical Description\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-22809\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-01-18T17:15:10.353\",\"lastModified\":\"2025-04-04T16:15:16.850\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Sudo before 1.9.12p2, the sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This can lead to privilege escalation. Affected versions are 1.8.0 through 1.9.12.p1. The problem exists because a user-specified editor may contain a \\\"--\\\" argument that defeats a protection mechanism, e.g., an EDITOR=\u0027vim -- /path/to/extra/file\u0027 value.\"},{\"lang\":\"es\",\"value\":\"En Sudo anterior a 1.9.12p2, la funci\u00f3n sudoedit (tambi\u00e9n conocida como -e) maneja mal argumentos adicionales pasados en las variables de entorno proporcionadas por el usuario (SUDO_EDITOR, VISUAL y EDITOR), permitiendo a un atacante local agregar entradas arbitrarias a la lista de archivos para procesar. . Esto puede conducir a una escalada de privilegios. Las versiones afectadas son 1.8.0 a 1.9.12.p1. El problema existe porque un editor especificado por el usuario puede contener un argumento \\\"--\\\" que anula un mecanismo de protecci\u00f3n, por ejemplo, un valor EDITOR=\u0027vim -- /path/to/extra/file\u0027.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:sudo_project:sudo:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.8.0\",\"versionEndExcluding\":\"1.9.12\",\"matchCriteriaId\":\"E76D2160-BE9D-4C9E-B2AB-B52B3C84DAD7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:sudo_project:sudo:1.9.12:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"30B5DA3F-091D-4627-A5C0-2D1487A378B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:sudo_project:sudo:1.9.12:p1:*:*:*:*:*:*\",\"matchCriteriaId\":\"F30DC131-EACB-47C6-B6B7-FCB78DDBD059\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA6FEEC2-9F11-4643-8827-749718254FED\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fedoraproject:fedora:36:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C675112-476C-4D7C-BCB9-A2FB2D0BC9FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fedoraproject:fedora:37:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E30D0E6F-4AE8-4284-8716-991DFA48CC5D\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:apple:macos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.4\",\"matchCriteriaId\":\"ADD1755A-5CD2-4EED-8C6C-4729FADFA3F5\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://seclists.org/fulldisclosure/2023/Aug/21\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://www.openwall.com/lists/oss-security/2023/01/19/1\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://security.gentoo.org/glsa/202305-12\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20230127-0015/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.apple.com/kb/HT213758\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5321\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.sudo.ws/security/advisories/sudoedit_any/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Mitigation\",\"Technical Description\",\"Third Party Advisory\"]},{\"url\":\"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://seclists.org/fulldisclosure/2023/Aug/21\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://www.openwall.com/lists/oss-security/2023/01/19/1\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\"]},{\"url\":\"https://security.gentoo.org/glsa/202305-12\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20230127-0015/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.apple.com/kb/HT213758\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.debian.org/security/2023/dsa-5321\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.sudo.ws/security/advisories/sudoedit_any/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Mitigation\",\"Technical Description\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.sudo.ws/security/advisories/sudoedit_any/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\", \"name\": \"[debian-lts-announce] 20230118 [SECURITY] [DLA 3272-1] sudo security update\", \"tags\": [\"mailing-list\", \"x_transferred\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5321\", \"name\": \"DSA-5321\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"http://www.openwall.com/lists/oss-security/2023/01/19/1\", \"name\": \"[oss-security] 20230119 CVE-2023-22809: Sudoedit can edit arbitrary files\", \"tags\": [\"mailing-list\", \"x_transferred\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\", \"name\": \"FEDORA-2023-9078f609e6\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0015/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\", \"name\": \"FEDORA-2023-298c136eee\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://security.gentoo.org/glsa/202305-12\", \"name\": \"GLSA-202305-12\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://support.apple.com/kb/HT213758\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://seclists.org/fulldisclosure/2023/Aug/21\", \"name\": \"20230817 KL-001-2023-003: Cisco ThousandEyes Enterprise Agent Virtual Appliance Arbitrary File Modification via sudoedit\", \"tags\": [\"mailing-list\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T10:20:30.856Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-22809\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-04T15:43:57.601703Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-269\", \"description\": \"CWE-269 Improper Privilege Management\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-04T15:45:18.109Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.synacktiv.com/sites/default/files/2023-01/sudo-CVE-2023-22809.pdf\"}, {\"url\": \"https://www.sudo.ws/security/advisories/sudoedit_any/\"}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00012.html\", \"name\": \"[debian-lts-announce] 20230118 [SECURITY] [DLA 3272-1] sudo security update\", \"tags\": [\"mailing-list\"]}, {\"url\": \"https://www.debian.org/security/2023/dsa-5321\", \"name\": \"DSA-5321\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"http://www.openwall.com/lists/oss-security/2023/01/19/1\", \"name\": \"[oss-security] 20230119 CVE-2023-22809: Sudoedit can edit arbitrary files\", \"tags\": [\"mailing-list\"]}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2QDGFCGAV5QRJCE6IXRXIS4XJHS57DDH/\", \"name\": \"FEDORA-2023-9078f609e6\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0015/\"}, {\"url\": \"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/G4YNBTTKTRT2ME3NTSXAPTOKYUE47XHZ/\", \"name\": \"FEDORA-2023-298c136eee\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"http://packetstormsecurity.com/files/171644/sudo-1.9.12p1-Privilege-Escalation.html\"}, {\"url\": \"https://security.gentoo.org/glsa/202305-12\", \"name\": \"GLSA-202305-12\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://support.apple.com/kb/HT213758\"}, {\"url\": \"http://packetstormsecurity.com/files/172509/Sudoedit-Extra-Arguments-Privilege-Escalation.html\"}, {\"url\": \"http://seclists.org/fulldisclosure/2023/Aug/21\", \"name\": \"20230817 KL-001-2023-003: Cisco ThousandEyes Enterprise Agent Virtual Appliance Arbitrary File Modification via sudoedit\", \"tags\": [\"mailing-list\"]}, {\"url\": \"http://packetstormsecurity.com/files/174234/Cisco-ThousandEyes-Enterprise-Agent-Virtual-Appliance-Arbitrary-File-Modification.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"In Sudo before 1.9.12p2, the sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This can lead to privilege escalation. Affected versions are 1.8.0 through 1.9.12.p1. The problem exists because a user-specified editor may contain a \\\"--\\\" argument that defeats a protection mechanism, e.g., an EDITOR=\u0027vim -- /path/to/extra/file\u0027 value.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-09-06T07:06:47.365Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-22809\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-04T15:45:24.835Z\", \"dateReserved\": \"2023-01-06T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2023-01-18T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
2NGA002579
Vulnerability from csaf_abb - Published: 2025-04-07 10:30 - Updated: 2025-04-07 10:30Vulnerability in Git that arises from an issue with git attributes parsing. This flaw can lead to an integer overflow, which might be exploited by authenticated attackers to execute arbitrary code or cause a denial of service.
CWE-190 - Integer Overflow or Wraparound| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Vulnerability in Git that involves a heap overflow in the git archive and git log --format commands. This flaw can potentially lead to remote code execution (RCE) if exploited by authenticated attacker.
CWE-190 - Integer Overflow or Wraparound| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Vulnerability in Apache HTTP Server versions 2.4.0 through 2.4.55. It involves HTTP Request Smuggling due to certain mod_proxy configurations combined with RewriteRule or ProxyPassMatch directives. This flaw can lead to bypassing access controls by an authenticated attacker.
CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Vulnerability in the PKCS#11 feature of ssh-agent in OpenSSH versions before 9.3p2. It involves an insufficiently trustworthy search path, which can lead to remote code execution if an agent is forwarded by authenticated user to an attacker-controlled system.
CWE-428 - Unquoted Search Path or Element| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Untrusted search path vulnerability in ssh-agent.c in ssh-agent in OpenSSH before 7.4 allows remote attackers to execute arbitrary local PKCS#11 modules by leveraging control over a forwarded agent socket.
CWE-426 - Untrusted Search Path| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A use-after-free vulnerability was found in system. This issue occurs due to the on_stream_io() function and dns_stream_complete() function in 'resolved-dns-stream.c' not incrementing the reference counting for the DnsStream object. Therefore, other functions and callbacks called can dereference the DNSStream object, causing the use-after-free when the reference is still used later, allowing authenticated user to execute arbitrary code.
CWE-416 - Use After Free| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field, potentially allowing an authenticated attacker to reveal sensitive information or to cause a denial-of-service situation.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A vulnerability in the HFS+ partition file parser of ClamAV versions 1.0.0 and earlier, 0.105.1 and earlier, and 0.103.7 and earlier could allow an unauthenticated, remote attacker to execute arbitrary code. This vulnerability is due to a missing buffer size check that may result in a heap buffer overflow write. An authenticated attacker could exploit this vulnerability by submitting a crafted HFS+ partition file to be scanned by ClamAV on an affected device.
CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
By spoofing the target resolver with responses that have a malformed ECDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources.
CWE-401 - Missing Release of Memory after Effective Lifetime| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
By spoofing the target resolver with responses that have a malformed EdDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources.
CWE-401 - Missing Release of Memory after Effective Lifetime| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
The vulnerability allows the configured max-cache-size limit to be significantly exceeded by querying the resolver for specific RRsets in a certain order. This can lead to a denial-of-service condition by ex-hausting all available memory on the host running named service.
CWE-770 - Allocation of Resources Without Limits or Throttling| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
The vulnerability involves the recursive processing of control channel messages sent to named, which can exhaust stack memory and cause named to terminate unexpectedly. Exploiting this flaw requires only network access to the control channel's configured TCP port, without needing a valid RNDC key.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Local users able to write to UNIX domain sockets can bypass access controls and manipulate the mul-tipath setup. This can lead to local privilege escalation to root. This occurs because an attacker can repeat a keyword, which is mishandled because arithmetic ADD is used instead of bitwise OR.
CWE-269 - Improper Privilege Management| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Local users can write to UNIX domain sockets can bypass access controls and manipulate the multipath setup. This can lead to local privilege escalation to root. This occurs because an attacker can repeat a keyword, which is mishandled because arithmetic ADD is used instead of bitwise OR.
CWE-416 - Use After Free| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
By feeding specially crafted input as authenticated attacker to `git apply --reject`, a path outside the working tree can be overwritten with partially controlled contents, leading to potential arbitrary code execution.
CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A specially crafted `.gitmodules` file with submodule URLs that are longer than 1024 characters can used to exploit a bug in `config.c::git_config_copy_or_rename_section_in_file()`. This bug can be used to inject arbitrary configuration into a user's `$GIT_DIR/config` when attempting to remove the con-figuration section associated with that submodule. When the attacker injects configuration values which specify executables to run (such as `core.pager`, `core.editor`, `core.sshCommand`, etc.) this can lead to a remote code execution.
CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A flaw was found in the Linux kernel’s driver for the ASIX AX88179_178A-based USB 2.0/3.0 Gigabit Ethernet Devices. The vulnerability contains multiple out-of-bounds reads and possible out-of-bounds writes.
CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Flaw in certain AMD EPYC, Ryzen, Threadripper and Athlon processors considering LONGJMP assembly command. This could lead to arbitrary code execution. Note: ARM600 servers include Intel processors, but there may be ARM600 SW installations running in AMD processor environments.
CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A stack overflow flaw was found in the Linux kernel's SYSCTL subsystem in how an authenticated user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.
CWE-131 - Incorrect Calculation of Buffer Size| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double re-use. This could lead to a system crash or elevation of privileges.
CWE-416 - Use After Free| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A vulnerability classified as critical was found in Linux Kernel. Affected by this vulnerability is the function l2cap_reassemble_sdu of the file net/bluetooth/l2cap_core.c of the component Bluetooth. The manipulation leads to use after free. This could cause leaking of data or Denial of Service (DoS) conditions.
CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
In the Linux kernel through 6.3.1, a use-after-free in Netfilter nf_tables when processing batch requests can be abused to perform arbitrary read and write operations on kernel memory. This could lead to an unprivileged local user gaining root access.
CWE-416 - Use After Free| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace. This vulnerability could lead to local user privilege escalation.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A use-after-free vulnerability in the Linux kernel's net/sched: cls_u32 component can be exploited to achieve local user privilege escalation.
CWE-416 - Use After Free| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
A missing netfilter macro could lead to a miscalculation of the `h->nets` array offset, providing attack-ers with the primitive to arbitrarily increment/decrement a memory buffer out-of-bounds. This vulnerability may allow a local user to crash the system or potentially escalate their privileges.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
PAC parsing in krb5 has integer overflows that may lead to denial of service.
CWE-190 - Integer Overflow or Wraparound| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 | ||
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
An issue was discovered in function _libssh2_packet_add in libssh2 that allows attackers to access out of bounds memory. This could lead to a system crash by authenticated attacker.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. When CRL checking is enabled, this vulnerability may allow an attacker to pass arbitrary pointers to a memcmp call, enabling them to read memory contents or enact a denial of service.
CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
An issue in the urllib.parse component of Python allows attackers to bypass blocklisting methods by supplying a URL that starts with blank characters. Successful exploitation of this vulnerability could lead to addition or modification of data by an authenticated attacker.
CWE-20 - Improper Input Validation| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Remote arbitrary files write inside the directories of connecting peers. A malicious rsync server can overwrite arbitrary files in the rsync client target directory and subdirectories.
CWE-20 - Improper Input Validation| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
The sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This could lead to privilege escalation.
CWE-269 - Improper Privilege Management| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Apache portable runtime utility issue may allow a malicious attacker to cause an out-of-bounds write due to an integer overflow when encoding/decoding a very long string using the base64 family of functions. This could lead to modification of data or denial of service.
CWE-190 - Integer Overflow or Wraparound| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
When using forwarders, bogus NS records supplied by, or via, those forwarders may be cached and used by named if it needs to recurse for any reason, causing it to obtain and pass on potentially incor-rect answers. This could cause DNS cache poisoning that could potentially lead to a denial of service and information disclosure by an authenticated attacker.
CWE-444 - Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Processing large delegations may severely degrade resolver performance effectively denying legitimate clients access to the DNS resolution service. This could cause a denial-of-service conditions.
CWE-400 - Uncontrolled Resource Consumption| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
drivers/usb/mon/mon_bin.c in usbmon in the Linux kernel allows a user-space client to corrupt the monitor's internal memory. This could lead to denial-of-service or information disclosure conditions by an authenticated attacker.
CWE-787 - Out-of-bounds Write| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Return Address Predictor vulnerability leading to information disclosure in certain AMD processors. This may result in speculative execution at an attacker-controlled address, potentially leading to information disclosure. Note: ARM600 servers utilize Intel processors, but there may be ARM600 SW installations running in AMD processor environments.
CWE-203 - Observable Discrepancy| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Cross-Process Information Leak in certain AMD processors. This could lead to an attacker potentially accessing confidential information. Note: ARM600 servers utilize Intel processors, but there may be ARM600 SW installations running in AMD processor environments.
CWE-209 - Generation of Error Message Containing Sensitive Information| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
If a TLS server side socket is created, receives data, and then closes quickly, there's a brief window where the SSLSocket instance detects it as "not connected" and won't initiate a handshake. Buffered data remains readable but unauthenticated if client certificate authentication is expected. This data is limited to the buffer size. An unauthenticated attacker could exploit this vulnerability for revealing sensitive information from the server.
CWE-287 - Improper Authentication| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
Remote attackers may bypass integrity checks such that some packets are omitted (from the extension negotiation message), and a client and server may consequently end up with a connection for which some security features have been downgraded or disabled, aka a Terrapin attack.
CWE-354 - Improper Validation of Integrity Check Value| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
TLS protocol version 1.1 and 1.2 and the DTLS protocol 1.0 and 1.2 do not properly consider timing side-channel attacks on a MAC check requirement during the processing of malformed CBC padding, which allows remote attackers to conduct distinguishing attacks and plaintext-recovery attacks via statistical analysis of timing data for crafted packets, aka the "Lucky Thirteen" issue.
CWE-326 - Inadequate Encryption Strength| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
The TLS protocol 1.2 and earlier can encrypt compressed data without properly obfuscating the length of the unencrypted data, which allows man-in-the-middle attackers to obtain plaintext HTTP headers by observing length differences during a series of guesses in which a string in an HTTP request potentially matches an unknown string in an HTTP header, aka a "CRIME" attack.
CWE-212 - Improper Removal of Sensitive Information Before Storage or Transfer| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
The “ICMP Timestamp Request Remote Date Disclosure” vulnerability involves the use of ICMP (internet Control Message Protocol) to request and receive timestamp information from a target system.
CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ABB M2M Gateway ARM600, firmware versions >=4.1.2|<=5.0.3
ABB / ABB M2M Gateway / ARM600
|
>=4.1.2|<=5.0.3 |
Mitigation
|
|
|
ABB M2M Gateway SW, software versions >=5.0.1|<=5.0.3
ABB / ABB M2M Gateway / SW
|
>=5.0.1|<=5.0.3 |
Mitigation
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "En",
"notes": [
{
"category": "summary",
"text": "ABB is aware of public reports of a vulnerabilities in product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could cause the product to stop, make the product inacces-sible, take remote control of the product or insert and run arbitrary code.\nAs part of ABB product lifecycle policy, once a product transitions to end-of-life, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document, such as using a private APN cellular network between Arctic wireless gateways and ARM600 for establishing VPN tunnels, to mitigate security risks and avoid potential vulnerabilities.\nAs part of ABB product lifecycle policy, once a product transitions to Limited state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document to mitigate security risks.",
"title": "Summary"
},
{
"category": "general",
"text": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n5.\tFilter specific ICMP packets from external systems (ICMP type 13 and 14) by firewall for not exposing the system time. \n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n\n14.\tIn ARM600SW installations, avoid servers with AMD processors vulnerable to the following: CVE-2021-26401, CVE-2023-20569 and CVE-2023-20593.\n\n\n15.\tAvoid using AX88179_178A chipset-based USB -to-Ethernet devices.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"title": "Mitigating factors"
},
{
"category": "other",
"text": "For any installation of software-related ABB products we strongly recommend the following (non-exhaustive) list of cyber security practices:\n\u2013\tIsolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and separate them from any general-purpose network (e.g. office or home networks).\n\u2013\tInstall physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.\n\u2013\tNever connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for.\n\u2013\tScan all data imported into your environment before use to detect potential malware infections.\n\u2013\tMinimize network exposure for all applications and endpoints to ensure that they are not accessible from the internet unless they are designed for such exposure and the intended use requires such.\n\u2013\tEnsure all nodes are always up to date in terms of installed software, operating system, and firmware patches as well as anti-virus and firewall.\n\u2013\tWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nMore information on recommended practices can be found in the following document:\n1MRS758860 Rev. F, Arctic Cyber Security Deployment Guideline\n",
"title": "General security recommendations"
},
{
"category": "other",
"text": "For additional instructions and support please contact your local ABB service organization. For contact information, see www.abb.com/contactcenters.\nInformation about ABB\u2019s cyber security program and capabilities can be found at www.abb.com/cybersecurity.\n",
"title": "Support"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice, and should not be construed as a commitment by ABB.\nABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages.\nThis document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\nAll rights to registrations and trademarks reside with their respective owners.\n",
"title": "Notice"
}
],
"publisher": {
"category": "vendor",
"name": "ABB PSIRT",
"namespace": "https://global.abb/group/en/technology/cyber-security/alerts-and-notifications"
},
"references": [
{
"summary": "Cyber Security Deployment Guideline",
"url": "https://library.e.abb.com/public/ffab1a14a42646c6adee38fc3de61dad/Arctic_csdepl_758860_ENf.pdf"
},
{
"summary": "User Manual",
"url": "https://library.e.abb.com/public/0498e4c0babd46aa9243aedd6f99c375/ARM600_user_758861_ENk.pdf"
},
{
"summary": "ABB product lifecycle policy",
"url": "https://new.abb.com/service/electrification/life-cycle-management?pe_data=D42415F457244415145784545584371%7C29609824"
},
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - PDF version ",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA002579\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
},
{
"summary": "1MRS758860, Rev. F Arctic, Cyber Security Deployment Guideline",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=1MRS758860\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"category": "self",
"summary": "ABB CYBERSECURITY ADVISORY - CSAF version ",
"url": "https://psirt.abb.com/csaf/2025/2nga002579.json"
}
],
"title": "ABB Arctic communication solution ARM600 Vulnerabilities",
"tracking": {
"current_release_date": "2025-04-07T10:30:00.000Z",
"generator": {
"date": "2025-09-23T15:44:30.177Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.35"
}
},
"id": "2NGA002579",
"initial_release_date": "2025-04-07T10:30:00.000Z",
"revision_history": [
{
"date": "2025-04-07T10:30:00.000Z",
"legacy_version": "A",
"number": "1",
"summary": "Initial Version"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=4.1.2|\u003c=5.0.3",
"product": {
"name": "ABB M2M Gateway ARM600, firmware versions \u003e=4.1.2|\u003c=5.0.3",
"product_id": "AV1"
}
}
],
"category": "product_name",
"name": "ARM600"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=5.0.1|\u003c=5.0.3",
"product": {
"name": "ABB M2M Gateway SW, software versions \u003e=5.0.1|\u003c=5.0.3",
"product_id": "AV2"
}
}
],
"category": "product_name",
"name": "SW"
}
],
"category": "product_family",
"name": "ABB M2M Gateway"
}
],
"category": "vendor",
"name": "ABB"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-23521",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "Vulnerability in Git that arises from an issue with git attributes parsing. This flaw can lead to an integer overflow, which might be exploited by authenticated attackers to execute arbitrary code or cause a denial of service.",
"title": "CVE description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-23521",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-23521"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-23521"
},
{
"cve": "CVE-2022-41903",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "Vulnerability in Git that involves a heap overflow in the git archive and git log --format commands. This flaw can potentially lead to remote code execution (RCE) if exploited by authenticated attacker.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-41903",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-41903"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-41903"
},
{
"cve": "CVE-2023-25690",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "description",
"text": "Vulnerability in Apache HTTP Server versions 2.4.0 through 2.4.55. It involves HTTP Request Smuggling\ndue to certain mod_proxy configurations combined with RewriteRule or ProxyPassMatch directives. This\nflaw can lead to bypassing access controls by an authenticated attacker.\n",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-25690",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-25690"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-25690"
},
{
"cve": "CVE-2023-38408",
"cwe": {
"id": "CWE-428",
"name": "Unquoted Search Path or Element"
},
"notes": [
{
"category": "description",
"text": "Vulnerability in the PKCS#11 feature of ssh-agent in OpenSSH versions before 9.3p2. It involves an \ninsufficiently trustworthy search path, which can lead to remote code execution if an agent is \nforwarded by authenticated user to an attacker-controlled system.\n",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD -CVE-2023-38408 ",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-38408"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-38408"
},
{
"cve": "CVE-2016-10009",
"cwe": {
"id": "CWE-426",
"name": "Untrusted Search Path"
},
"notes": [
{
"category": "description",
"text": "Untrusted search path vulnerability in ssh-agent.c in ssh-agent in OpenSSH before 7.4 allows remote\nattackers to execute arbitrary local PKCS#11 modules by leveraging control over a forwarded agent socket.\n",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2016-10009",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2016-10009"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.8,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 5.8,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2016-10009"
},
{
"cve": "CVE-2022-2526",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "A use-after-free vulnerability was found in system. This issue occurs due to the on_stream_io() function and dns_stream_complete() function in \u0027resolved-dns-stream.c\u0027 not incrementing the reference counting for the DnsStream object. Therefore, other functions and callbacks called can dereference the DNSStream object, causing the use-after-free when the reference is still used later, allowing authenticated user to execute arbitrary code.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-2526",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-2526"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "REASONABLE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:R",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-2526"
},
{
