CVE-2017-3871 (GCVE-0-2017-3871)

Vulnerability from cvelistv5 – Published: 2017-03-17 22:00 – Updated: 2024-08-05 14:39
VLAI
Summary
A RADIUS Secret Disclosure vulnerability in the web network management interface of Cisco Prime Optical for Service Providers could allow an authenticated, remote attacker to disclose sensitive information in the configuration generated for a device. The attacker must have valid credentials for the device. More Information: CSCvc65257. Known Affected Releases: 10.6(0.1).
CWE
  • RADIUS Secret Disclosure Vulnerability
Assigner
cisco CNA under the mitre root
CNA scorecard C 66/100 over 431 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
n/a Cisco Prime Optical for Service Providers Affected: Cisco Prime Optical for Service Providers
Date Public
2017-03-17 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:39:41.178Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "96928",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96928"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Prime Optical for Service Providers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco Prime Optical for Service Providers"
            }
          ]
        }
      ],
      "datePublic": "2017-03-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A RADIUS Secret Disclosure vulnerability in the web network management interface of Cisco Prime Optical for Service Providers could allow an authenticated, remote attacker to disclose sensitive information in the configuration generated for a device. The attacker must have valid credentials for the device. More Information: CSCvc65257. Known Affected Releases: 10.6(0.1)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "RADIUS Secret Disclosure Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-03-20T09:57:01.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "96928",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96928"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2017-3871",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Prime Optical for Service Providers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco Prime Optical for Service Providers"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A RADIUS Secret Disclosure vulnerability in the web network management interface of Cisco Prime Optical for Service Providers could allow an authenticated, remote attacker to disclose sensitive information in the configuration generated for a device. The attacker must have valid credentials for the device. More Information: CSCvc65257. Known Affected Releases: 10.6(0.1)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "RADIUS Secret Disclosure Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "96928",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96928"
            },
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2017-3871",
    "datePublished": "2017-03-17T22:00:00.000Z",
    "dateReserved": "2016-12-21T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:39:41.178Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-3871",
      "date": "2026-11-15",
      "epss": "0.00941",
      "percentile": "0.61508"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:cisco:prime_optical:10.6\\(0.1\\):*:*:*:*:*:*:*",
                  "matchCriteriaId": "CEACC2B8-15CC-4418-AFB3-5B3FDDF8B6FE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A RADIUS Secret Disclosure vulnerability in the web network management interface of Cisco Prime Optical for Service Providers could allow an authenticated, remote attacker to disclose sensitive information in the configuration generated for a device. The attacker must have valid credentials for the device. More Information: CSCvc65257. Known Affected Releases: 10.6(0.1)."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de divulgaci\u00f3n secreta de RADIUS en la interfaz de administraci\u00f3n de red web de Cisco Prime Optical Communications Manager podr\u00eda permitir a un atacante remoto autenticado revelar informaci\u00f3n sensible en la configuraci\u00f3n generada para un dispositivo. El atacante debe tener credenciales v\u00e1lidas para el dispositivo. M\u00e1s informaci\u00f3n: CSCvc65257. Lanzamientos afectados conocidos: 10,6 (0,1)."
        }
      ],
      "id": "CVE-2017-3871",
      "lastModified": "2024-11-21T03:26:17.140",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2017-03-17T22:59:00.377",
      "references": [
        {
          "source": "ykramarz@cisco.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/96928"
        },
        {
          "source": "ykramarz@cisco.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/96928"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
        }
      ],
      "sourceIdentifier": "ykramarz@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:cisco:prime_optical:10.6\\(0.1\\):*:*:*:*:*:*:*",
                    "matchCriteriaId": "CEACC2B8-15CC-4418-AFB3-5B3FDDF8B6FE",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A RADIUS Secret Disclosure vulnerability in the web network management interface of Cisco Prime Optical for Service Providers could allow an authenticated, remote attacker to disclose sensitive information in the configuration generated for a device. The attacker must have valid credentials for the device. More Information: CSCvc65257. Known Affected Releases: 10.6(0.1)."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad de divulgaci\u00f3n secreta de RADIUS en la interfaz de administraci\u00f3n de red web de Cisco Prime Optical Communications Manager podr\u00eda permitir a un atacante remoto autenticado revelar informaci\u00f3n sensible en la configuraci\u00f3n generada para un dispositivo. El atacante debe tener credenciales v\u00e1lidas para el dispositivo. M\u00e1s informaci\u00f3n: CSCvc65257. Lanzamientos afectados conocidos: 10,6 (0,1)."
          }
        ],
        "id": "CVE-2017-3871",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 1.4,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-03-17T22:59:00.377",
        "references": [
          {
            "source": "psirt@cisco.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/96928"
          },
          {
            "source": "psirt@cisco.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/96928"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170315-cpo"
          }
        ],
        "sourceIdentifier": "psirt@cisco.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-200"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.