CVE-2023-30795
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 22:16
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf | Patch, Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:37:15.439Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-30795", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-11T22:16:06.900938Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-11T22:16:31.109Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT Open", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.4" } ] }, { "defaultStatus": "unknown", "product": "JT Utilities", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.4" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.0.253" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.243" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.177" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.1.073" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4), Parasolid V34.0 (All versions \u003c V34.0.253), Parasolid V34.1 (All versions \u003c V34.1.243), Parasolid V35.0 (All versions \u003c V35.0.177), Parasolid V35.1 (All versions \u003c V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-08T09:20:19.964Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30795", "datePublished": "2023-08-08T09:20:19.964Z", "dateReserved": "2023-04-18T09:19:57.943Z", "dateUpdated": "2024-10-11T22:16:31.109Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-30795\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-08-08T10:15:15.067\",\"lastModified\":\"2023-08-11T14:22:05.067\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4), Parasolid V34.0 (All versions \u003c V34.0.253), Parasolid V34.1 (All versions \u003c V34.1.243), Parasolid V35.0 (All versions \u003c V35.0.177), Parasolid V35.1 (All versions \u003c V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT Open (Todas las versiones inferiores a V11.4), JT Utilities (Todas las versiones inferiores a V13.4), Parasolid V34.0 (Todas las versiones inferiores a V34.0.253), Parasolid V34.1 (Todas las versiones inferiores a V34.1.243), Parasolid V35.0 (Todas las versiones inferiores a V35.0.177), Parasolid V35.1 (Todas las versiones inferiores a V35.1.073). Las aplicaciones afectadas contienen una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada al analizar archivos JT especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.4\",\"matchCriteriaId\":\"0C5E38E9-C07C-4E2C-A2A5-B3A0E77B5B00\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.4\",\"matchCriteriaId\":\"C1B0B2A2-1A1A-4B0F-B957-2D5B6EBDB0FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.0\",\"versionEndExcluding\":\"34.0.253\",\"matchCriteriaId\":\"0856DA04-7E50-4EF7-AB5A-D09349B188B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.243\",\"matchCriteriaId\":\"2785D65C-6EA7-4602-9A81-6E54F45E9F43\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.177\",\"matchCriteriaId\":\"884A8645-3BB6-4AF6-9B3A-1C73E9F8344B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.073\",\"matchCriteriaId\":\"C3FD284B-0089-4430-89F0-41B93D61C717\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.