Summary
ABB Panel Builder 800
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
An attacker could exploit the vulnerability by tricking a user to open a specially crafted file, allowing the attacker to insert and run arbitrary code. This vulnerability requires user interaction, and the exploit is only triggered when a local user runs the affected product and loads the specially crafted file.
Critical infrastructure sectors
Chemical, Critical Manufacturing, Energy, Dams, Water and Wastewater, and Food and Agriculture
Countries/areas deployed
Worldwide
Company headquarters location
Switzerland
Recommended Practices
NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. High skill level is needed to exploit.
{ "document": { "acknowledgments": [ { "names": [ "Michael DePlante" ], "organization": "Leahy Center", "summary": "reporting this vulnerability to ABB" }, { "names": [ "Michael Flanders" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting this vulnerability to ABB" }, { "organization": "ABB", "summary": "reporting it to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "An attacker could exploit the vulnerability by tricking a user to open a specially crafted file, allowing the attacker to insert and run arbitrary code. This vulnerability requires user interaction, and the exploit is only triggered when a local user runs the affected product and loads the specially crafted file.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Energy, Dams, Water and Wastewater, and Food and Agriculture", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. High skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-198-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-198-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-198-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-198-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ABB Panel Builder 800", "tracking": { "current_release_date": "2018-07-17T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-198-01", "initial_release_date": "2018-07-17T00:00:00.000000Z", "revision_history": [ { "date": "2018-07-17T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-198-01 ABB Panel Builder 800" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "Panel Builder 800: all versions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Panel Builder 800" } ], "category": "vendor", "name": "ABB" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-10616", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An improper input validation vulnerability has been identified, which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.CVE-2018-10616 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-10616" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Conduct or reinforce cybersecurity awareness training for users of Panel Builder 800: Describing general cybersecurity best practice recommendations for industrial control systems, Informing that it is possible to infect Panel Builder files with malware, Describing the importance of being careful with files that are received unexpectedly and/or from unexpected sources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully inspecting any files transferred between computers, including scanning them with up-to-date antivirus software, so that only the legitimate files are being transferred.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "User account management, appropriate authentication and permission management using the principle of least privilege.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Please see the following cybersecurity advisory on the ABB website for more information:", "product_ids": [ "CSAFPID-0001" ], "url": "http://search-ext.abb.com/library/Download.aspx?DocumentID=3BSE092089\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.