SSA-489698
Vulnerability from csaf_siemens
Published
2024-05-14 00:00
Modified
2024-05-14 00:00
Summary
SSA-489698: X_T File Parsing Vulnerability in Parasolid

Notes

Summary
Parasolid is affected by an out of bounds write vulnerability that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Parasolid is affected by an out of bounds write vulnerability that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-489698: X_T File Parsing Vulnerability in Parasolid - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"
      },
      {
        "category": "self",
        "summary": "SSA-489698: X_T File Parsing Vulnerability in Parasolid - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-489698.json"
      },
      {
        "category": "self",
        "summary": "SSA-489698: X_T File Parsing Vulnerability in Parasolid - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-489698.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-489698: X_T File Parsing Vulnerability in Parasolid - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-489698.txt"
      }
    ],
    "title": "SSA-489698: X_T File Parsing Vulnerability in Parasolid",
    "tracking": {
      "current_release_date": "2024-05-14T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-489698",
      "initial_release_date": "2024-05-14T00:00:00Z",
      "revision_history": [
        {
          "date": "2024-05-14T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV35.1.256",
                "product": {
                  "name": "Parasolid V35.1",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V35.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV36.0.210",
                "product": {
                  "name": "Parasolid V36.0",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V36.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV36.1.185",
                "product": {
                  "name": "Parasolid V36.1",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V36.1"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-31980",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Do not open untrusted X_T files in Parasolid",
          "product_ids": [
            "1",
            "2",
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V35.1.256 or later version",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V36.0.210 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V36.1.185 or later version",
          "product_ids": [
            "3"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3"
          ]
        }
      ],
      "title": "CVE-2024-31980"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.