CVE-2018-14790 (GCVE-0-2018-14790)
Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-17 03:32
VLAI?
Summary
Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.
Severity ?
No CVSS data available.
CWE
- CWE-126 - BUFFER OVER-READ CWE-126
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace |
Affected:
v3.3 v7.3.4.1a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.951Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105408",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105408"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "v3.3 v7.3.4.1a"
}
]
}
],
"datePublic": "2018-09-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-126",
"description": "BUFFER OVER-READ CWE-126",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-02T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105408",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105408"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-27T00:00:00",
"ID": "CVE-2018-14790",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
"version": {
"version_data": [
{
"version_value": "v3.3 v7.3.4.1a"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER OVER-READ CWE-126"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105408",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105408"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14790",
"datePublished": "2018-10-01T13:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-17T03:32:22.942Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fujielectric:frenic_loader_3.3_firmware:7.3.4.1a:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"047DAA36-D21F-4563-8C57-9829048BBAA3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-ace:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E9D4C166-2E13-45FF-A2FD-410D36DE3DAF\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-eco:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"ECB1557C-2F2E-41BF-B288-02694D7170CB\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-mega:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B895CAB3-FE3A-4B4C-BC57-764D153461DF\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-mini\\\\(c1\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E4E0156F-6435-4DE6-97E0-E7E9D85621DD\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-mini\\\\(c2\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"858682FA-3073-410B-9BE7-FFA77D9753C0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fujielectric:frenic-multi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FA31A696-5425-47CB-84EB-527FEEA86CC9\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.\"}, {\"lang\": \"es\", \"value\": \"Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a de FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA y FRENIC-Ace. Una vulnerabilidad de sobrelectura de b\\u00fafer podr\\u00eda permitir la ejecuci\\u00f3n remota de c\\u00f3digo en el dispositivo.\"}]",
"id": "CVE-2018-14790",
"lastModified": "2024-11-21T03:49:47.973",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2018-10-01T13:29:00.440",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/105408\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/105408\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-126\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-14790\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-10-01T13:29:00.440\",\"lastModified\":\"2024-11-21T03:49:47.973\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.\"},{\"lang\":\"es\",\"value\":\"Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a de FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA y FRENIC-Ace. Una vulnerabilidad de sobrelectura de b\u00fafer podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo en el dispositivo.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-126\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujielectric:frenic_loader_3.3_firmware:7.3.4.1a:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"047DAA36-D21F-4563-8C57-9829048BBAA3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-ace:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E9D4C166-2E13-45FF-A2FD-410D36DE3DAF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-eco:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ECB1557C-2F2E-41BF-B288-02694D7170CB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-mega:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B895CAB3-FE3A-4B4C-BC57-764D153461DF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-mini\\\\(c1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4E0156F-6435-4DE6-97E0-E7E9D85621DD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-mini\\\\(c2\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"858682FA-3073-410B-9BE7-FFA77D9753C0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujielectric:frenic-multi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA31A696-5425-47CB-84EB-527FEEA86CC9\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105408\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/105408\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…