cve-2013-0675
Vulnerability from cvelistv5
Published
2013-03-21 15:00
Modified
2024-09-16 19:36
Severity
Summary
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
Impacted products
VendorProduct
n/an/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-03-21T15:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0675",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf"
            },
            {
              "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0675",
    "datePublished": "2013-03-21T15:00:00Z",
    "dateReserved": "2012-12-19T00:00:00Z",
    "dateUpdated": "2024-09-16T19:36:20.713Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2013-0675\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-03-21T15:55:01.553\",\"lastModified\":\"2013-03-22T13:52:30.073\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en CCEServer (tambi\u00e9n conocido como el componente central de comunicaciones) en Siemens WinCC antes de v7,2, tal como se utiliza en SIMATIC PCS v7 antes de v8,0 SP1 y otros productos, permite a atacantes remotos provocar una denegaci\u00f3n de servicio a trav\u00e9s de un paquete dise\u00f1ado.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:N/I:N/A:C\",\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":6.1},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.5,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.0\",\"matchCriteriaId\":\"6EFF12A0-B105-4225-B818-F858C75047B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"33FA164B-E269-4140-AC85-2623356AF636\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.1\",\"matchCriteriaId\":\"B34F3397-62D2-4D9C-A3DA-1BEE4A2A69FC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4CB277F-7ECB-4F44-8BB5-A3D350486EE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"616535F1-F609-408B-AE48-61ACF48748A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F322FCB-32F4-4C5A-A7F5-F7EF41188C88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"69822DB4-DC79-4F88-A470-5AC512C77377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"996DE8BD-DD51-41EF-9882-C2BD2CC5FE53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"945C8B46-4CDA-4143-889C-30E30E93DB29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"111D0F4D-2B67-46E8-BF8D-5D30EFE561EE\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...