CVE-2023-37376
Vulnerability from cvelistv5
Published
2023-07-11 09:07
Modified
2024-08-02 17:09
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:09:34.172Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0008"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0002"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:32:12.593Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-37376",
    "datePublished": "2023-07-11T09:07:28.531Z",
    "dateReserved": "2023-07-03T13:24:27.346Z",
    "dateUpdated": "2024-08-02T17:09:34.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-37376\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-07-11T10:15:11.877\",\"lastModified\":\"2023-07-18T14:56:17.227\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2201\",\"versionEndExcluding\":\"2201.0008\",\"matchCriteriaId\":\"0E8C9093-BD78-4ECE-9221-A889371B3839\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2302\",\"versionEndExcluding\":\"2302.0002\",\"matchCriteriaId\":\"C7103507-EE73-42FF-9DAB-37DD06467591\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}