"cve": "CVE-2022-37434",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field, potentially allowing an authenticated attacker to reveal sensitive information or to cause a denial-of-service situation.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-37434",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37434"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-37434"
},
{
"cve": "CVE-2023-20032",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "description",
"text": "A vulnerability in the HFS+ partition file parser of ClamAV versions 1.0.0 and earlier, 0.105.1 and earlier, and 0.103.7 and earlier could allow an unauthenticated, remote attacker to execute arbitrary code. This vulnerability is due to a missing buffer size check that may result in a heap buffer overflow write. An authenticated attacker could exploit this vulnerability by submitting a crafted HFS+ partition file to be scanned by ClamAV on an affected device.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-20032",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-20032"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-20032"
},
{
"cve": "CVE-2022-38177",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "description",
"text": "By spoofing the target resolver with responses that have a malformed ECDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2022-38177",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-38177"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-38177"
},
{
"cve": "CVE-2022-38178",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "description",
"text": "By spoofing the target resolver with responses that have a malformed EdDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD -CVE-2022-38178",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-38178"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-38178"
},
{
"cve": "CVE-2023-2828",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "description",
"text": "The vulnerability allows the configured max-cache-size limit to be significantly exceeded by querying the resolver for specific RRsets in a certain order. This can lead to a denial-of-service condition by ex-hausting all available memory on the host running named service.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-2828",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-2828"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-2828"
},
{
"cve": "CVE-2023-3341",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "The vulnerability involves the recursive processing of control channel messages sent to named, which can exhaust stack memory and cause named to terminate unexpectedly. Exploiting this flaw requires only network access to the control channel\u0027s configured TCP port, without needing a valid RNDC key.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-3341",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-3341"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-3341"
},
{
"cve": "CVE-2022-41974",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "description",
"text": "Local users able to write to UNIX domain sockets can bypass access controls and manipulate the mul-tipath setup. This can lead to local privilege escalation to root. This occurs because an attacker can repeat a keyword, which is mishandled because arithmetic ADD is used instead of bitwise OR.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD -CVE-2022-41974",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-41974"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-41974"
},
{
"cve": "CVE-2022-40674",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "Local users can write to UNIX domain sockets can bypass access controls and manipulate the multipath setup. This can lead to local privilege escalation to root. This occurs because an attacker can repeat a keyword, which is mishandled because arithmetic ADD is used instead of bitwise OR.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-40674",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-40674"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-40674"
},
{
"cve": "CVE-2023-25652",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "By feeding specially crafted input as authenticated attacker to `git apply --reject`, a path outside the working tree can be overwritten with partially controlled contents, leading to potential arbitrary code execution.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-25652",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-25652"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-25652"
},
{
"cve": "CVE-2023-29007",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "A specially crafted `.gitmodules` file with submodule URLs that are longer than 1024 characters can used to exploit a bug in `config.c::git_config_copy_or_rename_section_in_file()`. This bug can be used to inject arbitrary configuration into a user\u0027s `$GIT_DIR/config` when attempting to remove the con-figuration section associated with that submodule. When the attacker injects configuration values which specify executables to run (such as `core.pager`, `core.editor`, `core.sshCommand`, etc.) this can lead to a remote code execution.",
"title": "CVE Decsription"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-29007",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-29007"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.7,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.7,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-29007"
},
{
"cve": "CVE-2022-2964",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "A flaw was found in the Linux kernel\u2019s driver for the ASIX AX88179_178A-based USB 2.0/3.0 Gigabit Ethernet Devices. The vulnerability contains multiple out-of-bounds reads and possible out-of-bounds writes.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-2964",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-2964"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n\n15.\tAvoid using AX88179_178A chipset-based USB -to-Ethernet devices.\n\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.7,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.7,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-2964"
},
{
"cve": "CVE-2021-26401",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "Flaw in certain AMD EPYC, Ryzen, Threadripper and Athlon processors considering LONGJMP assembly command. This could lead to arbitrary code execution. Note: ARM600 servers include Intel processors, but there may be ARM600 SW installations running in AMD processor environments.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2021-26401",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-26401"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n\n14.\tIn ARM600SW installations, avoid servers with AMD processors vulnerable to the following: CVE-2021-26401, CVE-2023-20569 and CVE-2023-20593.\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 5.2,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "CHANGED",
"temporalScore": 5.2,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2021-26401"
},
{
"cve": "CVE-2022-4378",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "description",
"text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how an authenticated user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2022-4378",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-4378"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-4378"
},
{
"cve": "CVE-2022-42703",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double re-use. This could lead to a system crash or elevation of privileges.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-42703",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-42703"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 4.1,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 4.1,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-42703"
},
{
"cve": "CVE-2022-3564",
"cwe": {
"id": "CWE-362",
"name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
},
"notes": [
{
"category": "description",
"text": "A vulnerability classified as critical was found in Linux Kernel. Affected by this vulnerability is the function l2cap_reassemble_sdu of the file net/bluetooth/l2cap_core.c of the component Bluetooth. The manipulation leads to use after free. This could cause leaking of data or Denial of Service (DoS) conditions.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - cve-2022-3564",
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-3564"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.3,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-3564"
},
{
"cve": "CVE-2023-32233",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "In the Linux kernel through 6.3.1, a use-after-free in Netfilter nf_tables when processing batch requests can be abused to perform arbitrary read and write operations on kernel memory. This could lead to an unprivileged local user gaining root access.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-32233",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-32233"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-32233"
},
{
"cve": "CVE-2023-35001",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace. This vulnerability could lead to local user privilege escalation.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-35001",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-35001"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-35001"
},
{
"cve": "CVE-2023-3609",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_u32 component can be exploited to achieve local user privilege escalation.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-3609",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-3609"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-3609"
},
{
"cve": "CVE-2023-42753",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A missing netfilter macro could lead to a miscalculation of the `h-\u003enets` array offset, providing attack-ers with the primitive to arbitrarily increment/decrement a memory buffer out-of-bounds. This vulnerability may allow a local user to crash the system or potentially escalate their privileges.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-42753",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-42753"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-42753"
},
{
"cve": "CVE-2022-42898",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "PAC parsing in krb5 has integer overflows that may lead to denial of service.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - cve-2022-42898",
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42898"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-42898"
},
{
"cve": "CVE-2020-22218",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "An issue was discovered in function _libssh2_packet_add in libssh2 that allows attackers to access out of bounds memory. This could lead to a system crash by authenticated attacker.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2020-22218",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-22218"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2020-22218"
},
{
"cve": "CVE-2023-0286",
"cwe": {
"id": "CWE-843",
"name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
},
"notes": [
{
"category": "description",
"text": "X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. When CRL checking is enabled, this vulnerability may allow an attacker to pass arbitrary pointers to a memcmp call, enabling them to read memory contents or enact a denial of service.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-0286",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-0286"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 5.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 5.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-0286"
},
{
"cve": "CVE-2023-24329",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "An issue in the urllib.parse component of Python allows attackers to bypass blocklisting methods by supplying a URL that starts with blank characters. Successful exploitation of this vulnerability could lead to addition or modification of data by an authenticated attacker.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-24329",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-24329"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-24329"
},
{
"cve": "CVE-2022-29154",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "Remote arbitrary files write inside the directories of connecting peers. A malicious rsync server can overwrite arbitrary files in the rsync client target directory and subdirectories.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2022-29154",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-29154"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.3,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-29154"
},
{
"cve": "CVE-2023-22809",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "description",
"text": "The sudoedit (aka -e) feature mishandles extra arguments passed in the user-provided environment variables (SUDO_EDITOR, VISUAL, and EDITOR), allowing a local attacker to append arbitrary entries to the list of files to process. This could lead to privilege escalation.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-22809",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-22809"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-22809"
},
{
"cve": "CVE-2022-25147",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "Apache portable runtime utility issue may allow a malicious attacker to cause an out-of-bounds write due to an integer overflow when encoding/decoding a very long string using the base64 family of functions. This could lead to modification of data or denial of service.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-25147",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-25147"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-25147"
},
{
"cve": "CVE-2021-25220",
"cwe": {
"id": "CWE-444",
"name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)"
},
"notes": [
{
"category": "description",
"text": "When using forwarders, bogus NS records supplied by, or via, those forwarders may be cached and used by named if it needs to recurse for any reason, causing it to obtain and pass on potentially incor-rect answers. This could cause DNS cache poisoning that could potentially lead to a denial of service and information disclosure by an authenticated attacker.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2021-25220",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-25220"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.3,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "CHANGED",
"temporalScore": 6.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2021-25220"
},
{
"cve": "CVE-2022-2795",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "description",
"text": "Processing large delegations may severely degrade resolver performance effectively denying legitimate clients access to the DNS resolution service. This could cause a denial-of-service conditions.",
"title": "CVE Descritpion"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2022-2795",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-2795"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n3.\tARM600 system is by default not dependent on the name service (DNS). If name service is not used in the system, the name service port (TCP/UDP port 53) can be blocked by a firewall.\n\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"environmentalScore": 2.5,
"environmentalSeverity": "LOW",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 2.5,
"temporalSeverity": "LOW",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-2795"
},
{
"cve": "CVE-2022-43750",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "drivers/usb/mon/mon_bin.c in usbmon in the Linux kernel allows a user-space client to corrupt the monitor\u0027s internal memory. This could lead to denial-of-service or information disclosure conditions by an authenticated attacker.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2022-43750",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43750"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.2,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6.2,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2022-43750"
},
{
"cve": "CVE-2023-20569",
"cwe": {
"id": "CWE-203",
"name": "Observable Discrepancy"
},
"notes": [
{
"category": "description",
