Summary
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089&Action=Launch | Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/104882 | Broken Link | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | ABB | ABB Panel Builder 800 |
Version: All versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:46:46.044Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01" }, { "name": "104882", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104882" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ABB Panel Builder 800", "vendor": "ABB", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2018-07-17T00:00:00", "descriptions": [ { "lang": "en", "value": "ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "IMPROPER INPUT VALIDATION CWE-20", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-26T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01" }, { "name": "104882", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104882" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-07-17T00:00:00", "ID": "CVE-2018-10616", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ABB Panel Builder 800", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "ABB" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER INPUT VALIDATION CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01" }, { "name": "104882", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104882" }, { "name": "http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch", "refsource": "CONFIRM", "url": "http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-10616", "datePublished": "2018-07-18T15:00:00Z", "dateReserved": "2018-05-01T00:00:00", "dateUpdated": "2024-09-17T00:45:46.975Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-10616\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-07-18T15:29:00.220\",\"lastModified\":\"2019-10-09T23:32:55.650\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.\"},{\"lang\":\"es\",\"value\":\"ABB Panel Builder 800 en todas sus versiones tiene una vulnerabilidad de validaci\u00f3n de entradas incorrecta que podr\u00eda permitir que un atacante inserte y ejecute c\u00f3digo arbitrario en un ordenador en el que se emplea el producto afectado.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":9.3},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:panel_builder_800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85950F28-9F6B-422B-8E2D-94F8DB9C2050\"}]}]}],\"references\":[{\"url\":\"http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/104882\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-198-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.