CVE-2023-2914
Vulnerability from cvelistv5
Published
2023-08-17 15:01
Modified
2024-10-08 17:08
Severity ?
EPSS score ?
Summary
Rockwell Automation ThinManager Thinserver Software Vulnerable to Input Validation Vulnerabilitiy
References
▼ | URL | Tags | |
---|---|---|---|
PSIRT@rockwellautomation.com | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471 | Permissions Required |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Rockwell Automation | ThinManager ThinServer |
Version: 11.0.0 - 11.2.6 Version: 11.1.0 - 11.1.6 Version: 11.2.0 - 11.2.7 Version: 12.0.0 - 12.0.5 Version: 12.1.0 - 12.1.6 Version: 13.0.0 - 13.0.2 Version: 13.1.0 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T06:41:03.723Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "thinmanager_thinserver", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "11.0.0 - 11.2.6" }, { "status": "affected", "version": "11.1.0 - 11.1.6" }, { "status": "affected", "version": "11.2.0 - 11.2.7" }, { "status": "affected", "version": "12.0.0 - 12.0.5" }, { "status": "affected", "version": "12.1.0 - 12.1.6" }, { "status": "affected", "version": "13.0.0 - 13.0.2" }, { "status": "affected", "version": "13.1.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-2914", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T17:05:51.847648Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T17:08:30.894Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThinManager ThinServer", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "11.0.0 - 11.2.6" }, { "status": "affected", "version": "11.1.0 - 11.1.6" }, { "status": "affected", "version": "11.2.0 - 11.2.7" }, { "status": "affected", "version": "12.0.0 - 12.0.5" }, { "status": "affected", "version": "12.1.0 - 12.1.6" }, { "status": "affected", "version": "13.0.0 - 13.0.2" }, { "status": "affected", "version": "13.1.0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "This vulnerability was reported to Rockwell Automation by Tenable Network Security." } ], "datePublic": "2023-08-17T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software. " } ], "value": "The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software. " } ], "impacts": [ { "capecId": "CAPEC-126", "descriptions": [ { "lang": "en", "value": "CAPEC-126 Path Traversal" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-17T15:03:27.110Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to the corrected software versions.\u003c/li\u003e\u003cli\u003eLimit remote access for TCP Port 2031 to known thin clients and ThinManager servers.\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\n * Update to the corrected software versions.\n * Limit remote access for TCP Port 2031 to known thin clients and ThinManager servers.\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Rockwell Automation ThinManager Thinserver Software Vulnerable to Input Validation Vulnerabilitiy", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2023-2914", "datePublished": "2023-08-17T15:01:25.994Z", "dateReserved": "2023-05-26T13:23:41.377Z", "dateUpdated": "2024-10-08T17:08:30.894Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-2914\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2023-08-17T16:15:09.513\",\"lastModified\":\"2023-08-23T15:46:19.610\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software. \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-190\"}]},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.0.0\",\"versionEndIncluding\":\"11.0.6\",\"matchCriteriaId\":\"6C40EF89-902D-40A0-9460-9C2037CDAF45\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.1.0\",\"versionEndIncluding\":\"11.1.6\",\"matchCriteriaId\":\"DCB9F021-2307-4183-A6B8-CAEE88808C92\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.2.0\",\"versionEndIncluding\":\"11.2.7\",\"matchCriteriaId\":\"A8C2E2BF-3ABA-4E69-9A8F-4E2AC6C48E2E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.0\",\"versionEndIncluding\":\"12.0.5\",\"matchCriteriaId\":\"66054D47-416A-4194-9B95-AE810924AD94\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.1.0\",\"versionEndIncluding\":\"12.1.6\",\"matchCriteriaId\":\"3AAE89B3-6C25-4DE7-898A-2F8637122B01\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.0.0\",\"versionEndIncluding\":\"13.0.2\",\"matchCriteriaId\":\"A5D9F5DA-D66A-4F88-A1C4-E1411715162F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:13.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE7FC8D4-F5EF-45DC-9D95-4CFBC3FE1E3B\"}]}]}],\"references\":[{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Permissions Required\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.