CVE-2024-9760
Vulnerability from cvelistv5
Published
2024-11-22 21:01
Modified
2024-11-23 01:26
Severity ?
EPSS score ?
Summary
Tungsten Automation Power PDF PNG File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Tungsten Automation | Power PDF |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-9760", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-23T01:20:16.717473Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-23T01:26:28.654Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Power PDF", "vendor": "Tungsten Automation", "versions": [ { "status": "affected", "version": "5.0.0.10.0.23307" } ] } ], "dateAssigned": "2024-10-09T14:44:14.671-05:00", "datePublic": "2024-10-11T16:59:02.457-05:00", "descriptions": [ { "lang": "en", "value": "Tungsten Automation Power PDF PNG File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of PNG files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-24476." } ], "metrics": [ { "cvssV3_0": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-22T21:01:58.175Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-24-1357", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1357/" } ], "source": { "lang": "en", "value": "Mat Powell of Trend Micro Zero Day Initiative" }, "title": "Tungsten Automation Power PDF PNG File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2024-9760", "datePublished": "2024-11-22T21:01:58.175Z", "dateReserved": "2024-10-09T19:44:14.645Z", "dateUpdated": "2024-11-23T01:26:28.654Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-9760\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-11-22T21:15:30.040\",\"lastModified\":\"2024-11-22T21:15:30.040\",\"vulnStatus\":\"Received\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Tungsten Automation Power PDF PNG File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\\n\\nThe specific flaw exists within the parsing of PNG files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-24476.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-1357/\",\"source\":\"zdi-disclosures@trendmicro.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.