"text": "Return Address Predictor vulnerability leading to information disclosure in certain AMD processors. This may result in speculative execution at an attacker-controlled\u202faddress, potentially leading to information disclosure. Note: ARM600 servers utilize Intel processors, but there may be ARM600 SW installations running in AMD processor environments.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-20569",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-20569"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n\n14.\tIn ARM600SW installations, avoid servers with AMD processors vulnerable to the following: CVE-2021-26401, CVE-2023-20569 and CVE-2023-20593.\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-20569"
},
{
"cve": "CVE-2023-20593",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "description",
"text": "Cross-Process Information Leak in certain AMD processors. This could lead to an attacker potentially accessing confidential information. Note: ARM600 servers utilize Intel processors, but there may be ARM600 SW installations running in AMD processor environments.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2023-20593",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-20593"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 5.1,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 5.1,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-20593"
},
{
"cve": "CVE-2023-40217",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "description",
"text": "If a TLS server side socket is created, receives data, and then closes quickly, there\u0027s a brief window where the SSLSocket instance detects it as \"not connected\" and won\u0027t initiate a handshake. Buffered data remains readable but unauthenticated if client certificate authentication is expected. This data is limited to the buffer size. An unauthenticated attacker could exploit this vulnerability for revealing sensitive information from the server.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-40217",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40217"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 4.9,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 4.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-40217"
},
{
"cve": "CVE-2023-48795",
"cwe": {
"id": "CWE-354",
"name": "Improper Validation of Integrity Check Value"
},
"notes": [
{
"category": "description",
"text": "Remote attackers may bypass integrity checks such that some packets are omitted (from the extension negotiation message), and a client and server may consequently end up with a connection for which some security features have been downgraded or disabled, aka a Terrapin attack.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2023-48795",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48795"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.4,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 5.4,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2023-48795"
},
{
"cve": "CVE-2013-0169",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"category": "description",
"text": "TLS protocol version 1.1 and 1.2 and the DTLS protocol 1.0 and 1.2 do not properly consider timing side-channel attacks on a MAC check requirement during the processing of malformed CBC padding, which allows remote attackers to conduct distinguishing attacks and plaintext-recovery attacks via statistical analysis of timing data for crafted packets, aka the \"Lucky Thirteen\" issue.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD- CVE-2013-0169",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0169"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2013-0169"
},
{
"cve": "CVE-2012-4929",
"cwe": {
"id": "CWE-212",
"name": "Improper Removal of Sensitive Information Before Storage or Transfer"
},
"notes": [
{
"category": "description",
"text": "The TLS protocol 1.2 and earlier can encrypt compressed data without properly obfuscating the length of the unencrypted data, which allows man-in-the-middle attackers to obtain plaintext HTTP headers by observing length differences during a series of guesses in which a string in an HTTP request potentially matches an unknown string in an HTTP header, aka a \"CRIME\" attack.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD-CVE-2012-4929",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2012-4929"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n1.\tObtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn\u2019t expose the traffic between remote sites and main site to the internet but rather uses cellular operator\u2019s private wide area network (WAN). Therefore, the ARM600 wouldn\u2019t need open ports to the internet.\n\n2.\tAvoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client).\n\n4.\tPerform firewall configuration by the \"allowlisting\" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic.\n\n\n6.\tIf the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ).\n\n7.\tChange the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system.\n\n\n8.\tUse administrator (i.e., root user) privileges only when required by the task.\n\n\n9.\tSupporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. \n\nAny data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring.\n\n\n10.\tIntroduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following:\na.\tCheck that the entire system has backups available from all applicable parts.\nb.\tStore the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms.\nc.\tEnsure the security of the configuration PCs that may have local copies of device configurations.\nd.\tValidate the backups to make sure that they\u2019re working.\n\n\n11.\tFollow cyber security best practices for installation, operation, and decommissioning as described in the product\u2019s Cyber Security Deployment Guideline and User Manual.\n\n\n12.\tUse continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system\n\n\n13.\tConsider hardening the system according to the following:\na.\tRemove any unnecessary communication links in the system.\nb.\tIf possible, close unused physical ports.\nc.\tOpen only the necessary TCP/UDP ports in the configuration.\nd.\tRemove all unnecessary user accounts.\ne.\tRestrict traffic by firewall.\nf.\tAllow the traffic only from/to necessary hosts\u0027 IP addresses (i.e., define both source and destination in the firewall rules, where possible).\ng.\tDefine client IP address as allowed address in SCADA communication protocols, if such configuration is supported.\nh.\tRemove or deactivate all unused processes, communication ports and services, where possible.\ni.\tUse physical access controls to the system installations (e.g., to server rooms and device cabinets). \n\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"environmentalScore": 3.4,
"environmentalSeverity": "LOW",
"exploitCodeMaturity": "PROOF_OF_CONCEPT",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "WORKAROUND",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 3.4,
"temporalSeverity": "LOW",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-2012-4929"
},
{
"cve": "CVE-1999-0524",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "description",
"text": "The \u201cICMP Timestamp Request Remote Date Disclosure\u201d vulnerability involves the use of ICMP (internet Control Message Protocol) to request and receive timestamp information from a target system.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"AV1",
"AV2"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-1999-0524",
"url": "https://nvd.nist.gov/vuln/detail/CVE-1999-0524"
}
],
"remediations": [
{
"category": "mitigation",
"details": "\nMitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended.\n\n5.\tFilter specific ICMP packets from external systems (ICMP type 13 and 14) by firewall for not exposing the system time.\n\nRefer to section General security recommendations for additional advice on how to keep your system secure.\n",
"product_ids": [
"AV1",
"AV2"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5,
"environmentalSeverity": "MEDIUM",
"exploitCodeMaturity": "FUNCTIONAL",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "TEMPORARY_FIX",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:T/RC:C",
"version": "3.1"
},
"products": [
"AV1",
"AV2"
]
}
],
"title": "CVE-1999-0524"
}
]
}
CERTFR-2023-AVI-0043
Vulnerability from certfr_avis - Published: - Updated:
Une vulnérabilité a été découverte dans sudo. Elle permet à un attaquant de provoquer un contournement de la politique de sécurité et une élévation de privilèges.
La vulnérabilité est induite par un manquement dans la vérification de l'argument paramétrant l'éditeur texte de l'utilisateur.
Solution
La vulnérabilité est corrigée dans la version sudo 1.9.12p2. Le déploiement de ce correctif sera réalisé selon le rythme de cycle de mise à jour de sécurité de chaque distribution. Il est conseillé de se référer aux bulletins de sécurité des éditeurs de distribution Unix, Linux et Mac.
La mise à jour d'un produit ou d'un logiciel est une opération délicate qui doit être menée avec prudence. Il est notamment recommander d'effectuer des tests autant que possible. Des dispositions doivent également être prises pour garantir la continuité de service en cas de difficultés lors de l'application des mises à jour comme des correctifs ou des changements de version.
Contournement provisoire
Il est possible d'empêcher l'utilisation d'un éditeur de texte spécifié par l'utilisateur lors de l'exécution de commande sudoedit en ajoutant les lignes suivantes dans le fichier sudoers :
Defaults!sudoedit env_delete+="SUDO_EDITOR VISUAL EDITOR"
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des détails sur la correction (cf. section Documentation).
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Sudo versions 1.8.x et 1.9.x ant\u00e9rieures \u00e0 1.9.12p2",
"product": {
"name": "Sudo",
"vendor": {
"name": "Sudo",
"scada": false
}
}
}
],
"affected_systems_content": "",
"content": "## Solution\n\nLa vuln\u00e9rabilit\u00e9 est corrig\u00e9e dans la version sudo 1.9.12p2. Le\nd\u00e9ploiement de ce correctif sera r\u00e9alis\u00e9 selon le rythme de cycle de\nmise \u00e0 jour de s\u00e9curit\u00e9 de chaque distribution. Il est conseill\u00e9 de se\nr\u00e9f\u00e9rer aux bulletins de s\u00e9curit\u00e9 des \u00e9diteurs de distribution Unix,\nLinux et Mac.\n\nLa mise \u00e0\u00a0jour d\u0027un produit ou d\u0027un logiciel est une op\u00e9ration d\u00e9licate\nqui doit \u00eatre men\u00e9e avec prudence. Il est notamment recommander\nd\u0027effectuer des tests autant que possible. Des dispositions doivent\n\u00e9galement \u00eatre prises pour garantir la continuit\u00e9 de service en cas de\ndifficult\u00e9s lors de l\u0027application des mises \u00e0 jour comme des correctifs\nou des changements de version.\n\n## Contournement provisoire\n\nIl est possible d\u0027emp\u00eacher l\u0027utilisation d\u0027un \u00e9diteur de texte sp\u00e9cifi\u00e9\npar l\u0027utilisateur lors de l\u0027ex\u00e9cution de commande *sudoedit* en ajoutant\nles lignes suivantes dans le fichier *sudoers* :\n\n`Defaults!sudoedit env_delete+=\"SUDO_EDITOR VISUAL EDITOR\"`\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\nd\u00e9tails sur la correction (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0043",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-01-20T00:00:00.000000"
}
],
"risks": [
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "Une vuln\u00e9rabilit\u00e9 a \u00e9t\u00e9 d\u00e9couverte dans sudo. Elle permet \u00e0 un attaquant\nde provoquer un contournement de la politique de s\u00e9curit\u00e9 et une\n\u00e9l\u00e9vation de privil\u00e8ges.\n\nLa vuln\u00e9rabilit\u00e9 est induite par un manquement dans la v\u00e9rification de\nl\u0027argument param\u00e9trant l\u0027\u00e9diteur texte de l\u0027utilisateur.\n",
"title": "Vuln\u00e9rabilit\u00e9 dans Sudo",
"vendor_advisories": [
{
"published_at": "2023-01-18",
"title": "Bulletin de s\u00e9curit\u00e9 Sudo",
"url": "https://www.sudo.ws/security/advisories/sudoedit_any/"
}
]
}
CERTFR-2023-AVI-0258
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits IBM. Elles permettent à un attaquant de provoquer un contournement de la politique de sécurité, une élévation de privilèges, un déni de service à distance, une atteinte à la confidentialité des données, une injection de code indirecte à distance (XSS) et une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| IBM | Spectrum | IBM Spectrum Protect Client versions 8.1.x antérieures à 8.1.17.2 | ||
| IBM | WebSphere | IBM WebSphere Remote Server version 9.0 déployée avec une version de IBM WebSphere Application Server antérieure à 9.0.5.14 incluant le correctif PH52925 | ||
| IBM | Spectrum | IBM Spectrum Protect Plus versions 10.1.x antérieures à 10.1.14 |
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IBM Spectrum Protect Client versions 8.1.x ant\u00e9rieures \u00e0 8.1.17.2",
"product": {
"name": "Spectrum",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM WebSphere Remote Server version 9.0 d\u00e9ploy\u00e9e avec une version de IBM WebSphere Application Server ant\u00e9rieure \u00e0 9.0.5.14 incluant le correctif PH52925",
"product": {
"name": "WebSphere",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Spectrum Protect Plus versions 10.1.x ant\u00e9rieures \u00e0 10.1.14",
"product": {
"name": "Spectrum",
"vendor": {
"name": "IBM",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0216"
},
{
"name": "CVE-2023-0401",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0401"
},
{
"name": "CVE-2023-26283",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26283"
},
{
"name": "CVE-2022-32190",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32190"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2022-4269",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4269"
},
{
"name": "CVE-2022-41715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41715"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2019-20444",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20444"
},
{
"name": "CVE-2022-2601",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2601"
},
{
"name": "CVE-2022-4203",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4203"
},
{
"name": "CVE-2022-2421",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2421"
},
{
"name": "CVE-2022-1016",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1016"
},
{
"name": "CVE-2023-0217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0217"
},
{
"name": "CVE-2022-43552",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43552"
},
{
"name": "CVE-2023-23915",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23915"
},
{
"name": "CVE-2022-41716",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41716"
},
{
"name": "CVE-2022-0854",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0854"
},
{
"name": "CVE-2022-28893",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28893"
},
{
"name": "CVE-2023-23914",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23914"
},
{
"name": "CVE-2023-27863",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27863"
},
{
"name": "CVE-2022-41717",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41717"
},
{
"name": "CVE-2022-2047",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2047"
},
{
"name": "CVE-2022-43945",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43945"
},
{
"name": "CVE-2022-2880",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2880"
},
{
"name": "CVE-2018-10237",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-10237"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2022-3996",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3996"
},
{
"name": "CVE-2022-2879",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2879"
},
{
"name": "CVE-2022-43551",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43551"
},
{
"name": "CVE-2022-43548",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43548"
},
{
"name": "CVE-2022-2588",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2588"
},
{
"name": "CVE-2022-4139",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4139"
},
{
"name": "CVE-2022-27664",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27664"
},
{
