CVE-2026-87675 (GCVE-0-2026-87675)

Vulnerability from cvelistv5 – Published: 2026-10-08 03:34 – Updated: 2026-10-08 13:10
VLAI
Summary
An OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-08 13:10 UTC
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
brocade CNA under the mitre root
CNA scorecard B 75/100 over 70 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Brocade Fabric OS Affected: 0 , < 9.2.2d (Brocade FabricOS)
Affected: 10.0.0 , ≤ 10.0.0a1 (Brocade FabricOS)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-87675",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-08T13:10:06.337181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-08T13:10:54.881Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "lessThan": "9.2.2d",
              "status": "affected",
              "version": "0",
              "versionType": "Brocade FabricOS"
            },
            {
              "lessThanOrEqual": "10.0.0a1",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "Brocade FabricOS"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download.\u003c/p\u003e"
            }
          ],
          "value": "An OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-08T03:34:36.578Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39146"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 9.2.2d and 10.0.1\u003c/div\u003e"
            }
          ],
          "value": "Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2026-87675",
    "datePublished": "2026-10-08T03:34:36.578Z",
    "dateReserved": "2026-09-08T22:51:12.166Z",
    "dateUpdated": "2026-10-08T13:10:54.881Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-87675",
      "date": "2026-10-08",
      "epss": "0.00733",
      "percentile": "0.52939"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Fabric OS",
                "vendor": "Brocade",
                "versions": [
                  {
                    "lessThan": "9.2.2d",
                    "status": "affected",
                    "version": "0",
                    "versionType": "Brocade FabricOS"
                  },
                  {
                    "lessThanOrEqual": "10.0.0a1",
                    "status": "affected",
                    "version": "10.0.0",
                    "versionType": "Brocade FabricOS"
                  }
                ]
              }
            ],
            "source": "sirt@brocade.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download."
          }
        ],
        "id": "CVE-2026-87675",
        "lastModified": "2026-10-08T13:17:20.390",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "sirt@brocade.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-87675",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-08T13:10:06.337181Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-10-08T04:17:55.843",
        "references": [
          {
            "source": "sirt@brocade.com",
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39146"
          }
        ],
        "sourceIdentifier": "sirt@brocade.com",
        "vulnStatus": "Received",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "sirt@brocade.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-87675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-08T13:10:06.337181Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-08T13:10:31.806Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Fabric OS",
              "vendor": "Brocade",
              "versions": [
                {
                  "lessThan": "9.2.2d",
                  "status": "affected",
                  "version": "0",
                  "versionType": "Brocade FabricOS"
                },
                {
                  "lessThanOrEqual": "10.0.0a1",
                  "status": "affected",
                  "version": "10.0.0",
                  "versionType": "Brocade FabricOS"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download.\u003c/p\u003e"
                }
              ],
              "value": "An OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-08T03:34:36.578Z",
            "orgId": "87b297d7-335e-4844-9551-11b97995a791",
            "shortName": "brocade"
          },
          "references": [
            {
              "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39146"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eSecurity update is provided in Brocade Fabric OS 9.2.2d and 10.0.1\u003c/div\u003e"
                }
              ],
              "value": "Security update is provided in Brocade Fabric OS 9.2.2d and 10.0.1"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
        "assignerShortName": "brocade",
        "cveId": "CVE-2026-87675",
        "datePublished": "2026-10-08T03:34:36.578Z",
        "dateReserved": "2026-09-08T22:51:12.166Z",
        "dateUpdated": "2026-10-08T13:10:54.881Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…