CVE-2023-29131
Vulnerability from cvelistv5
Published
2023-07-11 09:07
Modified
2024-08-02 14:00
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.
Impacted products
SiemensSIMATIC CN 4100
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.794Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CN 4100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-11T09:07:07.238Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29131",
    "datePublished": "2023-07-11T09:07:07.238Z",
    "dateReserved": "2023-03-31T10:54:26.824Z",
    "dateUpdated": "2024-08-02T14:00:15.794Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29131\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-07-11T10:15:10.473\",\"lastModified\":\"2023-07-18T16:30:33.707\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.1,\"impactScore\":3.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.5\",\"matchCriteriaId\":\"3F50C1C5-0934-44E6-A3F3-C473B6EA82F4\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-313488.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.