Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-14396 (GCVE-0-2020-14396)
Vulnerability from cvelistv5 – Published: 2020-06-17 15:13 – Updated: 2024-08-04 12:46- n/a
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.415Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"name": "USN-4434-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU",
"x_transferred"
],
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-14T13:06:41",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"name": "USN-4434-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU"
],
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-14396",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13",
"refsource": "MISC",
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"name": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553",
"refsource": "MISC",
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"name": "USN-4434-1",
"refsource": "UBUNTU",
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-14396",
"datePublished": "2020-06-17T15:13:40",
"dateReserved": "2020-06-17T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.415Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:libvnc_project:libvncserver:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"0.9.12\", \"matchCriteriaId\": \"A03A7282-D445-4E26-98A0-6A1597838D35\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:lts:*:*:*\", \"matchCriteriaId\": \"B5A6F2F3-4894-4392-8296-3B8DD2679084\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*\", \"matchCriteriaId\": \"7A5301BF-1402-4BE0-A0F8-69FBE79BC6D6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*\", \"matchCriteriaId\": \"F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*\", \"matchCriteriaId\": \"23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:18.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"07C312A0-CD2C-4B9C-B064-6409B25C278F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*\", \"matchCriteriaId\": \"902B8056-9E37-443B-8905-8AA93E2447FB\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C11E6FB0-C8C0-4527-9AA0-CB9B316F8F43\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DEECE5FC-CACF-4496-A3E7-164736409252\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc1500_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"3A664216-EEA0-423F-8E11-59C746FDEEFE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc1500:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9596C8CD-B03F-4E9D-82AB-0986FDD1B47C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc1500_pro_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"CD78291E-48D8-4718-AE14-BDF93BD557D7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc1500_pro:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5BB898D3-07A3-42A1-8F1B-53C3B005982D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc1900_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"AD1209DE-2724-493D-8276-1BE959BFE6BF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc1900:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6A9143A6-A93A-45CA-8A1F-6EE30647B54A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc1900_pro_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"92F7FC17-F19F-4BD6-9704-49B67D22B532\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc1900_pro:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3D34BD13-4E71-48A2-851D-AE7CE2A03C28\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc2200_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"FE4A6F13-385B-4A13-B8D8-3BBC4E9D5B67\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc2200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3E63E423-7450-4043-B33B-3FFF5BBE1CB2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_itc2200_pro_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0.0.0\", \"versionEndExcluding\": \"3.2.1.0\", \"matchCriteriaId\": \"71A51CA4-1A62-47BC-99A3-4DC9F3986FF5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_itc2200_pro:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CD278558-AB0E-4FC1-9E5B-6B57D29CB86A\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.\"}, {\"lang\": \"es\", \"value\": \"Se detect\\u00f3 un problema en LibVNCServer versiones anteriores a 0.9.13. La biblioteca libvncclient/tls_openssl.c presenta una desreferencia del puntero NULL\"}]",
"id": "CVE-2020-14396",
"lastModified": "2024-11-21T05:03:10.293",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-06-17T16:15:11.697",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553\", \"source\": \"cve@mitre.org\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13\", \"source\": \"cve@mitre.org\", \"tags\": [\"Release Notes\", \"Third Party Advisory\"]}, {\"url\": \"https://usn.ubuntu.com/4434-1/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Release Notes\", \"Third Party Advisory\"]}, {\"url\": \"https://usn.ubuntu.com/4434-1/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-476\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-14396\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-06-17T16:15:11.697\",\"lastModified\":\"2024-11-21T05:03:10.293\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en LibVNCServer versiones anteriores a 0.9.13. La biblioteca libvncclient/tls_openssl.c presenta una desreferencia del puntero NULL\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:libvnc_project:libvncserver:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"0.9.12\",\"matchCriteriaId\":\"A03A7282-D445-4E26-98A0-6A1597838D35\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"B5A6F2F3-4894-4392-8296-3B8DD2679084\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*\",\"matchCriteriaId\":\"7A5301BF-1402-4BE0-A0F8-69FBE79BC6D6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:18.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07C312A0-CD2C-4B9C-B064-6409B25C278F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"902B8056-9E37-443B-8905-8AA93E2447FB\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C11E6FB0-C8C0-4527-9AA0-CB9B316F8F43\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DEECE5FC-CACF-4496-A3E7-164736409252\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc1500_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"3A664216-EEA0-423F-8E11-59C746FDEEFE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc1500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9596C8CD-B03F-4E9D-82AB-0986FDD1B47C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc1500_pro_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"CD78291E-48D8-4718-AE14-BDF93BD557D7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc1500_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5BB898D3-07A3-42A1-8F1B-53C3B005982D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc1900_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"AD1209DE-2724-493D-8276-1BE959BFE6BF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc1900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A9143A6-A93A-45CA-8A1F-6EE30647B54A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc1900_pro_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"92F7FC17-F19F-4BD6-9704-49B67D22B532\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc1900_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D34BD13-4E71-48A2-851D-AE7CE2A03C28\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc2200_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"FE4A6F13-385B-4A13-B8D8-3BBC4E9D5B67\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc2200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E63E423-7450-4043-B33B-3FFF5BBE1CB2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itc2200_pro_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.0.0\",\"versionEndExcluding\":\"3.2.1.0\",\"matchCriteriaId\":\"71A51CA4-1A62-47BC-99A3-4DC9F3986FF5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itc2200_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD278558-AB0E-4FC1-9E5B-6B57D29CB86A\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13\",\"source\":\"cve@mitre.org\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://usn.ubuntu.com/4434-1/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://usn.ubuntu.com/4434-1/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
