cve-2017-3578
Vulnerability from cvelistv5
Published
2017-04-24 19:00
Modified
2024-10-04 19:20
Severity ?
EPSS score ?
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
References
▼ | URL | Tags | |
---|---|---|---|
secalert_us@oracle.com | http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html | Vendor Advisory | |
secalert_us@oracle.com | http://www.securityfocus.com/bid/97810 | Third Party Advisory, VDB Entry | |
secalert_us@oracle.com | http://www.securitytracker.com/id/1038292 |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T14:30:57.994Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html" }, { "name": "1038292", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038292" }, { "name": "97810", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/97810" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2017-3578", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-04T16:22:07.505492Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-04T19:20:10.767Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Sun ZFS Storage Appliance Kit (AK) Software", "vendor": "Oracle Corporation", "versions": [ { "status": "affected", "version": "AK 2013" } ] } ], "datePublic": "2017-04-18T00:00:00", "descriptions": [ { "lang": "en", "value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)." } ], "problemTypes": [ { "descriptions": [ { "description": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-07-10T09:57:01", "orgId": "43595867-4340-4103-b7a2-9a5208d29a85", "shortName": "oracle" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html" }, { "name": "1038292", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038292" }, { "name": "97810", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/97810" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secalert_us@oracle.com", "ID": "CVE-2017-3578", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Sun ZFS Storage Appliance Kit (AK) Software", "version": { "version_data": [ { "version_affected": "=", "version_value": "AK 2013" } ] } } ] }, "vendor_name": "Oracle Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)." } ] } ] }, "references": { "reference_data": [ { "name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html", "refsource": "CONFIRM", "url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html" }, { "name": "1038292", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1038292" }, { "name": "97810", "refsource": "BID", "url": "http://www.securityfocus.com/bid/97810" } ] } } } }, "cveMetadata": { "assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85", "assignerShortName": "oracle", "cveId": "CVE-2017-3578", "datePublished": "2017-04-24T19:00:00", "dateReserved": "2016-12-06T00:00:00", "dateUpdated": "2024-10-04T19:20:10.767Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-3578\",\"sourceIdentifier\":\"secalert_us@oracle.com\",\"published\":\"2017-04-24T19:59:05.317\",\"lastModified\":\"2019-10-03T00:03:26.223\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \\\"exploitable\\\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: RAS subsystems). La versi\u00f3n soportada afectada es AK 2013. Vulnerabilidad f\u00e1cil explotable permite que un atacante con privilegios bajos con inicio de sesi\u00f3n en la infraestructura en la que Sun ZFS Storage Appliance Kit (AK) ejecute el compromiso de Sun ZFS Storage Appliance Kit (AK). Aunque la vulnerabilidad se encuentra en el Kit de dispositivos de almacenamiento de Sun ZFS, los ataques pueden afectar significativamente a otros productos. Los ataques exitosos de esta vulnerabilidad pueden resultar en la adquisici\u00f3n de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Puntuaci\u00f3n Base 8.8 (Confidencialidad, Integridad e Impactos de disponibilidad). Vector CVSS: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit_software:2013:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D06E5C2E-66BF-434F-9137-B256450C00EE\"}]}]}],\"references\":[{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/97810\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1038292\",\"source\":\"secalert_us@oracle.com\"}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.