CVE-2023-5986
Vulnerability from cvelistv5
Published
2023-11-15 03:47
Modified
2024-08-02 08:14
Severity ?
EPSS score ?
Summary
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input
attackers can cause the software’s web application to redirect to the chosen domain after a
successful login is performed.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:25.141Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2020 CU2 and prior" }, { "status": "affected", "version": "Version 2021 CU1 and prior" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021" }, { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n" } ], "value": "\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-601", "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-15T03:47:17.684Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5986", "datePublished": "2023-11-15T03:47:17.684Z", "dateReserved": "2023-11-07T10:57:54.715Z", "dateUpdated": "2024-08-02T08:14:25.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-5986\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-11-15T04:15:19.487\",\"lastModified\":\"2023-11-30T15:24:25.580\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\\nsuccessful login is performed. \\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-601: Redireccionamiento de URL a un Sitio que No es de Confianza que podr\u00eda causar una vulnerabilidad de openredirect que conduzca a un ataque de cross site scripting. Al proporcionar una entrada codificada en URL, los atacantes pueden hacer que la aplicaci\u00f3n web del software se redirija al dominio elegido despu\u00e9s de iniciar sesi\u00f3n correctamente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":4.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4A6EB67-7D2A-4899-BAC7-18BD6F5D6700\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"62689EF4-C9D4-47FB-9722-C9C2EFB0C858\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D20050D-A7BB-4BB1-9C4C-DB3321DF087B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4579BF1-DD9F-4AD7-A1CE-2AD2B7389B8D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:cumulative_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B38506D4-26CD-405C-99FC-0E8F9D39DA57\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.