CVE-2019-18340 (GCVE-0-2019-18340)

Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:54
VLAI?
Summary
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), Control Center Server (CCS) (All versions >= V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store user and device passwords by applying weak cryptography. A local attacker could exploit this vulnerability to extract the passwords from the user database and/or the device configuration files to conduct further attacks.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:54:14.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Control Center Server (CCS)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Control Center Server (CCS)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V1.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SiNVR/SiVMS Video Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SiNVR/SiVMS Video Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\nuser and device passwords by applying weak cryptography.\n\nA local attacker could exploit this vulnerability to extract\nthe passwords from the user database and/or the device configuration files\nto conduct further attacks."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:F/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T09:56:14.606Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-18340",
    "datePublished": "2019-12-12T19:08:49",
    "dateReserved": "2019-10-23T00:00:00",
    "dateUpdated": "2024-08-05T01:54:14.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"16668E9A-2D0A-425E-87F4-18CFC50551D3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0F21BB6D-BFE0-4B69-97F2-1A871A390B1E\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\\nuser and device passwords by applying weak cryptography.\\n\\nA local attacker could exploit this vulnerability to extract\\nthe passwords from the user database and/or the device configuration files\\nto conduct further attacks.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en Central Control Server (CCS) (Todas las versiones anteriores a V1.5.0), Control Center Server (CCS) (Todas las versiones anteriores o iguales a V1.5.0), SiNVR/SiVMS Video Server (Todas las versiones anteriores a V5.0.0). Tanto el servidor de video SiVMS/SiNVR 3 como el Central Control Server (CCS) almacenan las contrase\\u00f1as de usuarios y dispositivos mediante una aplicaci\\u00f3n de criptograf\\u00eda d\\u00e9bil. Un atacante local podr\\u00eda explotar esta vulnerabilidad para extraer las contrase\\u00f1as de la base de datos del usuario y/o los archivos de configuraci\\u00f3n del dispositivo para conducir nuevos ataques adicionales.\"}]",
      "id": "CVE-2019-18340",
      "lastModified": "2024-11-21T04:33:04.860",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 2.1, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-12-12T19:15:20.560",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-327\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-327\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-18340\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-12-12T19:15:20.560\",\"lastModified\":\"2024-11-21T04:33:04.860\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\\nuser and device passwords by applying weak cryptography.\\n\\nA local attacker could exploit this vulnerability to extract\\nthe passwords from the user database and/or the device configuration files\\nto conduct further attacks.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Central Control Server (CCS) (Todas las versiones anteriores a V1.5.0), Control Center Server (CCS) (Todas las versiones anteriores o iguales a V1.5.0), SiNVR/SiVMS Video Server (Todas las versiones anteriores a V5.0.0). Tanto el servidor de video SiVMS/SiNVR 3 como el Central Control Server (CCS) almacenan las contrase\u00f1as de usuarios y dispositivos mediante una aplicaci\u00f3n de criptograf\u00eda d\u00e9bil. Un atacante local podr\u00eda explotar esta vulnerabilidad para extraer las contrase\u00f1as de la base de datos del usuario y/o los archivos de configuraci\u00f3n del dispositivo para conducir nuevos ataques adicionales.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"16668E9A-2D0A-425E-87F4-18CFC50551D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F21BB6D-BFE0-4B69-97F2-1A871A390B1E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.