ICSA-21-350-12
Vulnerability from csaf_cisa - Published: 2021-12-14 00:00 - Updated: 2025-05-06 06:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Multiple LibVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-390195.json"
},
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-390195.txt"
},
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-350-12 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-350-12.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-350-12 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-350-12"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC ITC",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-350-12",
"initial_release_date": "2021-12-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-12-14T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC1500 V3",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1500 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC1500 V3 PRO",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1500 V3 PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC1900 V3",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1900 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC1900 V3 PRO",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1900 V3 PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC2200 V3",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC2200 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.2.1.0",
"product": {
"name": "SIMATIC ITC2200 V3 PRO",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC2200 V3 PRO"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-18922",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2017-18922 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2017-18922.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2017-18922"
},
{
"cve": "CVE-2018-20019",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2018-20019 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20019.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2018-20019"
},
{
"cve": "CVE-2018-20748",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c. The fix for CVE-2018-20019 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2018-20748 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20748.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2018-20748"
},
{
"cve": "CVE-2018-20749",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2018-20749 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20749.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2018-20749"
},
{
"cve": "CVE-2018-20750",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC through 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2018-20750 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20750.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2018-20750"
},
{
"cve": "CVE-2018-21247",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. There is an information leak (of uninitialized memory contents) in the libvncclient/rfbproto.c ConnectToRFBRepeater function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2018-21247 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-21247.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2018-21247"
},
{
"cve": "CVE-2019-15681",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2019-15681 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15681.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2019-15681"
},
{
"cve": "CVE-2019-15690",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in libvncserver. An integer overflow within the HandleCursorShape() function can be exploited to cause a heap-based buffer overflow by tricking a user or application using libvncserver to connect to an unstrusted server and subsequently send cursor shapes with specially crafted dimensions. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2019-15690 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15690.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2019-15690"
},
{
"cve": "CVE-2019-20788",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "libvncclient/cursor.c in LibVNCServer through 0.9.12 has a HandleCursorShape integer overflow and heap-based buffer overflow via a large height or width value. NOTE: this may overlap CVE-2019-15690.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2019-20788 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20788.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2019-20788"
},
{
"cve": "CVE-2019-20839",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "libvncclient/sockets.c in LibVNCServer before 0.9.13 has a buffer overflow via a long socket filename.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2019-20839 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20839.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2019-20839"
},
{
"cve": "CVE-2019-20840",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/ws_decode.c can lead to a crash because of unaligned accesses in hybiReadAndDecode.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2019-20840 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20840.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2019-20840"
},
{
"cve": "CVE-2020-14396",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14396 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14396.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14396"
},
{
"cve": "CVE-2020-14397",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/rfbregion.c has a NULL pointer dereference.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14397 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14397.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14397"
},
{
"cve": "CVE-2020-14398",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. An improperly closed TCP connection causes an infinite loop in libvncclient/sockets.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14398 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14398.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14398"
},
{
"cve": "CVE-2020-14401",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/scale.c has a pixel_value integer overflow.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14401 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14401.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14401"
},
{
"cve": "CVE-2020-14402",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/corre.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14402 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14402.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14402"
},
{
"cve": "CVE-2020-14403",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/hextile.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14403 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14403.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14403"
},
{
"cve": "CVE-2020-14404",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/rre.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14404 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14404.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14404"
},
{
"cve": "CVE-2020-14405",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/rfbproto.c does not limit TextChat size.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"summary": "CVE-2020-14405 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14405.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2020-14405"
}
]
}
FKIE_CVE-2020-14396
Vulnerability from fkie_nvd - Published: 2020-06-17 16:15 - Updated: 2024-11-21 05:03| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf | Patch, Third Party Advisory | |
| cve@mitre.org | https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553 | Patch, Third Party Advisory | |
| cve@mitre.org | https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13 | Release Notes, Third Party Advisory | |
