cve-2019-3951
Vulnerability from cvelistv5
Published
2019-12-12 20:32
Modified
2024-08-04 19:26
Severity ?
Summary
Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages.
References
Impacted products
n/aAdvantech WebAccess/SCADA
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:26:27.479Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-52"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Advantech WebAccess/SCADA",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "8.4.2."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack buffer overflow to code execution.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-12-12T20:32:10",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-52"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2019-3951",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Advantech WebAccess/SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "8.4.2."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack buffer overflow to code execution."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2019-52",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-52"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2019-3951",
    "datePublished": "2019-12-12T20:32:10",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-08-04T19:26:27.479Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-3951\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2019-12-12T21:15:12.120\",\"lastModified\":\"2019-12-18T19:56:48.257\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages.\"},{\"lang\":\"es\",\"value\":\"Advantech WebAccess versiones anteriores a 8.4.3, permite a atacantes remotos no autenticados ejecutar c\u00f3digo arbitrario o causar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria) debido a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria al manejar mensajes IOCTL 70533 RPC.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":7.5},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"vulnreport@tenable.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:webaccess:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.4.3\",\"matchCriteriaId\":\"B0196093-D216-4959-AF30-5EE649EE2D6C\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2019-52\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.