CVE-2026-16933 (GCVE-0-2026-16933)
Vulnerability from cvelistv5 – Published: 2026-08-19 19:13 – Updated: 2026-08-22 03:55- CWE-190 - Integer Overflow or Wraparound
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283216 | vendor-advisorypatch |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) Affected: OP940.00 , ≤ OP940.a1 (semver) Affected: OP940.00 , ≤ OP940.81 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:op940.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:op940.a1:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16933",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:55:55.637Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.a1:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.a1",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.81",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T20:05:15.480Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283216"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1180 (9080-HEU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1122 (9824-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1124 (9824-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1122s (9824-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1114 (9824-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1122 (9856-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1124 (9856-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1150 (9043-MRU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1112 (9242-21B, 9242-21T)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr/\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003cbr/\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S922 (9009-22G)\u003c/li\u003e\u003cli\u003eIBM Power System H922 (9223-22S)\u003c/li\u003e\u003cli\u003eIBM Power System S914 (9009-41G)\u003c/li\u003e\u003cli\u003eIBM Power System S924 (9009-42G)\u003c/li\u003e\u003cli\u003eIBM Power System H924 (9223-42S)\u003c/li\u003e\u003cli\u003eIBM Power System E950 (9040-MR9)\u003c/li\u003e\u003cli\u003eIBM Power System E980 (9080-M9S)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install OP940.a2 or newer to remediate this vulnerability.\u003cbr/\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System AC922\u00a0(8335-GTH, 8335-GTX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install OP940.82 or newer to remediate this vulnerability.\u003cbr/\u003ePower Hardware Management Console\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power Hardware Management Console (7063-CR2)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cem\u003eThe images mentioned above can be located at IBM Fix Central : \u003c/em\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003e\u003cem\u003ehttps://www.ibm.com/support/fixcentral/\u003c/em\u003e\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System S1122 (9824-22A)\n * IBM Power System S1124 (9824-42A)\n * IBM Power System S1122s (9824-22B)\n * IBM Power System S1114 (9824-41B)\n * IBM Power System L1122 (9856-22H)\n * IBM Power System L1124 (9856-42H)\n * IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n * IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System S1022 (9105-22A)\n * IBM Power System S1024 (9105-42A)\n * IBM Power System S1022s (9105-22B)\n * IBM Power System S1014 (9105-41B)\n * IBM Power System L1022 (9786-22H)\n * IBM Power System L1024 (9786-42H)\n * IBM Power System E1050 (9043-MRX)\n * IBM Power System S1012 (9028-21B)\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System S922 (9009-22G)\n * IBM Power System H922 (9223-22S)\n * IBM Power System S914 (9009-41G)\n * IBM Power System S924 (9009-42G)\n * IBM Power System H924 (9223-42S)\n * IBM Power System E950 (9040-MR9)\n * IBM Power System E980 (9080-M9S)\n\n\nCustomers with the products below should install OP940.a2 or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System AC922\u00a0(8335-GTH, 8335-GTX)\n\n\nCustomers with the products below should install OP940.82 or newer to remediate this vulnerability.\nPower Hardware Management Console\n\n * IBM Power Hardware Management Console (7063-CR2)\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Integer Overflow"
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16933",
"datePublished": "2026-08-19T19:13:26.703Z",
"dateReserved": "2026-07-24T07:31:49.353Z",
"dateUpdated": "2026-08-22T03:55:55.637Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-16933",
"date": "2026-11-03",
"epss": "0.00169",
"percentile": "0.06259"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.a1:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.a1",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.81",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
}
]
}
],
"source": "psirt@us.ibm.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1122_\\(9824-22a\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C016EFBA-A371-4264-A823-A7635D39F6D9",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_s1122_\\(9824-22a\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "B8707806-84E4-442B-A29F-7BF44514F8DA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1122_\\(9824-22a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "96C2DEDC-012D-4B9F-B9DF-344A49B67E46",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1124_\\(9824-42a\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6B512BF5-7D6B-45EA-97B8-F22B63A62270",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_s1124_\\(9824-42a\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "25BCA648-5FF1-4B90-98ED-23E5BB217465",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1124_\\(9824-42a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "3F51514A-8E29-42D1-B874-838F8A0869D2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1122s_\\(9824-22b\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC8256E1-574D-4666-BE1B-45977348AC86",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_s1122s_\\(9824-22b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "2165EAA9-EDC9-4010-9D31-294F9414A9E6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1122s_\\(9824-22b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "26E1E16B-8F95-46EC-BAA0-0A53F332292B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1114_\\(9824-41b\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3F8C1054-A539-468C-9A5F-E6E686C6CE8A",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_s1114_\\(9824-41b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "085F1C27-D806-4E4B-A44A-BB3C056CFCF7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1114_\\(9824-41b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8688E552-BE38-4EB9-8514-D7060C548C39",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_l1122_\\(9856-22h\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "37868E6E-7759-4CCB-995E-BDB7F61F6818",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_l1122_\\(9856-22h\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "50916B93-7340-4344-AF34-91836ABE508F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_l1122_\\(9856-22h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "3C8998E4-5EA9-4C7E-BF59-644CB78D00D2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_l1124_\\(9856-42h\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F0FE92C-3510-475A-8D02-ED17ADD87CD0",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_l1124_\\(9856-42h\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "FECCD687-64E7-45B4-BCB7-AEF25164D049",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_l1124_\\(9856-42h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FB6FA2C-70A5-4F19-B64B-7502D20CFE5C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1150_\\(9043-mru\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC4CCBFC-3120-475D-BF75-025C04E41B91",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