Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:39:08.450Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors", "vendor": "ICS-CERT", "versions": [ { "status": "affected", "version": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3" } ] } ], "datePublic": "2018-06-05T00:00:00", "descriptions": [ { "lang": "en", "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "IMPROPER AUTHENTICATION CWE-287", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-06-05T19:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-06-05T00:00:00", "ID": "CVE-2018-10597", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors", "version": { "version_data": [ { "version_value": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3" } ] } } ] }, "vendor_name": "ICS-CERT" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER AUTHENTICATION CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-10597", "datePublished": "2018-06-05T20:00:00Z", "dateReserved": "2018-05-01T00:00:00", "dateUpdated": "2024-09-16T23:46:22.088Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-10597\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-06-05T20:29:00.827\",\"lastModified\":\"2021-05-10T15:08:11.710\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\\\"write-what-where\\\") from an attacker-chosen device address within the same subnet.\"},{\"lang\":\"es\",\"value\":\"IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que permite que un atacante no autenticado acceda a memoria (\\\"write-what-where\\\") desde una direcci\u00f3n del dispositivo escogida por el atacante en la misma subred.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.4},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":5.5,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4DC680B-B8F8-4FAA-B4C3-D36003BDDCCA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mp2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9178E4C-8965-496C-9FF7-1DF87371DC48\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E42604C2-7CB6-42AC-9272-CFABFC4DC85A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_x2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29626D40-46F7-485F-A700-070424820F16\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"314F12E4-D613-43C4-9B14-5FC9F598AD55\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mp30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E089B9E5-8B28-4DBA-A5D0-B6BBB7D5F3E8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8EE71984-367F-428F-AD0E-D168F76A2002\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mp50:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7216177F-179D-451E-ABC3-C1843AF0D35F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"41A04EC9-FAC7-4C36-8E95-4BDC1E0702FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mp70:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F608D38-1096-41F9-9EB5-854C79068144\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A47C624-AF39-4BE2-9484-54A5E51A784B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_np90:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C202FA49-1CC4-46E6-AA11-3EAB17008AA2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43C2466F-A371-4386-B098-F724D5CD14CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDF21FA3-9650-442F-8E13-281A9975C47B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E9C6A5F3-C845-4561-A451-DC3C966E8D8C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C38B732B-8629-40FE-A333-E69A7F2CFB18\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58F21718-A0DE-419E-B82D-447ADC337E30\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27B8D0E2-316A-45E5-8FC1-AE70F07DB7FA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C337EAF0-41E9-4BF3-8483-6FC74EA93B5A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E73CF245-4519-4F35-A5EE-74981E0BDB9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E119897D-9FB5-461C-8463-EBA3CFC87855\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0CEB056-7422-4E4E-86A5-D58311129788\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6D72DF93-DF02-411D-80BE-85286F553B1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B03E7D9-01DC-492F-BA52-9165E78BE498\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"708EB7F4-9747-4B0C-937D-F1ED07300FAE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_x3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F68AF067-6802-40E7-9D34-03D83D9F3E77\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D7C4F77-6005-4AAA-83CA-CA9F60043A7A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D2A5BBF-C360-4281-AD34-C0941831DA64\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:avalon_fetal\\\\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F3834798-6741-4274-B5C5-0CA2C13A7B12\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:avalon_fetal\\\\/maternal_monitors_fm20:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3A418F05-18B3-405E-A62C-4D9677C297DB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:avalon_fetal\\\\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5634CF44-3593-4D58-8B72-D3DA253530F8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:avalon_fetal\\\\/maternal_monitors_fm30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6C74CF2F-501F-4D18-82C7-4D25D42905E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:avalon_fetal\\\\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55DCC271-9428-4A34-B2C8-DA3CCB74D2DD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:avalon_fetal\\\\/maternal_monitors_fm40:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FD8C562-C918-47DF-AFEB-4CFA53DE3D22\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:philips:avalon_fetal\\\\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AB9A60A-D567-4B7A-A73A-AA566CAD739A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:philips:avalon_fetal\\\\/maternal_monitors_fm50:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D192DA1-C9F4-4666-B0E3-6B0529E3BF3B\"}]}]}],\"references\":[{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.