| cve@mitre.org | https://usn.ubuntu.com/4434-1/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf | Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553 | Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13 | Release Notes, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://usn.ubuntu.com/4434-1/ | Third Party Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| libvnc_project | libvncserver | * | |
| canonical | ubuntu_linux | 14.04 | |
| canonical | ubuntu_linux | 16.04 | |
| canonical | ubuntu_linux | 16.04 | |
| canonical | ubuntu_linux | 18.04 | |
| canonical | ubuntu_linux | 18.10 | |
| canonical | ubuntu_linux | 20.04 | |
| debian | debian_linux | 8.0 | |
| debian | debian_linux | 9.0 | |
| siemens | simatic_itc1500_firmware | * | |
| siemens | simatic_itc1500 | - | |
| siemens | simatic_itc1500_pro_firmware | * | |
| siemens | simatic_itc1500_pro | - | |
| siemens | simatic_itc1900_firmware | * | |
| siemens | simatic_itc1900 | - | |
| siemens | simatic_itc1900_pro_firmware | * | |
| siemens | simatic_itc1900_pro | - | |
| siemens | simatic_itc2200_firmware | * | |
| siemens | simatic_itc2200 | - | |
| siemens | simatic_itc2200_pro_firmware | * | |
| siemens | simatic_itc2200_pro | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:libvnc_project:libvncserver:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A03A7282-D445-4E26-98A0-6A1597838D35",
"versionEndIncluding": "0.9.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:lts:*:*:*",
"matchCriteriaId": "B5A6F2F3-4894-4392-8296-3B8DD2679084",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*",
"matchCriteriaId": "7A5301BF-1402-4BE0-A0F8-69FBE79BC6D6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*",
"matchCriteriaId": "F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*",
"matchCriteriaId": "23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:18.10:*:*:*:*:*:*:*",
"matchCriteriaId": "07C312A0-CD2C-4B9C-B064-6409B25C278F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*",
"matchCriteriaId": "902B8056-9E37-443B-8905-8AA93E2447FB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C11E6FB0-C8C0-4527-9AA0-CB9B316F8F43",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc1500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A664216-EEA0-423F-8E11-59C746FDEEFE",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc1500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9596C8CD-B03F-4E9D-82AB-0986FDD1B47C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc1500_pro_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD78291E-48D8-4718-AE14-BDF93BD557D7",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc1500_pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BB898D3-07A3-42A1-8F1B-53C3B005982D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc1900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AD1209DE-2724-493D-8276-1BE959BFE6BF",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc1900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A9143A6-A93A-45CA-8A1F-6EE30647B54A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc1900_pro_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "92F7FC17-F19F-4BD6-9704-49B67D22B532",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc1900_pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3D34BD13-4E71-48A2-851D-AE7CE2A03C28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE4A6F13-385B-4A13-B8D8-3BBC4E9D5B67",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc2200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3E63E423-7450-4043-B33B-3FFF5BBE1CB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_itc2200_pro_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "71A51CA4-1A62-47BC-99A3-4DC9F3986FF5",
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_itc2200_pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD278558-AB0E-4FC1-9E5B-6B57D29CB86A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en LibVNCServer versiones anteriores a 0.9.13. La biblioteca libvncclient/tls_openssl.c presenta una desreferencia del puntero NULL"
}
],
"id": "CVE-2020-14396",
"lastModified": "2024-11-21T05:03:10.293",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-17T16:15:11.697",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"source": "cve@mitre.org",
"tags": [
"Release Notes",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://usn.ubuntu.com/4434-1/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
SSA-390195
Vulnerability from csaf_siemens - Published: 2021-12-14 00:00 - Updated: 2021-12-14 00:00Notes
{
"document": {
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Multiple LibVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-390195.txt"
},
{
"category": "self",
"summary": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-390195.json"
}
],
"title": "SSA-390195: LibVNC Vulnerabilities in SIMATIC ITC Products",
"tracking": {
"current_release_date": "2021-12-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-390195",
"initial_release_date": "2021-12-14T00:00:00Z",
"revision_history": [
{
"date": "2021-12-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC1500 V3",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1500 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC1500 V3 PRO",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1500 V3 PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC1900 V3",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1900 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC1900 V3 PRO",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC1900 V3 PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC2200 V3",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC2200 V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.2.1.0",
"product": {
"name": "SIMATIC ITC2200 V3 PRO",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC ITC2200 V3 PRO"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-18922",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2017-18922 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2017-18922 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2017-18922.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2017-18922"
},
{
"cve": "CVE-2018-20019",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2018-20019 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20019 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20019.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2018-20019"
},
{
"cve": "CVE-2018-20748",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c. The fix for CVE-2018-20019 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2018-20748 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20748 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20748.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2018-20748"
},
{
"cve": "CVE-2018-20749",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2018-20749 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20749 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20749.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2018-20749"
},
{
"cve": "CVE-2018-20750",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "LibVNC through 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2018-20750 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-20750 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-20750.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2018-20750"
},
{
"cve": "CVE-2018-21247",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. There is an information leak (of uninitialized memory contents) in the libvncclient/rfbproto.c ConnectToRFBRepeater function.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2018-21247 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2018-21247 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-21247.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2018-21247"
},
{
"cve": "CVE-2019-15681",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2019-15681 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15681 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15681.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2019-15681"
