CVE-2026-40702 (GCVE-0-2026-40702)
Vulnerability from cvelistv5 – Published: 2026-06-25 20:59 – Updated: 2026-06-26 13:21| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| EVoke | EVoke CSMS |
Affected:
All versions
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40702",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-26T13:21:51.132864Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T13:21:58.641Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVoke CSMS",
"vendor": "EVoke",
"versions": [
{
"status": "affected",
"version": "All versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
}
],
"datePublic": "2026-06-26T04:18:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system."
}
],
"value": "WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-25T20:59:53.495Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://evokesystems.com/contact-us/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3."
}
],
"value": "EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected."
}
],
"value": "EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected."
}
],
"source": {
"advisory": "ICSA-26-176-02",
"discovery": "EXTERNAL"
},
"title": "EVoke Systems EVoke CSMS Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers."
}
],
"value": "EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review."
}
],
"value": "EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns."
}
],
"value": "EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible"
}
],
"value": "EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible"
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-40702",
"datePublished": "2026-06-25T20:59:53.495Z",
"dateReserved": "2026-06-18T19:23:06.055Z",
"dateUpdated": "2026-06-26T13:21:58.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-40702",
"date": "2026-11-12",
"epss": "0.00646",
"percentile": "0.51471"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "EVoke CSMS",
"vendor": "EVoke",
"versions": [
{
"status": "affected",
"version": "All versions",
"versionType": "custom"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system."
},
{
"lang": "es",
"value": "Los puntos finales de WebSocket carecen de mecanismos adecuados de autenticaci\u00f3n, lo que permite a los atacantes suplantar estaciones de carga. Como resultado, los atacantes pueden explotar esta debilidad para obtener acceso no autorizado a datos sensibles o realizar acciones no autorizadas. Dado que no se requiere autenticaci\u00f3n, esto puede conducir a la escalada de privilegios y potencialmente comprometer la seguridad de todo el sistema."
}
],
"id": "CVE-2026-40702",
"lastModified": "2026-10-25T22:10:00.150",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.5,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-40702",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-26T13:21:51.132864Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-06-25T22:17:01.483",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://evokesystems.com/contact-us/"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-02.json"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40702",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-26T13:21:51.132864Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T13:21:55.149Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVoke CSMS",
"vendor": "EVoke",
"versions": [
{
"status": "affected",
"version": "All versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
}
],
"datePublic": "2026-06-26T04:18:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system."
}
],
"value": "WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-25T20:59:53.495Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://evokesystems.com/contact-us/"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-176-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-176-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3."
}
],
"value": "EVoke states that as a hardware-agnostic platform supporting multiple charger Original Equipment Manufacturers OEMs, EVoke must interoperate with EVSE devices that support different OCPP security profiles depending on the firmware capabilities of the charger. EVoke CSMS currently supports all OCPP security profiles (0\u20133). However, the effective security configuration for a charger connection is determined by the security profile implemented in the EVSE firmware. Some legacy chargers deployed in the network support only Security Profile 0 or 1. These chargers were installed prior to the broader industry adoption of stronger authentication mechanisms defined in OCPP Security Profiles 2 and 3. EVoke is actively working with charger OEM partners to migrate supported devices to Security Profile 2 (TLS encryption with basic authentication) or Security Profile 3 (Mutual TLS authentication using client certificates). For OEMs that continue to support firmware updates, EVoke will prioritize upgrades to enable Security Profiles 2 or 3."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected."
}
],
"value": "EVoke states that certain legacy charger models deployed on the network are no longer supported by the manufacturer (for example, chargers originally produced by EVBox). These devices cannot be upgraded to support stronger security profiles. For chargers limited to Security Profiles 0 or 1, EVoke is implementing additional server-side protections to mitigate spoofing risks. Allow-listed chargers will only be accepted from chargers whose IDs are registered in the EVoke CSMS inventory database. Unknown charger identifiers will be rejected."
}
],
"source": {
"advisory": "ICSA-26-176-02",
"discovery": "EXTERNAL"
},
"title": "EVoke Systems EVoke CSMS Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers."
}
],
"value": "EVoke states that to reduce the risk of duplicate sessions, only a single active connection per charger ID will be permitted. If a second connection using the same charger ID is detected, the new connection will be rejected or the previous session will be terminated. This prevents unauthorized actors from establishing parallel sessions using spoofed charger identifiers."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review."
}
],
"value": "EVoke states that the platform will monitor session anomalies including repeated connection attempts, unexpected IP address changes, and abnormal message patterns. Security events will be logged and flagged for operational review."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns."
}
],
"value": "EVoke states that to address the risk of denial-of-service via repeated authentication attempts, EVoke will implement connection rate limiting at the WebSocket gateway layer. These controls will restrict excessive connection attempts from the same source and temporarily block abusive traffic patterns."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible"
}
],
"value": "EVoke states they are developing a lifecycle policy for legacy chargers that cannot support modern OCPP security profiles. This policy will include identification of unsupported EVSE models and risk classification Migration planning with site operators where possible"
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-40702",
"datePublished": "2026-06-25T20:59:53.495Z",
"dateReserved": "2026-06-18T19:23:06.055Z",
"dateUpdated": "2026-06-26T13:21:58.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour