CVE-2019-2430 (GCVE-0-2019-2430)

Vulnerability from cvelistv5 – Published: 2019-01-16 19:00 – Updated: 2024-10-02 16:19
VLAI?
Summary
Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).
Severity ?
No CVSS data available.
CWE
  • Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data.
Assigner
References
Impacted products
Vendor Product Version
Oracle Corporation Argus Safety Affected: 8.1
Affected: 8.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T18:49:47.799Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html"
          },
          {
            "name": "106599",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106599"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-2430",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T14:02:56.652086Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T16:19:20.704Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Argus Safety",
          "vendor": "Oracle Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "8.1"
            },
            {
              "status": "affected",
              "version": "8.2"
            }
          ]
        }
      ],
      "datePublic": "2019-01-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety.  Successful attacks of this vulnerability can result in  unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-17T10:57:01",
        "orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
        "shortName": "oracle"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html"
        },
        {
          "name": "106599",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106599"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert_us@oracle.com",
          "ID": "CVE-2019-2430",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Argus Safety",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "8.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Oracle Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety.  Successful attacks of this vulnerability can result in  unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html",
              "refsource": "CONFIRM",
              "url": "http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html"
            },
            {
              "name": "106599",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106599"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
    "assignerShortName": "oracle",
    "cveId": "CVE-2019-2430",
    "datePublished": "2019-01-16T19:00:00",
    "dateReserved": "2018-12-14T00:00:00",
    "dateUpdated": "2024-10-02T16:19:20.704Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:argus_safety:8.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"51B5A759-6F8C-4867-874C-9286F5D98BB9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:argus_safety:8.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"72C7BCF9-A70F-4B76-89E4-5B1AED720930\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad en el componente Oracle Argus Safety de Oracle Health Sciences Applications (subcomponente: Console). Las versiones compatibles que se han visto afectadas son la 8.1 y la 8.2. Esta vulnerabilidad f\\u00e1cilmente explotable permite que un atacante con bajos privilegios con acceso en red v\\u00eda HTTP comprometa la seguridad de Oracle Argus Safety. Los ataques exitosos a esta vulnerabilidad pueden resultar en un acceso no autorizado a datos de suma importancia o un acceso completo a todos los datos accesibles de Oracle Argus Safety. CVSS 3.0 Base Score 6.5 (impactos en la confidencialidad). Vector CVSS: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}]",
      "id": "CVE-2019-2430",
      "lastModified": "2024-11-21T04:40:51.443",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-01-16T19:30:31.827",
      "references": "[{\"url\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"source\": \"secalert_us@oracle.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/106599\", \"source\": \"secalert_us@oracle.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/106599\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
      "sourceIdentifier": "secalert_us@oracle.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-2430\",\"sourceIdentifier\":\"secalert_us@oracle.com\",\"published\":\"2019-01-16T19:30:31.827\",\"lastModified\":\"2024-11-21T04:40:51.443\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad en el componente Oracle Argus Safety de Oracle Health Sciences Applications (subcomponente: Console). Las versiones compatibles que se han visto afectadas son la 8.1 y la 8.2. Esta vulnerabilidad f\u00e1cilmente explotable permite que un atacante con bajos privilegios con acceso en red v\u00eda HTTP comprometa la seguridad de Oracle Argus Safety. Los ataques exitosos a esta vulnerabilidad pueden resultar en un acceso no autorizado a datos de suma importancia o un acceso completo a todos los datos accesibles de Oracle Argus Safety. CVSS 3.0 Base Score 6.5 (impactos en la confidencialidad). Vector CVSS: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:argus_safety:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"51B5A759-6F8C-4867-874C-9286F5D98BB9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:argus_safety:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"72C7BCF9-A70F-4B76-89E4-5B1AED720930\"}]}]}],\"references\":[{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/106599\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/106599\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}, {\"url\": \"http://www.securityfocus.com/bid/106599\", \"name\": \"106599\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T18:49:47.799Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-2430\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-02T14:02:56.652086Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-02T14:03:54.516Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Oracle Corporation\", \"product\": \"Argus Safety\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.1\"}, {\"status\": \"affected\", \"version\": \"8.2\"}]}], \"datePublic\": \"2019-01-15T00:00:00\", \"references\": [{\"url\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"http://www.securityfocus.com/bid/106599\", \"name\": \"106599\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety.  Successful attacks of this vulnerability can result in  unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data.\"}]}], \"providerMetadata\": {\"orgId\": \"43595867-4340-4103-b7a2-9a5208d29a85\", \"shortName\": \"oracle\", \"dateUpdated\": \"2019-01-17T10:57:01\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"8.1\", \"version_affected\": \"=\"}, {\"version_value\": \"8.2\", \"version_affected\": \"=\"}]}, \"product_name\": \"Argus Safety\"}]}, \"vendor_name\": \"Oracle Corporation\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"name\": \"http://www.oracle.com/technetwork/security-advisory/cpujan2019-5072801.html\", \"refsource\": \"CONFIRM\"}, {\"url\": \"http://www.securityfocus.com/bid/106599\", \"name\": \"106599\", \"refsource\": \"BID\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety.  Successful attacks of this vulnerability can result in  unauthorized access to critical data or complete access to all Oracle Argus Safety accessible data.\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2019-2430\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"secalert_us@oracle.com\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2019-2430\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-02T16:19:20.704Z\", \"dateReserved\": \"2018-12-14T00:00:00\", \"assignerOrgId\": \"43595867-4340-4103-b7a2-9a5208d29a85\", \"datePublished\": \"2019-01-16T19:00:00\", \"assignerShortName\": \"oracle\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…