"name": "CVE-2023-23916",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23916"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0258",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-03-24T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits \u003cspan\nclass=\"textit\"\u003eIBM\u003c/span\u003e. Elles permettent \u00e0 un attaquant de provoquer\nun contournement de la politique de s\u00e9curit\u00e9, une \u00e9l\u00e9vation de\nprivil\u00e8ges, un d\u00e9ni de service \u00e0 distance, une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es, une injection de code indirecte \u00e0 distance\n(XSS) et une ex\u00e9cution de code arbitraire \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits IBM",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6963786 du 23 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6963786"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6965816 du 23 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6965816"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6965812 du 23 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6965812"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6965822 du 23 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6965822"
}
]
}
CERTFR-2023-AVI-0271
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Qnap. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une atteinte à la confidentialité des données et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "QTS versions 5.0.x ant\u00e9rieures \u00e0 5.0.1.2346 build 20230322",
"product": {
"name": "QTS",
"vendor": {
"name": "Qnap",
"scada": false
}
}
},
{
"description": "QuTS hero h5.0.x ant\u00e9rieures \u00e0 h5.0.1.2348 build 20230324",
"product": {
"name": "QuTS hero",
"vendor": {
"name": "Qnap",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2022-3437",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3437"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2022-42898",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42898"
},
{
"name": "CVE-2022-3592",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3592"
},
{
"name": "CVE-2022-27597",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27597"
},
{
"name": "CVE-2022-27598",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27598"
},
{
"name": "CVE-2023-23355",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23355"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0271",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-03-30T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits \u003cspan\nclass=\"textit\"\u003eQnap\u003c/span\u003e. Elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es et un contournement de la politique de\ns\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Qnap",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-06 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-10 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-10"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-03 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-15 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-15"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-11 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-11"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Qnap QSA-23-02 du 30 mars 2023",
"url": "https://www.qnap.com/fr-fr/security-advisory/qsa-23-02"
}
]
}
CERTFR-2023-AVI-0276
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans IBM. Elles permettent à un attaquant de provoquer une atteinte à la confidentialité des données, une élévation de privilèges, une atteinte à l'intégrité des données, un contournement de la politique de sécurité, une injection de code indirecte à distance (XSS), une exécution de code arbitraire à distance, un déni de service à distance et un problème de sécurité non spécifié par l'éditeur.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| IBM | WebSphere | IBM WebSphere Hybrid Edition 5.1 sans le correctif de sécurité APAR PH52925 | ||
| IBM | WebSphere | IBM WebSphere Automation versions antérieures à 1.5.2 | ||
| IBM | WebSphere | IBM WebSphere Application Server 9.0 sans le correctif de sécurité APAR PH52925 | ||
| IBM | QRadar SIEM | IBM QRadar SIEM versions antérieures à 7.5.0 UP5 | ||
| IBM | Db2 | IBM Db2 Web Queryfor i versions 2.3.0 et 2.4.0 sans le correctif de sécurité 5733WQX | ||
| IBM | Spectrum | IBM Spectrum Protect Plus Server versions antérieures à 10.1.12.4 | ||
| IBM | N/A | IBM HTTP Server for i sans le correctif de sécurité 5770DG1 | ||
| IBM | QRadar SIEM | IBM QRadar SIEM versions antérieures à 7.5.0 UP4 IF01 | ||
| IBM | QRadar User Behavior Analytics | QRadar User Behavior Analytics versions 1.0.0 à 4.1.10 antérieures à 4.1.11 | ||
| IBM | QRadar SIEM | IBM QRadar SIEM versions antérieures à 7.4.3 FP9 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IBM WebSphere Hybrid Edition 5.1 sans le correctif de s\u00e9curit\u00e9 APAR PH52925",
"product": {
"name": "WebSphere",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM WebSphere Automation versions ant\u00e9rieures \u00e0 1.5.2",
"product": {
"name": "WebSphere",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM WebSphere Application Server 9.0 sans le correctif de s\u00e9curit\u00e9 APAR PH52925",
"product": {
"name": "WebSphere",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM QRadar SIEM versions ant\u00e9rieures \u00e0 7.5.0 UP5",
"product": {
"name": "QRadar SIEM",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 Web Queryfor i versions 2.3.0 et 2.4.0 sans le correctif de s\u00e9curit\u00e9 5733WQX",
"product": {
"name": "Db2",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Spectrum Protect Plus Server versions ant\u00e9rieures \u00e0 10.1.12.4",
"product": {
"name": "Spectrum",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM HTTP Server for i sans le correctif de s\u00e9curit\u00e9 5770DG1",
"product": {
"name": "N/A",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM QRadar SIEM versions ant\u00e9rieures \u00e0 7.5.0 UP4 IF01",
"product": {
"name": "QRadar SIEM",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "QRadar User Behavior Analytics versions 1.0.0 \u00e0 4.1.10 ant\u00e9rieures \u00e0 4.1.11",
"product": {
"name": "QRadar User Behavior Analytics",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM QRadar SIEM versions ant\u00e9rieures \u00e0 7.4.3 FP9",
"product": {
"name": "QRadar SIEM",
"vendor": {
"name": "IBM",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-28733",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28733"
},
{
"name": "CVE-2022-31129",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31129"
},
{
"name": "CVE-2022-32189",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32189"
},
{
"name": "CVE-2020-24025",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24025"
},
{
"name": "CVE-2021-21409",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21409"
},
{
"name": "CVE-2023-26283",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26283"
},
{
"name": "CVE-2022-30631",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30631"
},
{
"name": "CVE-2022-23825",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23825"
},
{
"name": "CVE-2021-39227",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39227"
},
{
"name": "CVE-2021-23364",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23364"
},
{
"name": "CVE-2022-22971",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22971"
},
{
"name": "CVE-2021-37701",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37701"
},
{
"name": "CVE-2021-25220",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25220"
},
{
"name": "CVE-2022-2964",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2964"
},
{
"name": "CVE-2021-3677",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3677"
},
{
"name": "CVE-2018-19797",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-19797"
},
{
"name": "CVE-2021-32804",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32804"
},
{
"name": "CVE-2018-19827",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-19827"
},
{
"name": "CVE-2018-15494",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15494"
},
{
"name": "CVE-2022-30635",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30635"
},
{
"name": "CVE-2018-11694",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11694"
},
{
"name": "CVE-2022-41715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41715"
},
{
"name": "CVE-2022-37603",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37603"
},
{
"name": "CVE-2018-8036",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-8036"
},
{
"name": "CVE-2022-25647",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25647"
},
{
"name": "CVE-2022-29900",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29900"
},
{
"name": "CVE-2022-29901",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29901"
},
{
"name": "CVE-2022-36364",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36364"
},
{
"name": "CVE-2022-4883",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4883"
},
{
"name": "CVE-2022-41966",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41966"
},
{
"name": "CVE-2022-21624",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21624"
},
{
"name": "CVE-2020-13936",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13936"
},
{
"name": "CVE-2022-30629",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30629"
},
{
"name": "CVE-2022-40153",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40153"
},
{
"name": "CVE-2022-42252",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42252"
},
{
"name": "CVE-2022-32148",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32148"
},
{
"name": "CVE-2022-40149",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40149"
},
{
"name": "CVE-2022-21626",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21626"
},
{
"name": "CVE-2020-7764",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7764"
},
{
"name": "CVE-2022-41946",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41946"
},
{
"name": "CVE-2022-25927",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25927"
},
{
"name": "CVE-2022-30630",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30630"
},
{
"name": "CVE-2021-37713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37713"
},
{
"name": "CVE-2021-42581",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42581"
},
{
"name": "CVE-2022-1705",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1705"
},
{
"name": "CVE-2021-37137",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37137"
},
{
"name": "CVE-2021-37712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37712"
},
{
"name": "CVE-2022-21724",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21724"
},
{
"name": "CVE-2022-46364",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46364"
},
{
"name": "CVE-2022-40150",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40150"
},
{
"name": "CVE-2022-24999",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24999"
},
{
"name": "CVE-2022-30633",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30633"
},
{
"name": "CVE-2019-10785",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10785"
},
{
"name": "CVE-2022-21628",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21628"
},
{
"name": "CVE-2022-24823",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24823"
},
{
"name": "CVE-2021-37136",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37136"
},
{
"name": "CVE-2022-30632",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30632"
},
{
"name": "CVE-2022-37601",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37601"
},
{
"name": "CVE-2022-40152",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40152"
},
{
"name": "CVE-2021-3807",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3807"
},
{
"name": "CVE-2022-46363",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46363"
},
{
"name": "CVE-2021-21295",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21295"
},
{
"name": "CVE-2022-1962",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1962"
},
{
"name": "CVE-2021-23382",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23382"
},
{
"name": "CVE-2019-6286",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6286"
},
{
"name": "CVE-2022-2795",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2795"
},
{
"name": "CVE-2020-5259",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-5259"
},
{
"name": "CVE-2022-28131",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28131"
},
{
"name": "CVE-2021-26401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26401"
},
{
"name": "CVE-2022-24785",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24785"
},
{
"name": "CVE-2021-23450",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23450"
},
{
"name": "CVE-2018-19839",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-19839"
},
{
"name": "CVE-2021-43797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-43797"
},
{
"name": "CVE-2021-32803",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32803"
},
{
"name": "CVE-2022-4254",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4254"
},
{
"name": "CVE-2022-2880",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2880"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2018-20821",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20821"
},
{
"name": "CVE-2022-45143",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45143"
},
{
"name": "CVE-2022-26373",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26373"
},
{
"name": "CVE-2022-2879",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2879"
},
{
"name": "CVE-2019-6283",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6283"
},
{
"name": "CVE-2019-6284",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6284"
},
{
"name": "CVE-2022-42898",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42898"
},
{
"name": "CVE-2022-25901",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25901"
},
{
"name": "CVE-2020-15366",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15366"
},
{
"name": "CVE-2022-22970",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22970"
},
{
"name": "CVE-2022-1552",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1552"
},
{
"name": "CVE-2022-3676",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3676"
},
{
"name": "CVE-2022-42890",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42890"
},
{
"name": "CVE-2022-23437",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23437"
},
{
"name": "CVE-2022-34917",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34917"
},
{
"name": "CVE-2021-23343",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23343"
},
{
"name": "CVE-2022-2588",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2588"
},
{
"name": "CVE-2022-43928",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43928"
},
{
"name": "CVE-2021-42740",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42740"
},
{
"name": "CVE-2021-3918",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3918"
},
{
"name": "CVE-2018-20190",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20190"
},
{
"name": "CVE-2022-30580",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30580"
},
{
"name": "CVE-2021-21290",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21290"
},
{
"name": "CVE-2022-40156",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40156"
},
{
"name": "CVE-2022-2625",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2625"
},
{
"name": "CVE-2022-40155",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40155"
},
{
"name": "CVE-2022-23816",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23816"
},
{
"name": "CVE-2022-31197",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31197"
},
{
"name": "CVE-2018-19838",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-19838"
},
{
"name": "CVE-2022-37599",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37599"
},
{
"name": "CVE-2021-23368",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23368"
},
{
"name": "CVE-2018-11698",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11698"
},
{
"name": "CVE-2021-29060",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29060"
},
{
"name": "CVE-2022-36033",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36033"
},
{
"name": "CVE-2021-3765",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3765"
},
{
"name": "CVE-2022-25758",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25758"
},
{
"name": "CVE-2021-23362",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23362"
},
{
"name": "CVE-2022-21619",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21619"
},
{
"name": "CVE-2022-37598",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37598"
