CVE-2019-0130 (GCVE-0-2019-0130)
Vulnerability from cvelistv5 – Published: 2019-06-13 15:36 – Updated: 2024-08-04 17:44
VLAI?
Summary
Reflected XSS in web interface for Intel(R) Accelerated Storage Manager in Intel(R) RSTe before version 5.5.0.2015 may allow an unauthenticated user to potentially enable denial of service via network access.
Severity ?
No CVSS data available.
CWE
- Escalation of Privilege, Denial of Service
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) Accelerated Storage Manager in Intel® Rapid Storage Technology Enterprise Advisory |
Affected:
Version before 5.5.0.2015
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:44:14.466Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html"
},
{
"name": "108775",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108775"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-27843"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) Accelerated Storage Manager in Intel\u00ae Rapid Storage Technology Enterprise Advisory",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Version before 5.5.0.2015"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Reflected XSS in web interface for Intel(R) Accelerated Storage Manager in Intel(R) RSTe before version 5.5.0.2015 may allow an unauthenticated user to potentially enable denial of service via network access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Escalation of Privilege, Denial of Service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-24T15:33:58",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html"
},
{
"name": "108775",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108775"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-27843"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2019-0130",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) Accelerated Storage Manager in Intel\u00ae Rapid Storage Technology Enterprise Advisory",
"version": {
"version_data": [
{
"version_value": "Version before 5.5.0.2015"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Reflected XSS in web interface for Intel(R) Accelerated Storage Manager in Intel(R) RSTe before version 5.5.0.2015 may allow an unauthenticated user to potentially enable denial of service via network access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Escalation of Privilege, Denial of Service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html",
"refsource": "CONFIRM",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html"
},
{
"name": "108775",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108775"
},
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-27843",
"refsource": "CONFIRM",
"url": "https://support.lenovo.com/us/en/product_security/LEN-27843"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2019-0130",
"datePublished": "2019-06-13T15:36:25",
"dateReserved": "2018-11-13T00:00:00",
"dateUpdated": "2024-08-04T17:44:14.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:rapid_storage_technology_enterprise:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.5.0.2015\", \"matchCriteriaId\": \"901DA51D-7BEA-4DD6-9ADF-B776D2218C47\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:lenovo:thinkstation_p520_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0BA83987-B0E4-4BF8-8379-43B90420AAFD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:lenovo:thinkstation_p520:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6840BC60-44C3-4EA8-96D3-E93796C15310\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:lenovo:thinkstation_p520c_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E6E5525D-2EA6-4226-A6A3-5C1E442720E1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:lenovo:thinkstation_p520c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0431D83D-1AC8-4EDE-8568-8695F8E68C35\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:lenovo:thinkstation_p720_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0530CA83-60EA-422B-B0D1-6193336E0AD3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:lenovo:thinkstation_p720:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A77DF681-F12F-4643-B5E1-1BEDE613E343\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:lenovo:thinkstation_p920_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FB0B747D-09A0-4FBE-9984-6FDFD38CAADE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:lenovo:thinkstation_p920:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D47FCAA7-B33F-4F00-85BA-AA8ED4790572\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Reflected XSS in web interface for Intel(R) Accelerated Storage Manager in Intel(R) RSTe before version 5.5.0.2015 may allow an unauthenticated user to potentially enable denial of service via network access.\"}, {\"lang\": \"es\", \"value\": \"Un XSS reflejado en la interfaz web para Accelerated Storage Manager de Intel\\u00ae en RSTe de Intel\\u00ae anterior a versi\\u00f3n 5.5.0.2015, puede permitir que un usuario no autenticado pueda habilitar potencialmente la denegaci\\u00f3n de servicio por medio de un acceso a la red.\"}]",
"id": "CVE-2019-0130",
"lastModified": "2024-11-21T04:16:17.970",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:N/A:H\", \"baseScore\": 7.4, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 4.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:N/A:P\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2019-06-13T16:29:00.403",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/108775\", \"source\": \"secure@intel.com\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://support.lenovo.com/us/en/product_security/LEN-27843\", \"source\": \"secure@intel.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/108775\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://support.lenovo.com/us/en/product_security/LEN-27843\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-0130\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2019-06-13T16:29:00.403\",\"lastModified\":\"2024-11-21T04:16:17.970\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Reflected XSS in web interface for Intel(R) Accelerated Storage Manager in Intel(R) RSTe before version 5.5.0.2015 may allow an unauthenticated user to potentially enable denial of service via network access.\"},{\"lang\":\"es\",\"value\":\"Un XSS reflejado en la interfaz web para Accelerated Storage Manager de Intel\u00ae en RSTe de Intel\u00ae anterior a versi\u00f3n 5.5.0.2015, puede permitir que un usuario no autenticado pueda habilitar potencialmente la denegaci\u00f3n de servicio por medio de un acceso a la red.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:N/A:H\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":4.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:P\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:rapid_storage_technology_enterprise:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0.2015\",\"matchCriteriaId\":\"901DA51D-7BEA-4DD6-9ADF-B776D2218C47\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkstation_p520_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BA83987-B0E4-4BF8-8379-43B90420AAFD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkstation_p520:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6840BC60-44C3-4EA8-96D3-E93796C15310\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkstation_p520c_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6E5525D-2EA6-4226-A6A3-5C1E442720E1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkstation_p520c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0431D83D-1AC8-4EDE-8568-8695F8E68C35\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkstation_p720_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0530CA83-60EA-422B-B0D1-6193336E0AD3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkstation_p720:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A77DF681-F12F-4643-B5E1-1BEDE613E343\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:lenovo:thinkstation_p920_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB0B747D-09A0-4FBE-9984-6FDFD38CAADE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:lenovo:thinkstation_p920:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D47FCAA7-B33F-4F00-85BA-AA8ED4790572\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108775\",\"source\":\"secure@intel.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.lenovo.com/us/en/product_security/LEN-27843\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/108775\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.lenovo.com/us/en/product_security/LEN-27843\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00226.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…