Summary
Cross Site Scripting vulnerability in Micro Focus Service Manager product. Affecting versions 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. The vulnerability could be exploited to allow remote attackers to inject arbitrary web script or HTML.
Severity ?
No CVSS data available.
CWE
- Cross Site Scripting.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Service Manager. |
Affected:
9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:41:59.796Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://softwaresupport.softwaregrp.com/doc/KM03640285"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Service Manager.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross Site Scripting vulnerability in Micro Focus Service Manager product. Affecting versions 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. The vulnerability could be exploited to allow remote attackers to inject arbitrary web script or HTML."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross Site Scripting.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:39",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://softwaresupport.softwaregrp.com/doc/KM03640285"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2020-11845",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Service Manager.",
"version": {
"version_data": [
{
"version_value": "9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross Site Scripting vulnerability in Micro Focus Service Manager product. Affecting versions 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. The vulnerability could be exploited to allow remote attackers to inject arbitrary web script or HTML."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross Site Scripting."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://softwaresupport.softwaregrp.com/doc/KM03640285",
"refsource": "MISC",
"url": "https://softwaresupport.softwaregrp.com/doc/KM03640285"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2020-11845",
"datePublished": "2020-05-19T14:05:21",
"dateReserved": "2020-04-16T00:00:00",
"dateUpdated": "2024-08-04T11:41:59.796Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:microfocus:service_manager:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.50\", \"versionEndIncluding\": \"9.63\", \"matchCriteriaId\": \"2F2372DD-AABE-43DF-8873-59CECFEA88CF\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Cross Site Scripting vulnerability in Micro Focus Service Manager product. Affecting versions 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. The vulnerability could be exploited to allow remote attackers to inject arbitrary web script or HTML.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de tipo Cross Site Scripting en el producto Micro Focus Service Manager. Afectando las versiones 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. La vulnerabilidad podr\\u00eda ser explotada para permitir a atacantes remotos inyectar script web o HTML arbitrario.\"}]",
"id": "CVE-2020-11845",
"lastModified": "2024-11-21T04:58:44.680",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-05-19T15:15:11.340",
"references": "[{\"url\": \"https://softwaresupport.softwaregrp.com/doc/KM03640285\", \"source\": \"security@opentext.com\"}, {\"url\": \"https://softwaresupport.softwaregrp.com/doc/KM03640285\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "security@opentext.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-11845\",\"sourceIdentifier\":\"security@opentext.com\",\"published\":\"2020-05-19T15:15:11.340\",\"lastModified\":\"2024-11-21T04:58:44.680\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross Site Scripting vulnerability in Micro Focus Service Manager product. Affecting versions 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. The vulnerability could be exploited to allow remote attackers to inject arbitrary web script or HTML.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de tipo Cross Site Scripting en el producto Micro Focus Service Manager. Afectando las versiones 9.50, 9.51, 9.52, 9.60, 9.61, 9.62, 9.63. La vulnerabilidad podr\u00eda ser explotada para permitir a atacantes remotos inyectar script web o HTML arbitrario.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:service_manager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.50\",\"versionEndIncluding\":\"9.63\",\"matchCriteriaId\":\"2F2372DD-AABE-43DF-8873-59CECFEA88CF\"}]}]}],\"references\":[{\"url\":\"https://softwaresupport.softwaregrp.com/doc/KM03640285\",\"source\":\"security@opentext.com\"},{\"url\":\"https://softwaresupport.softwaregrp.com/doc/KM03640285\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…