ICSA-21-222-05
Vulnerability from csaf_cisa
Published
2021-08-10 00:00
Modified
2022-04-14 00:00
Summary
Siemens Industrial Products Intel CPUs (Update F)

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could lead to unauthorized access to sensitive data, privilege escalation, and configuration change.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "Siemens",
        "summary": "reporting these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities could lead to unauthorized access to sensitive data, privilege escalation, and configuration change.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "external",
        "summary": "SSA-309571: IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021) - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-309571.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-21-222-05 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-05.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-21-222-05 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-05"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams_0905.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-309571: IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021) - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-309571.html"
      },
      {
        "category": "external",
        "summary": "SSA-309571: IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021) - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-309571: IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021) - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-309571.txt"
      }
    ],
    "title": "Siemens Industrial Products Intel CPUs (Update F)",
    "tracking": {
      "current_release_date": "2022-04-14T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-21-222-05",
      "initial_release_date": "2021-08-10T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2021-08-10T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-21-222-05 Siemens Industrial Products Intel CPUs"
        },
        {
          "date": "2022-02-10T00:00:00.000000Z",
          "legacy_version": "A",
          "number": "2",
          "summary": "ICSA-21-222-05 Siemens Industrial Products Intel CPUs (Update A)"
        },
        {
          "date": "2022-03-10T00:00:00.000000Z",
          "legacy_version": "B",
          "number": "3",
          "summary": "ICSA-21-222-05 Siemens Industrial Products Intel CPUs (Update B)"
        },
        {
          "date": "2022-04-14T00:00:00.000000Z",
          "legacy_version": "C",
          "number": "4",
          "summary": "ICSA-21-222-05 Siemens Industrial Products Intel CPUs (Update C)"
        }
      ],
      "status": "final",
      "version": "4"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Drive Controller family",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Drive Controller family"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V0209_0105",
                "product": {
                  "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV22.01.10",
                "product": {
                  "name": "SIMATIC Field PG M5",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV26.01.08",
                "product": {
                  "name": "SIMATIC Field PG M6",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV27.01.07",
                "product": {
                  "name": "SIMATIC IPC127E",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC127E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV01.04.00",
                "product": {
                  "name": "SIMATIC IPC3000 SMART V3",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC3000 SMART V3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV01.04.00",
                "product": {
                  "name": "SIMATIC IPC347G",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC347G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV21.01.16",
                "product": {
                  "name": "SIMATIC IPC427E",
                  "product_id": "CSAFPID-0008"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV21.01.16",
                "product": {
                  "name": "SIMATIC IPC477E",
                  "product_id": "CSAFPID-0009"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV21.01.16",
                "product": {
                  "name": "SIMATIC IPC477E Pro",
                  "product_id": "CSAFPID-00010"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E Pro"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC527G",
                  "product_id": "CSAFPID-00011"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC527G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC547G",
                  "product_id": "CSAFPID-00012"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC547G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.10",
                "product": {
                  "name": "SIMATIC IPC627E",
                  "product_id": "CSAFPID-00013"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.10",
                "product": {
                  "name": "SIMATIC IPC647E",
                  "product_id": "CSAFPID-00014"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.10",
                "product": {
                  "name": "SIMATIC IPC677E",
                  "product_id": "CSAFPID-00015"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.10",
                "product": {
                  "name": "SIMATIC IPC847E",
                  "product_id": "CSAFPID-00016"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV23.01.10",
                "product": {
                  "name": "SIMATIC ITP1000",
                  "product_id": "CSAFPID-00017"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITP1000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (MLFB: 6ES7518-4AX00-1AC0, 6AG1518-4AX00-4AC0, incl. SIPLUS variant)",
                  "product_id": "CSAFPID-00018"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (MLFB: 6ES7518-4AX00-1AC0, 6AG1518-4AX00-4AC0, incl. SIPLUS variant)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
                  "product_id": "CSAFPID-00019",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6ES7518-4FX00-1AC0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV08.00.00.00",
                "product": {
                  "name": "SINUMERIK 828D HW PU.4",
                  "product_id": "CSAFPID-00020"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 828D HW PU.4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV05.00.00.00",
                "product": {
                  "name": "SINUMERIK MC MCU 1720",
                  "product_id": "CSAFPID-00021"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK MC MCU 1720"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV08.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10",
                  "product_id": "CSAFPID-00022"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV05.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE NCU 1740",
                  "product_id": "CSAFPID-00023"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE NCU 1740"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV06.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE PPU 1740",
                  "product_id": "CSAFPID-00024"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE PPU 1740"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-8670",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Race condition in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8670"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-8670"
    },
    {
      "cve": "CVE-2020-8703",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper buffer restrictions in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 and 15.0.22 may allow a privileged user to potentially enable escalation of privilege via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8703"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.10 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-8703"
    },
    {
      "cve": "CVE-2020-8704",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Race condition in a subsystem in the Intel(R) LMS versions before 2039.1.0.0 may allow a privileged user to potentially enable escalation of privilege via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8704"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.10 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-8704"
    },
    {
      "cve": "CVE-2020-12357",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper initialization in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00018",
          "CSAFPID-00019",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-12357"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "CSAFPID-00018",
            "CSAFPID-00019"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-12357"
    },
    {
      "cve": "CVE-2020-12358",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Out of bounds write in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable denial of service via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00012",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-12358"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-12358"
    },
    {
      "cve": "CVE-2020-12360",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Out of bounds read in the firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00012",
          "CSAFPID-00018",
          "CSAFPID-00019",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-12360"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "CSAFPID-00018",
            "CSAFPID-00019"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-12360"
    },
    {
      "cve": "CVE-2020-24486",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper input validation in the firmware for some Intel(R) Processors may allow an authenticated user to potentially enable denial of service via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00012",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24486"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00012",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24486"
    },
    {
      "cve": "CVE-2020-24506",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Out of bound read in a subsystem in the Intel(R) CSME versions before 12.0.81, 13.0.47, 13.30.17, 14.1.53 and 14.5.32 may allow a privileged user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24506"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24506"
    },
    {
      "cve": "CVE-2020-24507",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24507"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.10 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.0,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24507"
    },
    {
      "cve": "CVE-2020-24511",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper isolation of shared resources in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24511"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24511"
    },
    {
      "cve": "CVE-2020-24512",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Observable timing discrepancy in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24512"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.10 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.16 or later version",
          "product_ids": [
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.10 or later version",
          "product_ids": [
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.10 or later version",
          "product_ids": [
            "CSAFPID-00017"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 2.8,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24512"
    },
    {
      "cve": "CVE-2020-24513",
      "cwe": {
        "id": "CWE-311",
        "name": "Missing Encryption of Sensitive Data"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Domain-bypass transient execution vulnerability in some Intel Atom(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-00020",
          "CSAFPID-00021",
          "CSAFPID-00022",
          "CSAFPID-00023",
          "CSAFPID-00024"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24513"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V0209_0105 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109743969/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V27.01.07 or later version",
          "product_ids": [
            "CSAFPID-0005"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020",
            "CSAFPID-00022"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00021"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00024"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your\r\nlocal Siemens account manager.",
          "product_ids": [
            "CSAFPID-00023"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V01.04.00 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-00020",
            "CSAFPID-00021",
            "CSAFPID-00022",
            "CSAFPID-00023",
            "CSAFPID-00024"
          ]
        }
      ],
      "title": "CVE-2020-24513"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.