Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Dell | PowerSwitch Z9664F-ON BIOS |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:dell:powerswitch_z9664f_on-bios:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerswitch_z9664f_on-bios", "vendor": "dell", "versions": [ { "lessThan": "v1.05.10", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-32472", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T18:34:02.518285Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-23T18:43:41.144Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T15:18:37.025Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerSwitch Z9664F-ON BIOS", "vendor": "Dell", "versions": [ { "lessThan": "v1.05.10", "status": "affected", "version": "N/A", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues" } ], "datePublic": "2023-06-14T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege." } ], "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-26T11:57:38.816Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2023-32472", "datePublished": "2024-07-10T02:32:00.277Z", "dateReserved": "2023-05-09T06:07:41.364Z", "dateUpdated": "2024-09-26T11:57:38.816Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-32472\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-07-10T03:15:02.193\",\"lastModified\":\"2024-09-26T12:15:02.800\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege.\"},{\"lang\":\"es\",\"value\":\"El BIOS de Dell Edge Gateway, versiones 3200 y 5200, contiene una vulnerabilidad de escritura fuera de los l\u00edmites. Un usuario malintencionado local autenticado con altos privilegios podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la exposici\u00f3n de parte del c\u00f3digo en el modo de administraci\u00f3n del sistema, lo que provocar\u00eda la ejecuci\u00f3n de c\u00f3digo arbitrario o una escalada de privilegios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.5,\"impactScore\":6.0},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.5,\"impactScore\":3.7}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:edge_gateway_3200_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"44A5114F-DF4F-4E59-9644-079B266D3C7E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:edge_gateway_3200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBA59414-5A32-4706-85A5-D5459EE22BA5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.05.10\",\"matchCriteriaId\":\"A390E554-5359-4D9F-B5FA-A62CFE7471E0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:edge_gateway_5200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6832A53-E950-4572-A178-CF5DC14CACC5\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.