},
{
"name": "CVE-2022-24839",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24839"
},
{
"name": "CVE-2022-40154",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40154"
},
{
"name": "CVE-2022-41704",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41704"
},
{
"name": "CVE-2022-27664",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27664"
}
],
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967365 du 20 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967365"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967333 du 30 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967333"
}
],
"reference": "CERTFR-2023-AVI-0276",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-03-31T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eIBM\u003c/span\u003e. Elles permettent \u00e0 un attaquant de provoquer\nune atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es, une \u00e9l\u00e9vation de\nprivil\u00e8ges, une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es, un contournement de\nla politique de s\u00e9curit\u00e9, une injection de code indirecte \u00e0 distance\n(XSS), une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits IBM",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967016 du 29 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967016"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967283 du 15 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967283"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967333 du 20 mars 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967285 du 28 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967285"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6966998 du 29 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6966998"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967315 du 30 mars 2023",
"url": "https://www.ibm.com/support/pages/node/6967315"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 6967365 du 30 mars 2023",
"url": null
}
]
}
CERTFR-2023-AVI-0318
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans VMware. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| VMware | N/A | Isolation Segment versions 2.12.x antérieures à 2.12.19 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.12.x antérieures à 2.12.24 | ||
| VMware | N/A | Canonical Ubuntu 18.04 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.13.x antérieures à 2.13.17 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.0.x antérieures à to 4.0.13 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.11.x antérieures à 2.11.35 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.3.x versions antérieures à 4.3.5 | ||
| VMware | N/A | Platform Automation Toolkit versions 5.1.x versions antérieures à 5.1.0 | ||
| VMware | N/A | Operations Manager versions 3.0.x antérieures à 3.0.4 | ||
| VMware | N/A | Operations Manager versions 2.10.x antérieures à 2.10.51 | ||
| VMware | N/A | Isolation Segment versions 3.0.x antérieures à 3.0.7 (avec Jammy Stemcells versions antérieures à 1.80) | ||
| VMware | N/A | Isolation Segment versions 2.11.x antérieures à 2.11.29 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.2.x antérieures à 4.2.8 | ||
| VMware | N/A | Canonical Ubuntu 16.04 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.4.x versions antérieures à 4.4.30 | ||
| VMware | N/A | Canonical Ubuntu 22.04 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 3.0.x antérieures à 3.0.7 (avec Jammy Stemcells versions 1.80) | ||
| VMware | N/A | Platform Automation Toolkit versions 5.0.x versions antérieures à 5.0.23 | ||
| VMware | N/A | Isolation Segment versions 2.13.x antérieures à 2.13.14 | ||
| VMware | Tanzu | Tanzu Greenplum for Kubernetes versions antérieures à 1.4.0 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.1.x antérieures à 4.1.13 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Isolation Segment versions 2.12.x ant\u00e9rieures \u00e0 2.12.19",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.12.x ant\u00e9rieures \u00e0 2.12.24",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 18.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.13.x ant\u00e9rieures \u00e0 2.13.17",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.0.x ant\u00e9rieures \u00e0 to 4.0.13",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.11.x ant\u00e9rieures \u00e0 2.11.35",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.3.x versions ant\u00e9rieures \u00e0 4.3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 5.1.x versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Operations Manager versions 3.0.x ant\u00e9rieures \u00e0 3.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Operations Manager versions 2.10.x ant\u00e9rieures \u00e0 2.10.51",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 3.0.x ant\u00e9rieures \u00e0 3.0.7 (avec Jammy Stemcells versions ant\u00e9rieures \u00e0 1.80)",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 2.11.x ant\u00e9rieures \u00e0 2.11.29",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.2.x ant\u00e9rieures \u00e0 4.2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 16.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.4.x versions ant\u00e9rieures \u00e0 4.4.30",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 22.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 3.0.x ant\u00e9rieures \u00e0 3.0.7 (avec Jammy Stemcells versions 1.80)",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 5.0.x versions ant\u00e9rieures \u00e0 5.0.23",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 2.13.x ant\u00e9rieures \u00e0 2.13.14",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Tanzu Greenplum for Kubernetes versions ant\u00e9rieures \u00e0 1.4.0",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.1.x ant\u00e9rieures \u00e0 4.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-24809",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24809"
},
{
"name": "CVE-2022-47629",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47629"
},
{
"name": "CVE-2022-24805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24805"
},
{
"name": "CVE-2022-44792",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44792"
},
{
"name": "CVE-2022-45061",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45061"
},
{
"name": "CVE-2022-4883",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4883"
},
{
"name": "CVE-2022-44793",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44793"
},
{
"name": "CVE-2022-3165",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3165"
},
{
"name": "CVE-2022-0417",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0417"
},
{
"name": "CVE-2022-24807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24807"
},
{
"name": "CVE-2022-24810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24810"
},
{
"name": "CVE-2022-37454",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37454"
},
{
"name": "CVE-2022-44617",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44617"
},
{
"name": "CVE-2021-3682",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3682"
},
{
"name": "CVE-2021-23222",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23222"
},
{
"name": "CVE-2022-2962",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2962"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2022-0392",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0392"
},
{
"name": "CVE-2022-33070",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33070"
},
{
"name": "CVE-2022-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0216"
},
{
"name": "CVE-2022-40898",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40898"
},
{
"name": "CVE-2022-24806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24806"
},
{
"name": "CVE-2022-46285",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46285"
},
{
"name": "CVE-2021-3930",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3930"
},
{
"name": "CVE-2021-33621",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33621"
},
{
"name": "CVE-2022-24808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24808"
},
{
"name": "CVE-2021-3750",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3750"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0318",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-04-17T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eVMware\u003c/span\u003e. Elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de\nprivil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits VMware",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5795-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5787-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5795-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5787-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5772-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5765-1 du 13 avril 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5821-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5821-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5801-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5795-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5811-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5811-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5767-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5806-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5801-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5807-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5807-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-1 du 12 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5765-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5806-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5806-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5772-1 du 13 avril 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5767-1 du 13 avril 2023",
"url": null
}
]
}
CERTFR-2023-AVI-0816
Vulnerability from certfr_avis - Published: - Updated:
Une vulnérabilité a été découverte dans les produits Synology. Elle permet à un attaquant de provoquer une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Synology SRM 1.3 toutes versions",
"product": {
"name": "SRM",
"vendor": {
"name": "Synology",
"scada": false
}
}
},
{
"description": "Synology VS firmware 3.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Synology",
"scada": false
}
}
},
{
"description": "Synology DSMUC 3.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Synology",
"scada": false
}
}
},
{
"description": "Synology DSM 6.2, 7.0, 7.1 versions ant\u00e9rieures \u00e0 7.2.1-69057",
"product": {
"name": "DSM",
"vendor": {
"name": "Synology",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0816",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-10-09T00:00:00.000000"
}
],
"risks": [
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "Une vuln\u00e9rabilit\u00e9 a \u00e9t\u00e9 d\u00e9couverte dans \u003cspan class=\"textit\"\u003eles\nproduits Synology\u003c/span\u003e. Elle permet \u00e0 un attaquant de provoquer une\n\u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Vuln\u00e9rabilit\u00e9 dans les produits Synology",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Synology-SA-23:02 du 04 octobre 2023",
"url": "https://www.synology.com/fr-fr/security/advisory/Synology_SA_23_02"
}
]
}
CERTFR-2023-AVI-0839
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits IBM. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une atteinte à la confidentialité des données et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| IBM | Sterling | IBM Sterling Order Management versions 10.0.x antérieures à 10.0.2309.0 | ||
| IBM | N/A | IBM Db2 on Cloud Pak for Data versions 3.5, 4.0, 4.5, 4.6, 4.7 antérieures à 4.7 Refresh 3 | ||
| IBM | Db2 | IBM Db2 versions 10.5.0.x sans les derniers correctifs de sécurité | ||
| IBM | Db2 | IBM Db2 versions 11.1.4.x sans les derniers correctifs de sécurité | ||
| IBM | Db2 | IBM Db2 REST versions 1.0.0.121-amd64 à 1.0.0.276-amd64 antérieures à 1.0.0.291-amd64 | ||
| IBM | N/A | IBM Db2 Warehouse on Cloud Pak for Data versions 3.5, 4.0, 4.5, 4.6, 4.7 antérieures à 4.7 Refresh 3 | ||
| IBM | Db2 | IBM Db2 versions 11.5.x sans les derniers correctifs de sécurité | ||
| IBM | QRadar | IBM QRadar Network Packet Capture versions 7.5.x antérieures à 7.5.0 UP6 | ||
| IBM | QRadar SIEM | IBM QRadar SIEM versions 7.5.x antérieures à 7.5.0 UP7 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IBM Sterling Order Management versions 10.0.x ant\u00e9rieures \u00e0 10.0.2309.0",
"product": {
"name": "Sterling",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 on Cloud Pak for Data versions 3.5, 4.0, 4.5, 4.6, 4.7 ant\u00e9rieures \u00e0 4.7 Refresh 3",
"product": {
"name": "N/A",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 versions 10.5.0.x sans les derniers correctifs de s\u00e9curit\u00e9",
"product": {
"name": "Db2",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 versions 11.1.4.x sans les derniers correctifs de s\u00e9curit\u00e9",
"product": {
"name": "Db2",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 REST versions 1.0.0.121-amd64 \u00e0 1.0.0.276-amd64 ant\u00e9rieures \u00e0 1.0.0.291-amd64",
"product": {
"name": "Db2",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 Warehouse on Cloud Pak for Data versions 3.5, 4.0, 4.5, 4.6, 4.7 ant\u00e9rieures \u00e0 4.7 Refresh 3",
"product": {
"name": "N/A",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM Db2 versions 11.5.x sans les derniers correctifs de s\u00e9curit\u00e9",
"product": {
"name": "Db2",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM QRadar Network Packet Capture versions 7.5.x ant\u00e9rieures \u00e0 7.5.0 UP6",
"product": {
"name": "QRadar",
"vendor": {
"name": "IBM",
"scada": false
}
}
},
{
"description": "IBM QRadar SIEM versions 7.5.x ant\u00e9rieures \u00e0 7.5.0 UP7",
"product": {
"name": "QRadar SIEM",
"vendor": {
"name": "IBM",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-21938",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21938"
},
{
"name": "CVE-2019-17267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17267"
},
{
"name": "CVE-2023-21843",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21843"
},
{
"name": "CVE-2022-21426",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21426"
},
{
"name": "CVE-2023-33201",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33201"
},
{
"name": "CVE-2023-32697",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32697"
},
{
"name": "CVE-2023-30991",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30991"
},
{
"name": "CVE-2023-29404",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29404"
},
{
"name": "CVE-2020-9546",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9546"
},
{
"name": "CVE-2023-21954",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21954"
},
{
"name": "CVE-2023-21939",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21939"
},
{
"name": "CVE-2020-13956",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13956"
},
{
"name": "CVE-2023-29256",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29256"
},
{
"name": "CVE-2020-10673",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10673"
},
{
"name": "CVE-2020-35728",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35728"
},
{
"name": "CVE-2020-36181",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36181"
},
{
"name": "CVE-2020-9548",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9548"
},
{
"name": "CVE-2023-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21830"
},
{
"name": "CVE-2020-36182",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36182"
},
{
"name": "CVE-2020-24616",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24616"
},
{
"name": "CVE-2023-30431",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30431"
},
{
"name": "CVE-2022-42703",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42703"
},
{
"name": "CVE-2020-36185",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36185"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2023-32067",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32067"
},
{
"name": "CVE-2022-25147",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25147"
},
{
"name": "CVE-2019-16942",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16942"
},
{
"name": "CVE-2020-9547",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9547"
},
{
"name": "CVE-2020-36179",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36179"
