CVE-2024-54772 (GCVE-0-2024-54772)

Vulnerability from cvelistv5 – Published: 2025-02-11 00:00 – Updated: 2025-02-24 15:32
VLAI?
Summary
An issue was discovered in the Winbox service of MikroTik RouterOS long-term release v6.43.13 through v6.49.13 and stable v6.43 through v7.17.2. A patch is available in the stable release v6.49.18. A discrepancy in response size between connection attempts made with a valid username and those with an invalid username allows attackers to enumerate for valid accounts.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-54772",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-13T14:19:49.063833Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-208",
                "description": "CWE-208 Observable Timing Discrepancy",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-13T14:24:22.765Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in the Winbox service of MikroTik RouterOS long-term release v6.43.13 through v6.49.13 and stable v6.43 through v7.17.2. A patch is available in the stable release v6.49.18. A discrepancy in response size between connection attempts made with a valid username and those with an invalid username allows attackers to enumerate for valid accounts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-24T15:32:18.010Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/deauther890/CVE-2024-54772"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-54772",
    "datePublished": "2025-02-11T00:00:00.000Z",
    "dateReserved": "2024-12-06T00:00:00.000Z",
    "dateUpdated": "2025-02-24T15:32:18.010Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-54772\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-02-11T23:15:09.117\",\"lastModified\":\"2025-06-30T14:48:12.073\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in the Winbox service of MikroTik RouterOS long-term release v6.43.13 through v6.49.13 and stable v6.43 through v7.17.2. A patch is available in the stable release v6.49.18. A discrepancy in response size between connection attempts made with a valid username and those with an invalid username allows attackers to enumerate for valid accounts.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 un problema en el servicio Winbox de MikroTik RouterOS v6.43 a v7.16.1 versiones v6.43.13 hasta v6.49.13 y estables desde v6.43 hasta v7.17.2. Hay disponible un parche en la versi\u00f3n estable v6.49.18. Una discrepancia en el tama\u00f1o de respuesta entre los intentos de conexi\u00f3n realizados con un nombre de usuario v\u00e1lido y aquellos con un nombre de usuario no v\u00e1lido permite a los atacantes realizar una enumeraci\u00f3n de cuentas v\u00e1lidas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-208\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mikrotik:routeros:*:*:*:*:-:*:*:*\",\"versionStartIncluding\":\"6.43\",\"versionEndExcluding\":\"6.49.18\",\"matchCriteriaId\":\"F618C1B1-340C-4893-A0FF-23B533F787E3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mikrotik:routeros:*:*:*:*:ltr:*:*:*\",\"versionStartIncluding\":\"6.43.13\",\"versionEndIncluding\":\"6.49.13\",\"matchCriteriaId\":\"2DD4F8E4-8A7E-408E-ACF8-C7D003D78027\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mikrotik:routeros:*:*:*:*:-:*:*:*\",\"versionStartIncluding\":\"7.1\",\"versionEndExcluding\":\"7.18\",\"matchCriteriaId\":\"BD087026-C45D-44F3-A305-41A07FDB14EC\"}]}]}],\"references\":[{\"url\":\"https://github.com/deauther890/CVE-2024-54772\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"Exploit\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-54772\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-13T14:19:49.063833Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-208\", \"description\": \"CWE-208 Observable Timing Discrepancy\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T21:44:57.609Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://github.com/deauther890/CVE-2024-54772\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An issue was discovered in the Winbox service of MikroTik RouterOS long-term release v6.43.13 through v6.49.13 and stable v6.43 through v7.17.2. A patch is available in the stable release v6.49.18. A discrepancy in response size between connection attempts made with a valid username and those with an invalid username allows attackers to enumerate for valid accounts.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-02-24T15:32:18.010Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-54772\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-24T15:32:18.010Z\", \"dateReserved\": \"2024-12-06T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2025-02-11T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…