CVE-2017-7969 (GCVE-0-2017-7969)

Vulnerability from cvelistv5 – Published: 2017-09-25 19:00 – Updated: 2024-09-17 01:30
VLAI?
Summary
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
Severity ?
No CVSS data available.
CWE
  • Cross Site Request Forgery
Assigner
Impacted products
Vendor Product Version
Schneider Electric SE PowerSCADA Anywhere Affected: Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99913",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99913"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerSCADA Anywhere",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
            }
          ]
        },
        {
          "product": "Citect Anywhere",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "version 1.0"
            }
          ]
        }
      ],
      "datePublic": "2017-06-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross Site Request Forgery",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-26T09:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "name": "99913",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99913"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2017-06-22T00:00:00",
          "ID": "CVE-2017-7969",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerSCADA Anywhere",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Citect Anywhere",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "version 1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross Site Request Forgery"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99913",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99913"
            },
            {
              "name": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
              "refsource": "CONFIRM",
              "url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
            },
            {
              "name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2017-7969",
    "datePublished": "2017-09-25T19:00:00Z",
    "dateReserved": "2017-04-19T00:00:00",
    "dateUpdated": "2024-09-17T01:30:49.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6445511E-70B8-4E03-A178-FFDBE02E1609\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AE171A71-B1AF-471B-9D27-07D4491D05B3\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D2A3FA74-D201-41AA-BDA1-82816813AD11\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5182F21D-1DF5-492A-9A3D-B913AC6B12F6\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de Cross-Site Request Forgery (CSRF) en el componente Secure Gateway de PowerSCADA Anywhere v1.0 redistribuido con PowerSCADA Expert v8.1 y PowerSCADA Expert v8.2 y Citect Anywhere versi\\u00f3n 1.0, de Schneider Electric para m\\u00faltiples peticiones de cambio de estado. Este tipo de ataque requiere cierto nivel de ingenier\\u00eda social para conseguir que un usuario leg\\u00edtimo haga clic o acceda a un enlace o p\\u00e1gina maliciosa que contenga el ataque CSRF.\"}]",
      "id": "CVE-2017-7969",
      "lastModified": "2024-11-21T03:33:04.120",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2017-09-26T01:29:03.460",
      "references": "[{\"url\": \"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99913\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Issue Tracking\", \"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99913\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Issue Tracking\", \"Mitigation\", \"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-7969\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2017-09-26T01:29:03.460\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de Cross-Site Request Forgery (CSRF) en el componente Secure Gateway de PowerSCADA Anywhere v1.0 redistribuido con PowerSCADA Expert v8.1 y PowerSCADA Expert v8.2 y Citect Anywhere versi\u00f3n 1.0, de Schneider Electric para m\u00faltiples peticiones de cambio de estado. Este tipo de ataque requiere cierto nivel de ingenier\u00eda social para conseguir que un usuario leg\u00edtimo haga clic o acceda a un enlace o p\u00e1gina maliciosa que contenga el ataque CSRF.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6445511E-70B8-4E03-A178-FFDBE02E1609\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE171A71-B1AF-471B-9D27-07D4491D05B3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2A3FA74-D201-41AA-BDA1-82816813AD11\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5182F21D-1DF5-492A-9A3D-B913AC6B12F6\"}]}]}],\"references\":[{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99913\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Issue Tracking\",\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99913\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…