},
{
"name": "CVE-2023-29403",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29403"
},
{
"name": "CVE-2023-35012",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35012"
},
{
"name": "CVE-2023-30443",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30443"
},
{
"name": "CVE-2020-36186",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36186"
},
{
"name": "CVE-2020-36189",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36189"
},
{
"name": "CVE-2020-35490",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35490"
},
{
"name": "CVE-2023-29405",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29405"
},
{
"name": "CVE-2023-34454",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34454"
},
{
"name": "CVE-2023-27869",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27869"
},
{
"name": "CVE-2021-20190",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20190"
},
{
"name": "CVE-2023-26049",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26049"
},
{
"name": "CVE-2023-32342",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32342"
},
{
"name": "CVE-2023-2828",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2828"
},
{
"name": "CVE-2023-30446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30446"
},
{
"name": "CVE-2019-16335",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16335"
},
{
"name": "CVE-2023-34453",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34453"
},
{
"name": "CVE-2023-29007",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29007"
},
{
"name": "CVE-2019-14893",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-14893"
},
{
"name": "CVE-2022-3564",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3564"
},
{
"name": "CVE-2020-11113",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11113"
},
{
"name": "CVE-2023-27868",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27868"
},
{
"name": "CVE-2023-35116",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35116"
},
{
"name": "CVE-2023-20867",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20867"
},
{
"name": "CVE-2023-28709",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28709"
},
{
"name": "CVE-2020-10672",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10672"
},
{
"name": "CVE-2023-0767",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0767"
},
{
"name": "CVE-2020-10969",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10969"
},
{
"name": "CVE-2023-30445",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30445"
},
{
"name": "CVE-2022-40609",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40609"
},
{
"name": "CVE-2020-36187",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36187"
},
{
"name": "CVE-2023-30447",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30447"
},
{
"name": "CVE-2023-30442",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30442"
},
{
"name": "CVE-2023-34455",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34455"
},
{
"name": "CVE-2023-30441",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30441"
},
{
"name": "CVE-2020-11620",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11620"
},
{
"name": "CVE-2023-27867",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27867"
},
{
"name": "CVE-2023-34396",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34396"
},
{
"name": "CVE-2020-24750",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24750"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2023-39976",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39976"
},
{
"name": "CVE-2019-16943",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-16943"
},
{
"name": "CVE-2022-4378",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4378"
},
{
"name": "CVE-2020-28491",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28491"
},
{
"name": "CVE-2019-20330",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20330"
},
{
"name": "CVE-2020-14195",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14195"
},
{
"name": "CVE-2023-21937",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21937"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2020-35491",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35491"
},
{
"name": "CVE-2019-17531",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17531"
},
{
"name": "CVE-2023-33850",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33850"
},
{
"name": "CVE-2023-30448",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30448"
},
{
"name": "CVE-2020-14061",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14061"
},
{
"name": "CVE-2023-2597",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2597"
},
{
"name": "CVE-2020-11619",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11619"
},
{
"name": "CVE-2022-48339",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48339"
},
{
"name": "CVE-2023-27558",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27558"
},
{
"name": "CVE-2020-36183",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36183"
},
{
"name": "CVE-2020-8840",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8840"
},
{
"name": "CVE-2023-38408",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38408"
},
{
"name": "CVE-2023-34981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34981"
},
{
"name": "CVE-2023-30449",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30449"
},
{
"name": "CVE-2020-36184",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36184"
},
{
"name": "CVE-2023-30994",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30994"
},
{
"name": "CVE-2020-36180",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36180"
},
{
"name": "CVE-2023-21968",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21968"
},
{
"name": "CVE-2019-14540",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-14540"
},
{
"name": "CVE-2023-21930",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21930"
},
{
"name": "CVE-2023-25652",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25652"
},
{
"name": "CVE-2023-24998",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24998"
},
{
"name": "CVE-2023-23487",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23487"
},
{
"name": "CVE-2020-10968",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10968"
},
{
"name": "CVE-2020-25649",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25649"
},
{
"name": "CVE-2023-2976",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2976"
},
{
"name": "CVE-2023-40367",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40367"
},
{
"name": "CVE-2023-29402",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29402"
},
{
"name": "CVE-2023-26048",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26048"
},
{
"name": "CVE-2020-11112",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11112"
},
{
"name": "CVE-2023-21967",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21967"
},
{
"name": "CVE-2020-11111",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11111"
},
{
"name": "CVE-2023-34149",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-34149"
},
{
"name": "CVE-2020-14060",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14060"
},
{
"name": "CVE-2020-36188",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-36188"
},
{
"name": "CVE-2016-1000027",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1000027"
},
{
"name": "CVE-2019-14892",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-14892"
},
{
"name": "CVE-2020-14062",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14062"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0839",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-10-13T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
},
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits IBM\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire\n\u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et une\n\u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits IBM",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7047565 du 06 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7047565"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7049129 du 10 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7049129"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7047481 du 06 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7047481"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7049434 du 10 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7049434"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7047499 du 06 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7047499"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7047754 du 06 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7047754"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7049133 du 10 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7049133"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7047724 du 06 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7047724"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 IBM 7049435 du 10 octobre 2023",
"url": "https://www.ibm.com/support/pages/node/7049435"
}
]
}
CERTFR-2024-AVI-0027
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Juniper Networks. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Juniper Networks | N/A | CTPView versions versions antérieures à 9.1R5 | ||
| Juniper Networks | Junos OS Evolved | Junos OS Evolved version antérieures à 20.4R2-EVO, 20.4R2-S2-EVO, 20.4R3-EVO, 20.4R3-S7-EVO, 21.1R2-EVO, 21.2R2-EVO, 21.2R3-S7-EVO, 21.3R2-EVO, 21.3R3-S5-EVO, 21.4R3-EVO, 21.4R3-S3-EVO, 21.4R3-S5-EVO, 21.4R3-S6-EVO, 22.1R3-EVO, 22.1R3-S2-EVO, 22.1R3-S4-EVO, 22.1R3-S5-EVO, 22.2R2-S1-EVO, 22.2R2-S2-EVO, 22.2R3-EVO, 22.2R3-S2-EVO, 22.2R3-S3-EVO, 22.3R1-EVO, 22.3R2-EVO, 22.3R3-EVO, 22.3R3-S1-EVO, 22.4R1-EVO, 22.4R2-EVO, 22.4R2-S2-EVO, 22.4R3-EVO, 23.1R2-EVO, 23.2R1-EVO, 23.2R1-S1-EVO, 23.2R1-S2-EVO, 23.2R2-EVO, 23.3R1-EVO et 23.4R1-EVO | ||
| Juniper Networks | N/A | Paragon Active Assurance versions antérieures à 3.1.2, 3.2.3, 3.3.2 et 3.4.1 | ||
| Juniper Networks | Junos OS | Junos OS version antérieures à 20.4R3-S3, 20.4R3-S6, 20.4R3-S7, 20.4R3-S8, 20.4R3-S9, 21.1R3-S4, 21.1R3-S5, 21.2R3, 21.2R3-S3, 21.2R3-S4, 21.2R3-S5, 21.2R3-S6, 21.2R3-S7, 21.3R2-S1, 21.3R3, 21.3R3-S3, 21.3R3-S4, 21.3R3-S5, 21.4R2, 21.4R3, 21.4R3-S3, 21.4R3-S4, 21.4R3-S5, 22.1R2, 22.1R2-S2, 22.1R3, 22.1R3-S1, 22.1R3-S2, 22.1R3-S3, 22.1R3-S4, 22.2R1, 22.2R2, 22.2R2-S1, 22.2R2-S2, 22.2R3, 22.2R3-S1, 22.2R3-S2, 22.2R3-S3, 22.3R1, 22.3R2, 22.3R2-S1, 22.3R2-S2, 22.3R3, 22.3R3-S1, 22.3R3-S2, 22.4R1, 22.4R1-S2, 22.4R2, 22.4R2-S1, 22.4R2-S2, 22.4R3, 23.1R1, 23.1R2, 23.2R1, 23.2R1-S1, 23.2R1-S2, 23.2R2, 23.3R1 et 23.4R1 | ||
| Juniper Networks | Session Smart Router | Session Smart Router versions antérieures à SSR-6.2.3-r2 | ||
| Juniper Networks | N/A | Security Director Insights versions antérieures à 23.1R1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "CTPView versions versions ant\u00e9rieures \u00e0 9.1R5",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS Evolved version ant\u00e9rieures \u00e0 20.4R2-EVO, 20.4R2-S2-EVO, 20.4R3-EVO, 20.4R3-S7-EVO, 21.1R2-EVO, 21.2R2-EVO, 21.2R3-S7-EVO, 21.3R2-EVO, 21.3R3-S5-EVO, 21.4R3-EVO, 21.4R3-S3-EVO, 21.4R3-S5-EVO, 21.4R3-S6-EVO, 22.1R3-EVO, 22.1R3-S2-EVO, 22.1R3-S4-EVO, 22.1R3-S5-EVO, 22.2R2-S1-EVO, 22.2R2-S2-EVO, 22.2R3-EVO, 22.2R3-S2-EVO, 22.2R3-S3-EVO, 22.3R1-EVO, 22.3R2-EVO, 22.3R3-EVO, 22.3R3-S1-EVO, 22.4R1-EVO, 22.4R2-EVO, 22.4R2-S2-EVO, 22.4R3-EVO, 23.1R2-EVO, 23.2R1-EVO, 23.2R1-S1-EVO, 23.2R1-S2-EVO, 23.2R2-EVO, 23.3R1-EVO et 23.4R1-EVO",
"product": {
"name": "Junos OS Evolved",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Paragon Active Assurance versions ant\u00e9rieures \u00e0 3.1.2, 3.2.3, 3.3.2 et 3.4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Junos OS version ant\u00e9rieures \u00e0 20.4R3-S3, 20.4R3-S6, 20.4R3-S7, 20.4R3-S8, 20.4R3-S9, 21.1R3-S4, 21.1R3-S5, 21.2R3, 21.2R3-S3, 21.2R3-S4, 21.2R3-S5, 21.2R3-S6, 21.2R3-S7, 21.3R2-S1, 21.3R3, 21.3R3-S3, 21.3R3-S4, 21.3R3-S5, 21.4R2, 21.4R3, 21.4R3-S3, 21.4R3-S4, 21.4R3-S5, 22.1R2, 22.1R2-S2, 22.1R3, 22.1R3-S1, 22.1R3-S2, 22.1R3-S3, 22.1R3-S4, 22.2R1, 22.2R2, 22.2R2-S1, 22.2R2-S2, 22.2R3, 22.2R3-S1, 22.2R3-S2, 22.2R3-S3, 22.3R1, 22.3R2, 22.3R2-S1, 22.3R2-S2, 22.3R3, 22.3R3-S1, 22.3R3-S2, 22.4R1, 22.4R1-S2, 22.4R2, 22.4R2-S1, 22.4R2-S2, 22.4R3, 23.1R1, 23.1R2, 23.2R1, 23.2R1-S1, 23.2R1-S2, 23.2R2, 23.3R1 et 23.4R1",
"product": {
"name": "Junos OS",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Session Smart Router versions ant\u00e9rieures \u00e0 SSR-6.2.3-r2",
"product": {
"name": "Session Smart Router",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
},
{
"description": "Security Director Insights versions ant\u00e9rieures \u00e0 23.1R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Juniper Networks",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-3707",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3707"
},
{
"name": "CVE-2024-21602",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21602"
},
{
"name": "CVE-2022-41974",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41974"
},
{
"name": "CVE-2023-38802",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38802"
},
{
"name": "CVE-2023-21938",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21938"
},
{
"name": "CVE-2023-21843",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21843"
},
{
"name": "CVE-2022-42720",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42720"
},
{
"name": "CVE-2022-30594",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30594"
},
{
"name": "CVE-2022-41973",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41973"
},
{
"name": "CVE-2023-0461",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0461"
},
{
"name": "CVE-2024-21616",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21616"
},
{
"name": "CVE-2021-25220",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25220"
},
{
"name": "CVE-2023-2235",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2235"
},
{
"name": "CVE-2023-23454",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23454"
},
{
"name": "CVE-2023-21954",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21954"
},
{
"name": "CVE-2022-2964",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2964"
},
{
"name": "CVE-2023-21939",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21939"
},
{
"name": "CVE-2023-1281",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1281"
},
{
"name": "CVE-2024-21599",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21599"
},
{
"name": "CVE-2022-47929",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47929"
},
{
"name": "CVE-2022-3628",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3628"
},
{
"name": "CVE-2024-21614",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21614"
},
{
"name": "CVE-2023-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21830"
},
{
"name": "CVE-2023-3817",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3817"
},
{
"name": "CVE-2023-26464",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26464"
},
{
"name": "CVE-2020-0466",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-0466"
},
{
"name": "CVE-2021-26691",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26691"
},
{
"name": "CVE-2022-4269",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4269"
},
{
"name": "CVE-2022-42703",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42703"
},
{
"name": "CVE-2024-21607",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21607"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2023-32067",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32067"
},
{
"name": "CVE-2023-0266",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0266"
},
{
"name": "CVE-2019-17571",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-17571"
},
{
"name": "CVE-2022-39189",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39189"
},
{
"name": "CVE-2022-3239",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3239"
},
{
"name": "CVE-2022-43750",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43750"
},
{
"name": "CVE-2022-3567",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3567"
},
{
"name": "CVE-2023-2828",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2828"
},
{
"name": "CVE-2021-4104",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4104"
},
{
"name": "CVE-2023-22081",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22081"
},
{
