CVE-2019-6835 (GCVE-0-2019-6835)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:13 – Updated: 2024-08-04 20:31
VLAI?
Summary
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Cross-Site Scripting (XSS) CWE-79
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | U.motion Server |
Affected:
MEG6501-0001 - U.motion KNX server
Affected: MEG6501-0002 - U.motion KNX Server Plus Affected: MEG6260-0410 - U.motion KNX Server Plus Affected: Touch 10 Affected: MEG6260-0415 - U.motion KNX Server Plus Affected: Touch 15 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "U.motion Server",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "MEG6501-0001 - U.motion KNX server"
},
{
"status": "affected",
"version": "MEG6501-0002 - U.motion KNX Server Plus"
},
{
"status": "affected",
"version": "MEG6260-0410 - U.motion KNX Server Plus"
},
{
"status": "affected",
"version": "Touch 10"
},
{
"status": "affected",
"version": "MEG6260-0415 - U.motion KNX Server Plus"
},
{
"status": "affected",
"version": "Touch 15"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "\u00a0Cross-Site Scripting (XSS) CWE-79\u00a0",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:13:26",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6835",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "U.motion Server",
"version": {
"version_data": [
{
"version_value": "MEG6501-0001 - U.motion KNX server"
},
{
"version_value": "MEG6501-0002 - U.motion KNX Server Plus"
},
{
"version_value": "MEG6260-0410 - U.motion KNX Server Plus"
},
{
"version_value": "Touch 10"
},
{
"version_value": "MEG6260-0415 - U.motion KNX Server Plus"
},
{
"version_value": "Touch 15"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "\u00a0Cross-Site Scripting (XSS) CWE-79\u00a0"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6835",
"datePublished": "2019-09-17T19:13:26",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6501-0001_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.7\", \"matchCriteriaId\": \"716CA99C-BB90-422B-9EAD-A066D48DE1E8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6501-0001:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DB83620B-3DE0-405A-92F7-99E1B2150E75\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6501-0002_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.7\", \"matchCriteriaId\": \"0D2468D0-D50D-4843-8620-CAD0F40E9329\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6501-0002:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC12A2AA-C006-4606-981A-FE54C1EA3B3F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6260-0410_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.7\", \"matchCriteriaId\": \"DB404224-29BF-4440-963C-0734A51CE6D1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6260-0410:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0936523A-B9CB-451E-BF5E-9E7020DA96A2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6260-0415_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.7\", \"matchCriteriaId\": \"7C17C8F6-8C97-43D5-8ECE-7D9204F3C75D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:schneider-electric:meg6260-0415:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F93C8296-5845-498A-964A-D650F45B27B6\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) CWE-79 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), que podr\\u00eda permitir a un atacante inyectar script del lado del cliente cuando un usuario visita una p\\u00e1gina web.\"}]",
"id": "CVE-2019-6835",
"lastModified": "2024-11-21T04:47:14.870",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2019-09-17T20:15:12.530",
"references": "[{\"url\": \"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6835\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-09-17T20:15:12.530\",\"lastModified\":\"2024-11-21T04:47:14.870\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) CWE-79 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), que podr\u00eda permitir a un atacante inyectar script del lado del cliente cuando un usuario visita una p\u00e1gina web.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6501-0001_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.7\",\"matchCriteriaId\":\"716CA99C-BB90-422B-9EAD-A066D48DE1E8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6501-0001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB83620B-3DE0-405A-92F7-99E1B2150E75\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6501-0002_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.7\",\"matchCriteriaId\":\"0D2468D0-D50D-4843-8620-CAD0F40E9329\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6501-0002:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC12A2AA-C006-4606-981A-FE54C1EA3B3F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6260-0410_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.7\",\"matchCriteriaId\":\"DB404224-29BF-4440-963C-0734A51CE6D1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6260-0410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0936523A-B9CB-451E-BF5E-9E7020DA96A2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6260-0415_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.7\",\"matchCriteriaId\":\"7C17C8F6-8C97-43D5-8ECE-7D9204F3C75D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:schneider-electric:meg6260-0415:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F93C8296-5845-498A-964A-D650F45B27B6\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…