cve-2018-11229
Vulnerability from cvelistv5
Published
2018-06-08 01:00
Modified
2024-08-05 08:01
Severity ?
EPSS score ?
Summary
Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://www.securityfocus.com/bid/105051 | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01 | Third Party Advisory, US Government Resource | |
cve@mitre.org | https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T08:01:52.667Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "105051", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/105051" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-07T00:00:00", "descriptions": [ { "lang": "en", "value": "Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-08-14T09:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "105051", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/105051" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-11229", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "105051", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105051" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01" }, { "name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet", "refsource": "CONFIRM", "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-11229", "datePublished": "2018-06-08T01:00:00", "dateReserved": "2018-05-17T00:00:00", "dateUpdated": "2024-08-05T08:01:52.667Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-11229\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2018-06-08T01:29:00.997\",\"lastModified\":\"2019-05-13T18:31:15.047\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP).\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC y TSW-560-NC en versiones anteriores a la 2.001.0037.001 permiten la ejecuci\u00f3n remota de c\u00f3digo sin autenticar mediante una inyecci\u00f3n de comandos en CTP (Crestron Toolbox Protocol).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":7.5},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:crestron_toolbox_protocol_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.001.0037.001\",\"matchCriteriaId\":\"990FAF8F-A8B1-46B9-9C75-0ECF3A636B20\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dmc-str:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88961DC9-941C-480F-90EB-C572D0C0DD79\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-1060:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"199FB4DB-871C-422D-9082-C0C7F1E241CF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-1060-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB8F6CD2-49B9-489E-9413-881D3D0DE791\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-560:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B107D415-5148-4323-A71E-AD694BE2CE16\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-560-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E44817F9-2CC7-4794-A0C0-8A9718AFA136\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-760:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BCDAF5B8-C9B3-49F9-A558-EFC89C918806\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-760-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD7F2F4A-7697-445A-A1B0-A66BA5DEC70A\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105051\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.