CVE-2025-68623 (GCVE-0-2025-68623)

Vulnerability from cvelistv5 – Published: 2026-03-11 00:00 – Updated: 2026-03-11 18:26 Disputed
VLAI?
Summary
In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker's code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2026-03-11T16:20:19.379Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2293"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-68623",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-11T18:24:19.781599Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-11T18:26:58.163Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker\u0027s code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-11T16:17:39.592Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.microsoft.com/en-us/download/details.aspx?id=35"
        },
        {
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2293"
        }
      ],
      "tags": [
        "disputed"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-68623",
    "datePublished": "2026-03-11T00:00:00.000Z",
    "dateReserved": "2025-12-19T00:00:00.000Z",
    "dateUpdated": "2026-03-11T18:26:58.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-68623\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2026-03-11T17:16:52.750\",\"lastModified\":\"2026-03-12T21:08:22.643\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"disputed\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker\u0027s code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"references\":[{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2025-2293\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.microsoft.com/en-us/download/details.aspx?id=35\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2293\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2293\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2026-03-11T16:20:19.379Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-68623\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-11T18:24:19.781599Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-03-11T18:26:33.588Z\"}}], \"cna\": {\"tags\": [\"disputed\"], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.microsoft.com/en-us/download/details.aspx?id=35\"}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2025-2293\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker\u0027s code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2026-03-11T16:17:39.592Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-68623\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-11T18:26:58.163Z\", \"dateReserved\": \"2025-12-19T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2026-03-11T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…