_e1150_\\(9043-mru\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "BE428FBB-4DDC-4E05-A5C3-F37BE9395723",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1150_\\(9043-mru\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "AC9D9EFF-1E92-4894-9976-001227F78869",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1112_\\(9242-21b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "6505E499-E766-451D-9996-1668BE53AAF8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1112_\\(9242-21b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3F5100A-FE2A-412C-9B57-B616B97B1142",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1112_\\(9242-21t\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "109DE27E-5F87-4BD0-8C48-F72A1C2AD55D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1112_\\(9242-21t\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "EA825307-2083-4264-8E8B-798661285261",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1080_\\(9080-hex\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA6D803F-DD5C-49A7-BE93-68981C124C69",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1080_\\(9080-hex\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF85251B-E02C-4293-98F0-D331BF51CAC4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1022_\\(9105-22a\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0BB54554-C9DC-4072-A205-EA9DD4E15688",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1022_\\(9105-22a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E3E15C41-9CBD-4F66-A176-07B3E9BBD81D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1024_\\(9105-42a\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FA4B835D-CEAB-422B-9F38-F63AF84396C3",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1024_\\(9105-42a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E49EE658-B8AE-48F7-A765-92BA3A630AA0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1022s_\\(9105-22b\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51C2576F-E4DD-4002-9E41-CF89F92E2064",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1022s_\\(9105-22b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "564A665A-7B94-40CE-A4D9-CDD0CCF52B2E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1014_\\(9105-41b\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41572D5A-C3A2-4294-9AF9-D4824675B4A3",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1014_\\(9105-41b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECD54B80-5754-4C19-AE0C-F539DEF96DCB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_l1022_\\(9786-22h\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EEBFE6F7-E6D8-47AC-B011-751FB9BC3D50",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_l1022_\\(9786-22h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2C09090-C18F-464A-8DEF-E23B5990E2A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_l1024_\\(9786-42h\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6EA818B-DC65-4F2D-9FC9-C610FFABE3DD",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_l1024_\\(9786-42h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "0170400B-89A7-4B44-9AA7-9A168C9CAE9C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1050_\\(9043-mrx\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2F04E3C9-94C6-42B0-9FBD-4AC5FEF42A1F",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1050_\\(9043-mrx\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "061D193E-84BC-4DE7-96C4-B75D11769ED5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s1012_\\(9028-21b\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0524365D-8379-4B10-B9C5-FF80EE84BA27",
"versionEndExcluding": "fw1060.81",
"versionStartIncluding": "fw1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s1012_\\(9028-21b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BED85F2-8CCB-417C-A739-23828966A036",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E8049F52-227B-4CCA-B059-5821F9B41C95",
"versionEndExcluding": "fw1110.31",
"versionStartIncluding": "fw1110.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F518B3DD-3F25-4581-9103-6CD4D8DA54C7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1180_\\(9080-heu\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BD4FC49-8120-4D4B-906A-1B6FA6B30FA2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s922_\\(9009-22g\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0C406C5A-454C-4454-861F-80E629B68418",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s922_\\(9009-22g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "95E5E77F-A5BB-46E7-B6B6-B02F242DE829",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h922_\\(9223-22s\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBE7D8B3-902D-4CD1-9F31-454E293A79B3",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h922_\\(9223-22s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7851003-8D6B-4FE8-87D7-BE968E85E448",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s914_\\(9009-41g\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD77C09F-AF62-4CD8-B64C-CDF50D696648",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s914_\\(9009-41g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "003F591A-ACCD-497E-BF8A-DE090321D778",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_s924_\\(9009-42g\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "54831AF9-D748-4649-A0ED-896341845BCD",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_s924_\\(9009-42g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "4038C5DB-DF9C-4661-9590-F6A0CD4D15D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_h924_\\(9223-42s\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64FD3222-EEFD-4533-A088-B05F04E0831D",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_h924_\\(9223-42s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "C2F0E93A-26F0-4914-8A31-3C86E64D5B8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e950_\\(9040-mr9\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C99CF91B-A98D-4795-A8AE-998713989ABE",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e950_\\(9040-mr9\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9FF58E5C-0A54-4F2F-A426-0BFD1EACE991",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_e980_\\(9080-m9s\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "272B1267-28AC-4BDB-93C4-9804DBE240E0",
"versionEndExcluding": "fw950.h3",
"versionStartIncluding": "fw950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e980_\\(9080-m9s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9BE56BD8-DB0F-4151-9428-42F1B6452D99",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_ac922_\\(8335-gth\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44419C3D-F4B6-47E7-AA12-BE5FFFF45AFF",
"versionEndExcluding": "op940.a2",
"versionStartIncluding": "op940",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_ac922_\\(8335-gth\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D95F0B5F-EFEE-4002-AB88-1DD0CE3CAC46",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_system_ac922_\\(8335-gtx\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "002F9935-0A06-422C-8D6A-2312C6430DD7",
"versionEndExcluding": "op940.a2",
"versionStartIncluding": "op940",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_ac922_\\(8335-gtx\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "30ABEAED-DCF7-4375-A3F4-06169211229A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:power_hardware_management_console_\\(7063-cr2\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A432CD98-596F-4A44-9495-FCCBE830E27F",
"versionEndExcluding": "op940.82",
"versionStartIncluding": "op940",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_hardware_management_console_\\(7063-cr2\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "1DE050A1-9070-423C-B2AA-9F23C180D0A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact."