"name": "CVE-2023-20569",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20569"
},
{
"name": "CVE-2024-21596",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21596"
},
{
"name": "CVE-2022-3564",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3564"
},
{
"name": "CVE-2021-33656",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33656"
},
{
"name": "CVE-2023-1582",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1582"
},
{
"name": "CVE-2022-4129",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4129"
},
{
"name": "CVE-2022-41218",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41218"
},
{
"name": "CVE-2023-2194",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2194"
},
{
"name": "CVE-2024-21604",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21604"
},
{
"name": "CVE-2023-32360",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32360"
},
{
"name": "CVE-2022-0934",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0934"
},
{
"name": "CVE-2020-9493",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9493"
},
{
"name": "CVE-2021-3573",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3573"
},
{
"name": "CVE-2022-2196",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2196"
},
{
"name": "CVE-2021-39275",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39275"
},
{
"name": "CVE-2022-42896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42896"
},
{
"name": "CVE-2022-21699",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21699"
},
{
"name": "CVE-2024-21600",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21600"
},
{
"name": "CVE-2021-33655",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33655"
},
{
"name": "CVE-2023-0767",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0767"
},
{
"name": "CVE-2022-1462",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1462"
},
{
"name": "CVE-2023-23920",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23920"
},
{
"name": "CVE-2023-20593",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-20593"
},
{
"name": "CVE-2024-21606",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21606"
},
{
"name": "CVE-2022-0330",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0330"
},
{
"name": "CVE-2022-41222",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41222"
},
{
"name": "CVE-2016-10009",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-10009"
},
{
"name": "CVE-2022-23305",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23305"
},
{
"name": "CVE-2022-2663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2663"
},
{
"name": "CVE-2023-23918",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23918"
},
{
"name": "CVE-2024-21591",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21591"
},
{
"name": "CVE-2020-12321",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12321"
},
{
"name": "CVE-2022-23307",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23307"
},
{
"name": "CVE-2022-3524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3524"
},
{
"name": "CVE-2022-39188",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39188"
},
{
"name": "CVE-2023-3341",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3341"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2022-2795",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2795"
},
{
"name": "CVE-2022-22942",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22942"
},
{
"name": "CVE-2022-43945",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43945"
},
{
"name": "CVE-2022-3625",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3625"
},
{
"name": "CVE-2021-34798",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34798"
},
{
"name": "CVE-2024-21587",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21587"
},
{
"name": "CVE-2022-42721",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42721"
},
{
"name": "CVE-2022-4378",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4378"
},
{
"name": "CVE-2022-4254",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4254"
},
{
"name": "CVE-2024-21617",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21617"
},
{
"name": "CVE-2023-1195",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1195"
},
{
"name": "CVE-2024-21589",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21589"
},
{
"name": "CVE-2023-21937",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21937"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2022-20141",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-20141"
},
{
"name": "CVE-2021-4155",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4155"
},
{
"name": "CVE-2023-2650",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2650"
},
{
"name": "CVE-2024-21595",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21595"
},
{
"name": "CVE-2021-3564",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3564"
},
{
"name": "CVE-2021-3621",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3621"
},
{
"name": "CVE-2023-0394",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0394"
},
{
"name": "CVE-2022-22164",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22164"
},
{
"name": "CVE-2024-21597",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21597"
},
{
"name": "CVE-2021-3752",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3752"
},
{
"name": "CVE-2023-0386",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0386"
},
{
"name": "CVE-2016-2183",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-2183"
},
{
"name": "CVE-2021-26341",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-26341"
},
{
"name": "CVE-2022-38023",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-38023"
},
{
"name": "CVE-2023-22045",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22045"
},
{
"name": "CVE-2022-1679",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1679"
},
{
"name": "CVE-2023-22049",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22049"
},
{
"name": "CVE-2023-38408",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38408"
},
{
"name": "CVE-2022-3619",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3619"
},
{
"name": "CVE-2021-0920",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-0920"
},
{
"name": "CVE-2023-1829",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1829"
},
{
"name": "CVE-2022-25265",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25265"
},
{
"name": "CVE-2022-1789",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1789"
},
{
"name": "CVE-2022-2873",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2873"
},
{
"name": "CVE-2022-3623",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3623"
},
{
"name": "CVE-2024-21611",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21611"
},
{
"name": "CVE-2024-21613",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21613"
},
{
"name": "CVE-2021-44228",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
},
{
"name": "CVE-2023-21968",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21968"
},
{
"name": "CVE-2024-21612",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21612"
},
{
"name": "CVE-2022-42722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42722"
},
{
"name": "CVE-2024-21603",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21603"
},
{
"name": "CVE-2023-21930",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21930"
},
{
"name": "CVE-2024-21585",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21585"
},
{
"name": "CVE-2022-23302",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23302"
},
{
"name": "CVE-2023-24329",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24329"
},
{
"name": "CVE-2021-44832",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44832"
},
{
"name": "CVE-2021-44790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44790"
},
{
"name": "CVE-2023-36842",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36842"
},
{
"name": "CVE-2022-4139",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4139"
},
{
"name": "CVE-2024-21594",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21594"
},
{
"name": "CVE-2022-3028",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3028"
},
{
"name": "CVE-2022-3566",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3566"
},
{
"name": "CVE-2023-3446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3446"
},
{
"name": "CVE-2023-21967",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21967"
},
{
"name": "CVE-2022-41674",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41674"
},
{
"name": "CVE-2024-21601",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21601"
},
{
"name": "CVE-2023-2124",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2124"
},
{
"name": "CVE-2020-0465",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-0465"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0027",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-01-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nJuniper Networks. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Juniper Networks",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75723 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-rpd-process-crash-due-to-BGP-flap-on-NSR-enabled-devices-CVE-2024-21585"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75741 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-PTX-Series-In-an-FTI-scenario-MPLS-packets-hitting-reject-next-hop-will-cause-a-host-path-wedge-condition-CVE-2024-21600"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75752 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-In-a-jflow-scenario-continuous-route-churn-will-cause-a-memory-leak-and-eventually-an-rpd-crash-CVE-2024-21611"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75757 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Processing-of-a-specific-SIP-packet-causes-NAT-IP-allocation-to-fail-CVE-2024-21616"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75730 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-jdhcpd-will-hang-on-receiving-a-specific-DHCP-packet-CVE-2023-36842"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75734 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-EX4100-EX4400-EX4600-and-QFX5000-Series-A-high-rate-of-specific-ICMP-traffic-will-cause-the-PFE-to-hang-CVE-2024-21595"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75737 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Security-Director-Insights-Multiple-vulnerabilities-in-SDI"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75721 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Evolved-IPython-privilege-escalation-vulnerability-CVE-2022-21699"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75736 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-CTPView-Multiple-vulnerabilities-in-CTPView-CVE-yyyy-nnnn"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75747 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-SRX-Series-flowd-will-crash-when-tcp-encap-is-enabled-and-specific-packets-are-received-CVE-2024-21606"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75758 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-BGP-flap-on-NSR-enabled-devices-causes-memory-leak-CVE-2024-21617"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA11272 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2022-01-Security-Bulletin-Junos-OS-Evolved-Telnet-service-may-be-enabled-when-it-is-expected-to-be-disabled-CVE-2022-22164"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75727 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Paragon-Active-Assurance-Control-Center-Information-disclosure-vulnerability-CVE-2024-21589"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75233 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Session-Smart-Router-Multiple-vulnerabilities-resolved"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75754 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-A-link-flap-causes-patroot-memory-leak-which-leads-to-rpd-crash-CVE-2024-21613"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75753 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Evolved-Specific-TCP-traffic-causes-OFP-core-and-restart-of-RE-CVE-2024-21612"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75742 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-SRX-Series-Due-to-an-error-in-processing-TCP-events-flowd-will-crash-CVE-2024-21601"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75740 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-MX-Series-MPC3E-memory-leak-with-PTP-configuration-CVE-2024-21599"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75748 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-MX-Series-and-EX9200-Series-If-the-tcp-reset-option-used-in-an-IPv6-filter-matched-packets-are-accepted-instead-of-rejected-CVE-2024-21607"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75744 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-MX-Series-Gathering-statistics-in-a-scaled-SCU-DCU-configuration-will-lead-to-a-device-crash-CVE-2024-21603"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75743 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Evolved-ACX7024-ACX7100-32C-and-ACX7100-48L-Traffic-stops-when-a-specific-IPv4-UDP-packet-is-received-by-the-RE-CVE-2024-21602"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75738 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-MX-Series-In-an-AF-scenario-traffic-can-bypass-configured-lo0-firewall-filters-CVE-2024-21597"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75733 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-SRX-5000-Series-Repeated-execution-of-a-specific-CLI-command-causes-a-flowd-crash-CVE-2024-21594"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75725 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Memory-leak-in-bbe-smgd-process-if-BFD-liveness-detection-for-DHCP-subscribers-is-enabled-CVE-2024-21587"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75755 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-A-specific-query-via-DREND-causes-rpd-crash-CVE-2024-21614"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75735 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-and-Junos-OS-Evolved-A-specific-BGP-UPDATE-message-will-cause-a-crash-in-the-backup-Routing-Engine-CVE-2024-21596"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75745 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-Evolved-A-high-rate-of-specific-traffic-will-cause-a-complete-system-outage-CVE-2024-21604"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Juniper JSA75729 du 10 janvier 2024",
"url": "https://supportportal.juniper.net/s/article/2024-01-Security-Bulletin-Junos-OS-SRX-Series-and-EX-Series-Security-Vulnerability-in-J-web-allows-a-preAuth-Remote-Code-Execution-CVE-2024-21591"
}
]
}
alsa-2023:0282
Vulnerability from osv_almalinux
The sudo packages contain the sudo utility which allows system administrators to provide certain users with the permission to execute privileged commands, which are used for system management purposes, without having to log in as root.
Security Fix(es):
- sudo: arbitrary file write with privileges of the RunAs user (CVE-2023-22809)
For more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.
{
"affected": [
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "sudo"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1.9.5p2-7.el9_1.1"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "sudo-python-plugin"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1.9.5p2-7.el9_1.1"
}
],
"type": "ECOSYSTEM"
}
]
}
],
"details": "The sudo packages contain the sudo utility which allows system administrators to provide certain users with the permission to execute privileged commands, which are used for system management purposes, without having to log in as root.\n\nSecurity Fix(es):\n\n* sudo: arbitrary file write with privileges of the RunAs user (CVE-2023-22809)\n\nFor more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.",
"id": "ALSA-2023:0282",
"modified": "2023-01-24T07:20:47Z",
"published": "2023-01-23T00:00:00Z",
"references": [
{
"type": "ADVISORY",
"url": "https://access.redhat.com/errata/RHSA-2023:0282"
},
{
"type": "REPORT",
"url": "https://access.redhat.com/security/cve/CVE-2023-22809"
},
{
"type": "REPORT",
"url": "https://bugzilla.redhat.com/2161142"
},
{
"type": "ADVISORY",
"url": "https://errata.almalinux.org/9/ALSA-2023-0282.html"
}
],
"related": [
"CVE-2023-22809"
],
"summary": "Important: sudo security update"
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.