CVE-2023-38680
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 13:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Tecnomatix Plant Simulation V2201 |
Version: All versions < V2201.0008 |
||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-02T17:46:56.555Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf", }, ], title: "CVE Program Container", }, { metrics: [ { other: { content: { id: "CVE-2023-38680", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "total", }, ], role: "CISA Coordinator", timestamp: "2024-10-11T13:18:33.968086Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-10-11T13:18:43.701Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Tecnomatix Plant Simulation V2201", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2201.0008", }, ], }, { defaultStatus: "unknown", product: "Tecnomatix Plant Simulation V2302", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2302.0002", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)", }, ], metrics: [ { cvssV3_1: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-787", description: "CWE-787: Out-of-bounds Write", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2023-09-12T09:32:22.373Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2023-38680", datePublished: "2023-08-08T09:20:45.202Z", dateReserved: "2023-07-24T09:52:57.445Z", dateUpdated: "2024-10-11T13:18:43.701Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2201\", \"versionEndExcluding\": \"2201.0008\", \"matchCriteriaId\": \"0E8C9093-BD78-4ECE-9221-A889371B3839\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2302\", \"versionEndExcluding\": \"2302.0002\", \"matchCriteriaId\": \"C7103507-EE73-42FF-9DAB-37DD06467591\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones inferiores a V2201.0008), Tecnomatix Plant Simulation V2302 (Todas las versiones inferiores a V2302.0002). La aplicaci\\u00f3n afectada contiene una escritura fuera de l\\u00edmites m\\u00e1s all\\u00e1 del final de un b\\u00fafer asignado mientras analiza un archivo SPP especialmente dise\\u00f1ado. Esto podr\\u00eda permitir a un atacante ejecutar c\\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21132)\"}]", id: "CVE-2023-38680", lastModified: "2024-11-21T08:14:02.270", metrics: "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}", published: "2023-08-08T10:15:16.677", references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2023-38680\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-08-08T10:15:16.677\",\"lastModified\":\"2024-11-21T08:14:02.270\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones inferiores a V2201.0008), Tecnomatix Plant Simulation V2302 (Todas las versiones inferiores a V2302.0002). La aplicación afectada contiene una escritura fuera de límites más allá del final de un búfer asignado mientras analiza un archivo SPP especialmente diseñado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-21132)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2201\",\"versionEndExcluding\":\"2201.0008\",\"matchCriteriaId\":\"0E8C9093-BD78-4ECE-9221-A889371B3839\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2302\",\"versionEndExcluding\":\"2302.0002\",\"matchCriteriaId\":\"C7103507-EE73-42FF-9DAB-37DD06467591\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", vulnrichment: { containers: "{\"cna\": {\"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-09-12T09:32:22.373Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)\"}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2201\", \"versions\": [{\"version\": \"All versions < V2201.0008\", \"status\": \"affected\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2302\", \"versions\": [{\"version\": \"All versions < V2302.0002\", \"status\": \"affected\"}], \"defaultStatus\": \"unknown\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\"}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787: Out-of-bounds Write\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\"}]}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T17:46:56.555Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"tags\": [\"x_transferred\"]}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-38680\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-11T13:18:33.968086Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-11T13:18:38.989Z\"}}]}", cveMetadata: "{\"cveId\": \"CVE-2023-38680\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"siemens\", \"dateReserved\": \"2023-07-24T09:52:57.445Z\", \"datePublished\": \"2023-08-08T09:20:45.202Z\", \"dateUpdated\": \"2024-10-11T13:18:43.701Z\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.