CVE-2023-43503
Vulnerability from cvelistv5
Published
2023-11-14 11:03
Modified
2024-08-02 19:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in COMOS (All versions < V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:44:42.702Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "COMOS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V10.4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in COMOS (All versions \u003c V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP." } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:03:45.149Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-43503", "datePublished": "2023-11-14T11:03:45.149Z", "dateReserved": "2023-09-19T10:00:12.440Z", "dateUpdated": "2024-08-02T19:44:42.702Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-43503\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-11-14T11:15:11.297\",\"lastModified\":\"2023-11-17T23:54:12.197\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in COMOS (All versions \u003c V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en COMOS (Todas las versiones \u0026lt; V10.4.4). El sistema de almacenamiento en cach\u00e9 de la aplicaci\u00f3n afectada filtra informaci\u00f3n confidencial, como informaci\u00f3n del usuario y del proyecto, en texto plano a trav\u00e9s de UDP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.5,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":2.1,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.4.4\",\"matchCriteriaId\":\"F0C7BA84-5F46-4F5C-B856-F9DA231DAC1A\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-137900.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.