CVE-2024-5000 (GCVE-0-2024-5000)
Vulnerability from cvelistv5 – Published: 2024-06-04 08:54 – Updated: 2024-08-01 20:55- CWE-131 - Incorrect Calculation of Buffer Size
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
guessed | |
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.10
(semver)
|
guessed | |
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
guessed | |
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.10
(semver)
|
guessed | |
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
guessed | |
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
guessed | |
| codesys | control_for_empc-a\/imx6_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_beaglebone_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_iot2000_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_linux_arm_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_linux_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_pfc200_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_plcnext_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_raspberry_pi_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_for_wago_touch_panels_600_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
||
| codesys | control_rte_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
||
| codesys | control_win_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
||
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
||
| codesys | hmi_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:44.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-5000",
"date": "2026-11-02",
"epss": "0.00569",
"percentile": "0.47096"
},
"fkie_nvd": {
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado puede utilizar un cliente OPC UA malicioso para enviar una solicitud manipulada a los productos CODESYS afectados, lo que puede provocar un DoS debido a un c\u00e1lculo incorrecto del tama\u00f1o del b\u00fafer."
}
],
"id": "CVE-2024-5000",
"lastModified": "2024-11-21T09:46:44.830",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
},
"published": "2024-06-04T09:15:09.830",
"references": [
{
"source": "info@cert.vde.com",
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"source": "info@cert.vde.com",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-131"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado puede utilizar un cliente OPC UA malicioso para enviar una solicitud manipulada a los productos CODESYS afectados, lo que puede provocar un DoS debido a un c\u00e1lculo incorrecto del tama\u00f1o del b\u00fafer."
}
],
"id": "CVE-2024-5000",
"lastModified": "2026-06-17T08:14:52.690",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-5000",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-06-04T09:15:09.830",
"references": [
{
"source": "info@cert.vde.com",
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"source": "info@cert.vde.com",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-131"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T19:49:55+00:00",
"cve": "CVE-2024-5000",
"id": "CVE-2024-5000",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-5000.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:38.104Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.