CVE-2016-6411 (GCVE-0-2016-6411)

Vulnerability from cvelistv5 – Published: 2016-09-24 01:00 – Updated: 2024-08-06 01:29
VLAI
Summary
Cisco Firepower Management Center and FireSIGHT System Software 6.0.1 mishandle comparisons between URLs and X.509 certificates, which allows remote attackers to bypass intended do-not-decrypt settings via a crafted URL, aka Bug ID CSCva50585.
CWE
  • n/a
References
URL Tags
http://www.securitytracker.com/id/1036877 vdb-entryx_refsource_SECTRACK
http://tools.cisco.com/security/center/content/Ci… vendor-advisoryx_refsource_CISCO
Date Public
2016-09-21 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:29:20.141Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1036877",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1036877"
          },
          {
            "name": "20160921 Cisco Firepower Management Center and FireSIGHT System Software SSLIinspection Bypass Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-09-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco Firepower Management Center and FireSIGHT System Software 6.0.1 mishandle comparisons between URLs and X.509 certificates, which allows remote attackers to bypass intended do-not-decrypt settings via a crafted URL, aka Bug ID CSCva50585."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-29T09:57:01.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "1036877",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1036877"
        },
        {
          "name": "20160921 Cisco Firepower Management Center and FireSIGHT System Software SSLIinspection Bypass Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2016-6411",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco Firepower Management Center and FireSIGHT System Software 6.0.1 mishandle comparisons between URLs and X.509 certificates, which allows remote attackers to bypass intended do-not-decrypt settings via a crafted URL, aka Bug ID CSCva50585."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1036877",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1036877"
            },
            {
              "name": "20160921 Cisco Firepower Management Center and FireSIGHT System Software SSLIinspection Bypass Vulnerability",
              "refsource": "CISCO",
              "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2016-6411",
    "datePublished": "2016-09-24T01:00:00.000Z",
    "dateReserved": "2016-07-26T00:00:00.000Z",
    "dateUpdated": "2024-08-06T01:29:20.141Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2016-6411",
      "date": "2026-09-25",
      "epss": "0.00749",
      "percentile": "0.52981"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:cisco:firesight_system_software:6.0.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DC5565FE-174C-41C7-9462-9138BB31507D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco Firepower Management Center and FireSIGHT System Software 6.0.1 mishandle comparisons between URLs and X.509 certificates, which allows remote attackers to bypass intended do-not-decrypt settings via a crafted URL, aka Bug ID CSCva50585."
        },
        {
          "lang": "es",
          "value": "Cisco Firepower Management Center y FireSIGHT System Software 6.0.1 maneja de forma incorrecta las comparaciones entre URLs y certificados X.509, lo que permite a atacantes remotos eludir configuraciones destinadas al no-descifrado a trav\u00e9s de una URL manipulada, vulnerabilidad tambi\u00e9n conocida como Bug ID CSCva50585."
        }
      ],
      "id": "CVE-2016-6411",
      "lastModified": "2024-11-21T02:56:04.757",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2016-09-24T01:59:04.057",
      "references": [
        {
          "source": "ykramarz@cisco.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
        },
        {
          "source": "ykramarz@cisco.com",
          "url": "http://www.securitytracker.com/id/1036877"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.securitytracker.com/id/1036877"
        }
      ],
      "sourceIdentifier": "ykramarz@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:cisco:firesight_system_software:6.0.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DC5565FE-174C-41C7-9462-9138BB31507D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Cisco Firepower Management Center and FireSIGHT System Software 6.0.1 mishandle comparisons between URLs and X.509 certificates, which allows remote attackers to bypass intended do-not-decrypt settings via a crafted URL, aka Bug ID CSCva50585."
          },
          {
            "lang": "es",
            "value": "Cisco Firepower Management Center y FireSIGHT System Software 6.0.1 maneja de forma incorrecta las comparaciones entre URLs y certificados X.509, lo que permite a atacantes remotos eludir configuraciones destinadas al no-descifrado a trav\u00e9s de una URL manipulada, vulnerabilidad tambi\u00e9n conocida como Bug ID CSCva50585."
          }
        ],
        "id": "CVE-2016-6411",
        "lastModified": "2026-05-06T22:30:45.220",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2016-09-24T01:59:04.057",
        "references": [
          {
            "source": "psirt@cisco.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
          },
          {
            "source": "psirt@cisco.com",
            "url": "http://www.securitytracker.com/id/1036877"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160921-fmc"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.securitytracker.com/id/1036877"
          }
        ],
        "sourceIdentifier": "psirt@cisco.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…