CVE-2018-0088 (GCVE-0-2018-0088)
Vulnerability from cvelistv5 – Published: 2018-01-18 06:00 – Updated: 2024-12-02 21:46
VLAI?
Summary
A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:14:16.304Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess"
},
{
"name": "1040240",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1040240"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-0088",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T19:09:13.450910Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T21:46:09.042Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco IOS",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco IOS"
}
]
}
],
"datePublic": "2018-01-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-399",
"description": "CWE-399",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-01-19T10:57:01",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess"
},
{
"name": "1040240",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1040240"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0088",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IOS",
"version": {
"version_data": [
{
"version_value": "Cisco IOS"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-399"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess"
},
{
"name": "1040240",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1040240"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2018-0088",
"datePublished": "2018-01-18T06:00:00",
"dateReserved": "2017-11-27T00:00:00",
"dateUpdated": "2024-12-02T21:46:09.042Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:industrial_ethernet_4010_series_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D232FD2E-739D-4B22-B23E-394BD0EDFDC2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:ie-4010-16s12p:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"30923A14-84D6-46C5-8E18-9D3D690C3BB2\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:ie-4010-4s24p:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"50526132-968A-4E22-8221-57EE0D3CCBFD\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en uno de los comandos CLI de prueba de diagn\\u00f3stico en Cisco Industrial Ethernet 4010 Series Switches que ejecuten Cisco IOS Software podr\\u00eda permitir que un atacante local autenticado afecte a la estabilidad del dispositivo. Esto podr\\u00eda resultar en una ejecuci\\u00f3n de c\\u00f3digo arbitrario o una condici\\u00f3n de denegaci\\u00f3n de servicio (DoS). El atacante necesita tener credenciales de usuario v\\u00e1lidas a nivel 15 de privilegios. La vulnerabilidad se debe a un comando CLI de prueba de diagn\\u00f3stico que permite que el atacante escriba en la memoria del dispositivo. Un atacante podr\\u00eda explotar esta vulnerabilidad autentic\\u00e1ndose en el dispositivo objetivo y enviando un comando de prueba de diagn\\u00f3stico espec\\u00edfico a la interfaz de l\\u00ednea de comandos. Su explotaci\\u00f3n podr\\u00eda permitir que el atacante sobrescriba las ubicaciones de memoria del sistema, lo que podr\\u00eda causar un impacto negativo en la estabilidad del dispositivo. Cisco Bug IDs: CSCvf71150.\"}]",
"id": "CVE-2018-0088",
"lastModified": "2024-11-21T03:37:29.883",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2018-01-18T06:29:00.377",
"references": "[{\"url\": \"http://www.securitytracker.com/id/1040240\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securitytracker.com/id/1040240\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-399\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-0088\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2018-01-18T06:29:00.377\",\"lastModified\":\"2024-11-21T03:37:29.883\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en uno de los comandos CLI de prueba de diagn\u00f3stico en Cisco Industrial Ethernet 4010 Series Switches que ejecuten Cisco IOS Software podr\u00eda permitir que un atacante local autenticado afecte a la estabilidad del dispositivo. Esto podr\u00eda resultar en una ejecuci\u00f3n de c\u00f3digo arbitrario o una condici\u00f3n de denegaci\u00f3n de servicio (DoS). El atacante necesita tener credenciales de usuario v\u00e1lidas a nivel 15 de privilegios. La vulnerabilidad se debe a un comando CLI de prueba de diagn\u00f3stico que permite que el atacante escriba en la memoria del dispositivo. Un atacante podr\u00eda explotar esta vulnerabilidad autentic\u00e1ndose en el dispositivo objetivo y enviando un comando de prueba de diagn\u00f3stico espec\u00edfico a la interfaz de l\u00ednea de comandos. Su explotaci\u00f3n podr\u00eda permitir que el atacante sobrescriba las ubicaciones de memoria del sistema, lo que podr\u00eda causar un impacto negativo en la estabilidad del dispositivo. Cisco Bug IDs: CSCvf71150.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-399\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:industrial_ethernet_4010_series_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D232FD2E-739D-4B22-B23E-394BD0EDFDC2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:ie-4010-16s12p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30923A14-84D6-46C5-8E18-9D3D690C3BB2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:ie-4010-4s24p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"50526132-968A-4E22-8221-57EE0D3CCBFD\"}]}]}],\"references\":[{\"url\":\"http://www.securitytracker.com/id/1040240\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securitytracker.com/id/1040240\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}, {\"url\": \"http://www.securitytracker.com/id/1040240\", \"name\": \"1040240\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T03:14:16.304Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2018-0088\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-12-02T19:09:13.450910Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-12-02T19:10:17.942Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"Cisco IOS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Cisco IOS\"}]}], \"datePublic\": \"2018-01-18T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"http://www.securitytracker.com/id/1040240\", \"name\": \"1040240\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-399\", \"description\": \"CWE-399\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2018-01-19T10:57:01\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Cisco IOS\"}]}, \"product_name\": \"Cisco IOS\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"name\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess\", \"refsource\": \"CONFIRM\"}, {\"url\": \"http://www.securitytracker.com/id/1040240\", \"name\": \"1040240\", \"refsource\": \"SECTRACK\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-399\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2018-0088\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"psirt@cisco.com\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2018-0088\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-02T21:46:09.042Z\", \"dateReserved\": \"2017-11-27T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2018-01-18T06:00:00\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…