}
],
"id": "CVE-2026-16933",
"lastModified": "2026-08-25T14:05:17.290",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.5,
"impactScore": 6.0,
"source": "psirt@us.ibm.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-16933",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-19T20:17:11.807",
"references": [
{
"source": "psirt@us.ibm.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.ibm.com/support/pages/node/7283216"
}
],
"sourceIdentifier": "psirt@us.ibm.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-190"
}
],
"source": "psirt@us.ibm.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16933",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T16:08:13.067622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-21T16:14:18.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:op940.a1:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.a1",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "OP940.81",
"status": "affected",
"version": "OP940.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T20:05:15.480Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283216"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1180 (9080-HEU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1122 (9824-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1124 (9824-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1122s (9824-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1114 (9824-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1122 (9856-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1124 (9856-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1150 (9043-MRU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1112 (9242-21B, 9242-21T)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr/\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003cbr/\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S922 (9009-22G)\u003c/li\u003e\u003cli\u003eIBM Power System H922 (9223-22S)\u003c/li\u003e\u003cli\u003eIBM Power System S914 (9009-41G)\u003c/li\u003e\u003cli\u003eIBM Power System S924 (9009-42G)\u003c/li\u003e\u003cli\u003eIBM Power System H924 (9223-42S)\u003c/li\u003e\u003cli\u003eIBM Power System E950 (9040-MR9)\u003c/li\u003e\u003cli\u003eIBM Power System E980 (9080-M9S)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install OP940.a2 or newer to remediate this vulnerability.\u003cbr/\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System AC922\u00a0(8335-GTH, 8335-GTX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install OP940.82 or newer to remediate this vulnerability.\u003cbr/\u003ePower Hardware Management Console\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power Hardware Management Console (7063-CR2)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cem\u003eThe images mentioned above can be located at IBM Fix Central : \u003c/em\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003e\u003cem\u003ehttps://www.ibm.com/support/fixcentral/\u003c/em\u003e\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System S1122 (9824-22A)\n * IBM Power System S1124 (9824-42A)\n * IBM Power System S1122s (9824-22B)\n * IBM Power System S1114 (9824-41B)\n * IBM Power System L1122 (9856-22H)\n * IBM Power System L1124 (9856-42H)\n * IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n * IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System S1022 (9105-22A)\n * IBM Power System S1024 (9105-42A)\n * IBM Power System S1022s (9105-22B)\n * IBM Power System S1014 (9105-41B)\n * IBM Power System L1022 (9786-22H)\n * IBM Power System L1024 (9786-42H)\n * IBM Power System E1050 (9043-MRX)\n * IBM Power System S1012 (9028-21B)\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System S922 (9009-22G)\n * IBM Power System H922 (9223-22S)\n * IBM Power System S914 (9009-41G)\n * IBM Power System S924 (9009-42G)\n * IBM Power System H924 (9223-42S)\n * IBM Power System E950 (9040-MR9)\n * IBM Power System E980 (9080-M9S)\n\n\nCustomers with the products below should install OP940.a2 or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System AC922\u00a0(8335-GTH, 8335-GTX)\n\n\nCustomers with the products below should install OP940.82 or newer to remediate this vulnerability.\nPower Hardware Management Console\n\n * IBM Power Hardware Management Console (7063-CR2)\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Integer Overflow"
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16933",
"datePublished": "2026-08-19T19:13:26.703Z",
"dateReserved": "2026-07-24T07:31:49.353Z",
"dateUpdated": "2026-08-22T03:55:55.637Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.