CVE-2023-5987
Vulnerability from cvelistv5
Published
2023-11-15 03:48
Modified
2024-08-02 08:14
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:25.122Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Monitoring Expert (PME)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2020 CU2 and prior"
            },
            {
              "status": "affected",
              "version": "Version 2021 CU1 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
            },
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
            }
          ],
          "value": "\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T03:48:50.993Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-5987",
    "datePublished": "2023-11-15T03:48:50.993Z",
    "dateReserved": "2023-11-07T10:58:51.030Z",
    "dateUpdated": "2024-08-02T08:14:25.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-5987\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-11-15T04:15:19.700\",\"lastModified\":\"2023-11-30T15:05:45.607\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\\nthe injected payload.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad CWE-79: Neutralizaci\u00f3n Inadecuada de la Entrada Durante la Generaci\u00f3n de P\u00e1ginas Web (Cross-site Scripting) que podr\u00eda causar una vulnerabilidad que conduzca a una condici\u00f3n de Cross-Site Scripting donde los atacantes pueden hacer que el navegador de la v\u00edctima ejecute JavaScript arbitrario cuando visitan una p\u00e1gina que contiene un payload inyectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4A6EB67-7D2A-4899-BAC7-18BD6F5D6700\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"62689EF4-C9D4-47FB-9722-C9C2EFB0C858\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D20050D-A7BB-4BB1-9C4C-DB3321DF087B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4579BF1-DD9F-4AD7-A1CE-2AD2B7389B8D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:cumulative_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B38506D4-26CD-405C-99FC-0E8F9D39DA57\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.