Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.
Impacted products
SiemensSIMATIC PCS neo
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:39.332Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:04:19.007Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-46097",
    "datePublished": "2023-11-14T11:04:19.007Z",
    "dateReserved": "2023-10-16T11:24:12.686Z",
    "dateUpdated": "2024-08-02T20:37:39.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-46097\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-11-14T11:15:14.360\",\"lastModified\":\"2023-11-20T14:38:29.960\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones \u0026lt; V4.1). El PUD Manager de los productos afectados no neutraliza adecuadamente las entradas proporcionadas por el usuario. Esto podr\u00eda permitir que un atacante adyacente autenticado ejecute declaraciones SQL en la base de datos subyacente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.0,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.1,\"impactScore\":4.2}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"96D49ACA-BF2E-4C89-8168-E4A95D5B22AA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.