CVE-2024-38296
Vulnerability from cvelistv5
Published
2024-11-22 02:58
Modified
2024-12-09 15:03
Summary
Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "edge_gateway_5200_firmware",
            "vendor": "dell",
            "versions": [
              {
                "lessThan": "12.0.94.2380",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-38296",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T18:18:21.316783Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T18:20:39.113Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Edge Gateway 5200",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "12.0.94.2380",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank the Eclypsium Research Team for reporting this issue"
        }
      ],
      "datePublic": "2024-11-21T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
            }
          ],
          "value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1421",
              "description": "CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-09T15:03:06.924Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-38296",
    "datePublished": "2024-11-22T02:58:27.660Z",
    "dateReserved": "2024-06-13T14:41:01.525Z",
    "dateUpdated": "2024-12-09T15:03:06.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\"}, {\"lang\": \"es\", \"value\": \"Dell Edge Gateway 5200 (Coffee Lake S), versiones anteriores a 12.0.94.2380, contiene una vulnerabilidad de exposici\\u00f3n de informaci\\u00f3n confidencial en estructuras microarquitect\\u00f3nicas compartidas durante la ejecuci\\u00f3n transitoria. Un atacante con privilegios elevados y acceso local podr\\u00eda aprovechar esta vulnerabilidad, lo que provocar\\u00eda la exposici\\u00f3n de informaci\\u00f3n.\"}]",
      "id": "CVE-2024-38296",
      "lastModified": "2024-12-09T15:15:13.993",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}]}",
      "published": "2024-11-22T03:15:04.160",
      "references": "[{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability\", \"source\": \"security_alert@emc.com\"}]",
      "sourceIdentifier": "security_alert@emc.com",
      "vulnStatus": "Awaiting Analysis"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-38296\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-11-22T03:15:04.160\",\"lastModified\":\"2024-12-09T15:15:13.993\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\"},{\"lang\":\"es\",\"value\":\"Dell Edge Gateway 5200 (Coffee Lake S), versiones anteriores a 12.0.94.2380, contiene una vulnerabilidad de exposici\u00f3n de informaci\u00f3n confidencial en estructuras microarquitect\u00f3nicas compartidas durante la ejecuci\u00f3n transitoria. Un atacante con privilegios elevados y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la exposici\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}]},\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability\",\"source\":\"security_alert@emc.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-38296\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-25T18:18:21.316783Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"dell\", \"product\": \"edge_gateway_5200_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"12.0.94.2380\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-25T18:20:33.374Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Dell would like to thank the Eclypsium Research Team for reporting this issue\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Edge Gateway 5200\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"12.0.94.2380\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-11-21T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1421\", \"description\": \"CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-12-09T15:03:06.924Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-38296\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-09T15:03:06.924Z\", \"dateReserved\": \"2024-06-13T14:41:01.525Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-11-22T02:58:27.660Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.