cve-2019-10928
Vulnerability from cvelistv5
Published
2019-08-13 18:55
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
Impacted products
Siemens AGSCALANCE SC-600
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.097Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE SC-600",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "V2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T13:18:04",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10928",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE SC-600",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10928",
    "datePublished": "2019-08-13T18:55:57",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.097Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-10928\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-08-13T19:15:14.767\",\"lastModified\":\"2020-10-02T14:09:24.937\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SCALANCE SC-600 (V2.0). Un atacante autenticado con acceso al puerto 22 / tcp, as\u00ed como acceso f\u00edsico a un dispositivo afectado, puede activar el dispositivo para permitir la ejecuci\u00f3n de comandos arbitrarios. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante autenticado con acceso f\u00edsico al dispositivo afectado. No se requiere interacci\u00f3n del usuario para explotar esta vulnerabilidad. La vulnerabilidad afecta la confidencialidad, integridad y disponibilidad del dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.6,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.7,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-703\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_sc-600_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A39EC3B9-29E8-4DF3-91FD-42FE0A4AFC3D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"725C671B-D7A0-48CF-8A31-5F9C4173F1DD\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.