CVE-2017-3580 (GCVE-0-2017-3580)
Vulnerability from cvelistv5 – Published: 2017-04-24 19:00 – Updated: 2024-10-04 19:19- Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
| URL | Tags |
|---|---|
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/97830 | vdb-entryx_refsource_BID |
| http://www.securitytracker.com/id/1038292 | vdb-entryx_refsource_SECTRACK |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:30:58.940Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038292"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-3580",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T16:22:06.477248Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:19:58.486Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-04-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-10T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038292"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-3580",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038292"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-3580",
"datePublished": "2017-04-24T19:00:00.000Z",
"dateReserved": "2016-12-06T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:19:58.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-3580",
"date": "2026-11-16",
"epss": "0.02014",
"percentile": "0.81225"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit:ak_2013:*:*:*:*:*:*:*",
"matchCriteriaId": "D9B7B268-6120-4030-9EC6-39608F403352",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
},
{
"lang": "es",
"value": "Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: RAS subsystems). La versi\u00f3n soportada que se ve afectada es AK 2013. Dif\u00edcil de explotar la vulnerabilidad permite un atacante no autenticado con acceso a la red a trav\u00e9s de m\u00faltiples protocolos para comprometer Sun ZFS Storage Appliance Kit (AK). Los ataques exitosos requieren una interacci\u00f3n humana de una persona m\u00e1s que un atacante y aunque la vulnerabilidad est\u00e1 en el Kit de Dispositivos de Almacenamiento Sun ZFS, los ataques pueden afectar significativamente a otros productos. Los ataques exitosos de esta vulnerabilidad pueden resultar en la adquisici\u00f3n de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidencialidad, Integridad y Impactos de disponibilidad). Vector CVSS: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"id": "CVE-2017-3580",
"lastModified": "2024-11-21T03:25:51.560",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 4.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.6,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-04-24T19:59:05.380",
"references": [
{
"source": "secalert_us@oracle.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"source": "secalert_us@oracle.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"source": "secalert_us@oracle.com",
"url": "http://www.securitytracker.com/id/1038292"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securitytracker.com/id/1038292"
}
],
"sourceIdentifier": "secalert_us@oracle.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit:ak_2013:*:*:*:*:*:*:*",
"matchCriteriaId": "D9B7B268-6120-4030-9EC6-39608F403352",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
},
{
"lang": "es",
"value": "Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: RAS subsystems). La versi\u00f3n soportada que se ve afectada es AK 2013. Dif\u00edcil de explotar la vulnerabilidad permite un atacante no autenticado con acceso a la red a trav\u00e9s de m\u00faltiples protocolos para comprometer Sun ZFS Storage Appliance Kit (AK). Los ataques exitosos requieren una interacci\u00f3n humana de una persona m\u00e1s que un atacante y aunque la vulnerabilidad est\u00e1 en el Kit de Dispositivos de Almacenamiento Sun ZFS, los ataques pueden afectar significativamente a otros productos. Los ataques exitosos de esta vulnerabilidad pueden resultar en la adquisici\u00f3n de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidencialidad, Integridad y Impactos de disponibilidad). Vector CVSS: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"id": "CVE-2017-3580",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 4.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.6,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-04-24T19:59:05.380",
"references": [
{
"source": "secalert_us@oracle.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"source": "secalert_us@oracle.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"source": "secalert_us@oracle.com",
"url": "http://www.securitytracker.com/id/1038292"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securitytracker.com/id/1038292"
}
],
"sourceIdentifier": "secalert_us@oracle.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:30:58.940Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038292"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-3580",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T16:22:06.477248Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T16:22:11.449Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-04-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-10T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038292"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-3580",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "97830",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97830"
},
{
"name": "1038292",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038292"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-3580",
"datePublished": "2017-04-24T19:00:00.000Z",
"dateReserved": "2016-12-06T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:19:58.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.