cve-2016-8370
Vulnerability from cvelistv5
Published
2017-02-13 21:00
Modified
2024-08-06 02:20
Severity ?
EPSS score ?
Summary
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/94632 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T02:20:30.810Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03" }, { "name": "94632", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94632" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module" } ] } ], "datePublic": "2017-02-13T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC." } ], "problemTypes": [ { "descriptions": [ { "description": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module weak encryption", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-02-14T10:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03" }, { "name": "94632", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94632" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2016-8370", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module", "version": { "version_data": [ { "version_value": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Mitsubishi Electric MELSEC-Q Series Ethernet Interface Module weak encryption" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03" }, { "name": "94632", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94632" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2016-8370", "datePublished": "2017-02-13T21:00:00", "dateReserved": "2016-09-28T00:00:00", "dateUpdated": "2024-08-06T02:20:30.810Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-8370\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-02-13T21:59:01.220\",\"lastModified\":\"2021-09-13T11:13:36.640\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.\"},{\"lang\":\"es\",\"value\":\"Ha sido descubierto un problema en las series Mitsubishi Electric Automation MELSEC-Q en m\u00f3dulos de interfaz Ethernet QJ71E71-100, todas las versiones, QJ71E71-B5, todas las versiones y QJ71E71-B2, todas las versiones. Las contrase\u00f1as cifradas d\u00e9bilmente son transmitidas a un MELSEC-Q PLC.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:qj71e71-100_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B02D732B-25E3-4D8A-872B-EC655195DE44\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:qj71e71-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FD1EB30-B1FC-49CC-97D7-739AA5E92E86\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:qj71e71-b5_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"579FA375-1A72-4A5D-BC3E-285CBA5BD1A2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:qj71e71-b5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6C571AE-9A2B-4673-90C1-A369B91E74FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:qj71e71-b2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DA33198-3964-490A-B4CE-388FC4C585FE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:qj71e71-b2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCB98436-7C3D-480C-927B-1D55DB1404B7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/94632\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-336-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.