CVE-2015-1449 (GCVE-0-2015-1449)
Vulnerability from cvelistv5
Published
2015-02-02 15:00
Modified
2024-08-06 04:40
Severity ?
Summary
Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-06T04:40:18.588Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         datePublic: "2015-02-02T00:00:00",
         descriptions: [
            {
               lang: "en",
               value: "Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2015-02-02T14:57:00",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "cve@mitre.org",
               ID: "CVE-2015-1449",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "n/a",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "n/a",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "n/a",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "n/a",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf",
                     refsource: "CONFIRM",
                     url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2015-1449",
      datePublished: "2015-02-02T15:00:00",
      dateReserved: "2015-02-02T00:00:00",
      dateUpdated: "2024-08-06T04:40:18.588Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:ruggedcom_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"bs4.4.4621.31\", \"matchCriteriaId\": \"E51B0A74-0ABC-4F11-8AF4-760E24B99ED0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:ruggedcom_win7000:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8F23B406-A9E1-49F2-AE03-8BB5FDFA1BA2\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:ruggedcom_win7200:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E24FC3ED-D104-4585-8C4D-CE7CC59747D8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:ruggedcom_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"ss4.4.4624.34\", \"matchCriteriaId\": \"3D3E7749-1A38-4D61-A24E-A44E02A06012\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:ruggedcom_win5100:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FE4B24D-D4CE-47ED-9C35-5104665131A9\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:ruggedcom_win5200:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7B1947AE-3177-4F9C-97F5-4E99F0A19035\"}]}]}]",
         descriptions: "[{\"lang\": \"en\", \"value\": \"Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de buffer en el servidor web integrado en los dispositivos Siemens Ruggedcom WIN51xx con firmware anterior a SS4.4.4624.35, los dispositivos WIN52xx con firmware anterior a SS4.4.4624.35, los dispositivos WIN70xx con firmware anterior a BS4.4.4621.32, y los dispositivos WIN72xx con firmware anterior a BS4.4.4621.32 permite a atacantes remotos ejecutar c\\u00f3digo arbitrario a trav\\u00e9s de vectores no especificados.\"}]",
         id: "CVE-2015-1449",
         lastModified: "2024-11-21T02:25:26.917",
         metrics: "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": true, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
         published: "2015-02-02T15:59:09.223",
         references: "[{\"url\": \"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
         sourceIdentifier: "cve@mitre.org",
         vulnStatus: "Modified",
         weaknesses: "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2015-1449\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2015-02-02T15:59:09.223\",\"lastModified\":\"2025-04-12T10:46:40.837\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer en el servidor web integrado en los dispositivos Siemens Ruggedcom WIN51xx con firmware anterior a SS4.4.4624.35, los dispositivos WIN52xx con firmware anterior a SS4.4.4624.35, los dispositivos WIN70xx con firmware anterior a BS4.4.4621.32, y los dispositivos WIN72xx con firmware anterior a BS4.4.4621.32 permite a atacantes remotos ejecutar código arbitrario a través de vectores no especificados.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":true,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ruggedcom_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"bs4.4.4621.31\",\"matchCriteriaId\":\"E51B0A74-0ABC-4F11-8AF4-760E24B99ED0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_win7000:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F23B406-A9E1-49F2-AE03-8BB5FDFA1BA2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_win7200:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E24FC3ED-D104-4585-8C4D-CE7CC59747D8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ruggedcom_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"ss4.4.4624.34\",\"matchCriteriaId\":\"3D3E7749-1A38-4D61-A24E-A44E02A06012\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_win5100:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FE4B24D-D4CE-47ED-9C35-5104665131A9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_win5200:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B1947AE-3177-4F9C-97F5-4E99F0A19035\"}]}]}],\"references\":[{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-753139.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.