},
{
"cve": "CVE-2019-15690",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A flaw was found in libvncserver. An integer overflow within the HandleCursorShape() function can be exploited to cause a heap-based buffer overflow by tricking a user or application using libvncserver to connect to an unstrusted server and subsequently send cursor shapes with specially crafted dimensions. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2019-15690 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-15690 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15690.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2019-15690"
},
{
"cve": "CVE-2019-20788",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "libvncclient/cursor.c in LibVNCServer through 0.9.12 has a HandleCursorShape integer overflow and heap-based buffer overflow via a large height or width value. NOTE: this may overlap CVE-2019-15690.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2019-20788 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20788 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20788.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2019-20788"
},
{
"cve": "CVE-2019-20839",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "libvncclient/sockets.c in LibVNCServer before 0.9.13 has a buffer overflow via a long socket filename.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2019-20839 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20839 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20839.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2019-20839"
},
{
"cve": "CVE-2019-20840",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/ws_decode.c can lead to a crash because of unaligned accesses in hybiReadAndDecode.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2019-20840 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2019-20840 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-20840.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2019-20840"
},
{
"cve": "CVE-2020-14396",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14396 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14396 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14396.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14396"
},
{
"cve": "CVE-2020-14397",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/rfbregion.c has a NULL pointer dereference.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14397 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14397 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14397.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14397"
},
{
"cve": "CVE-2020-14398",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. An improperly closed TCP connection causes an infinite loop in libvncclient/sockets.c.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14398 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14398 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14398.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14398"
},
{
"cve": "CVE-2020-14401",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/scale.c has a pixel_value integer overflow.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14401 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14401 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14401.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14401"
},
{
"cve": "CVE-2020-14402",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/corre.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14402 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14402 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14402.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14402"
},
{
"cve": "CVE-2020-14403",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/hextile.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14403 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14403 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14403.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14403"
},
{
"cve": "CVE-2020-14404",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncserver/rre.c allows out-of-bounds access via encodings.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14404 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14404 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14404.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14404"
},
{
"cve": "CVE-2020-14405",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/rfbproto.c does not limit TextChat size.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"references": [
{
"summary": "CVE-2020-14405 - SIMATIC ITC1500 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1500 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1900 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC1900 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC2200 V3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 - SIMATIC ITC2200 V3 PRO",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"summary": "CVE-2020-14405 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-14405.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2.1.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109804128/"
},
{
"category": "mitigation",
"details": "Monitor and restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-14405"
}
]
}
GSD-2020-14396
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-14396",
"description": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.",
"id": "GSD-2020-14396",
"references": [
"https://www.suse.com/security/cve/CVE-2020-14396.html",
"https://ubuntu.com/security/CVE-2020-14396"
]
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-14396"
],
"details": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.",
"id": "GSD-2020-14396",
"modified": "2023-12-13T01:21:59.833781Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-14396",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13",
"refsource": "MISC",
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"name": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553",
"refsource": "MISC",
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"name": "USN-4434-1",
"refsource": "UBUNTU",
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:libvnc_project:libvncserver:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "0.9.12",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:lts:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:18.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc1500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc1500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc1500_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc1500_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc1900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc1900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc1900_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc1900_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc2200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc2200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_itc2200_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.2.1.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_itc2200_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-14396"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13",
"refsource": "MISC",
"tags": [
"Release Notes",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"name": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553",
"refsource": "MISC",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"name": "USN-4434-1",
"refsource": "UBUNTU",
"tags": [
"Third Party Advisory"
],
"url": "https://usn.ubuntu.com/4434-1/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-03-10T15:15Z",
"publishedDate": "2020-06-17T16:15Z"
}
}
}
CNVD-2020-36782
Vulnerability from cnvd - Published: 2020-07-07目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553
| Name | LibVNCServer LibVNCServer <0.9.13 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-14396"
}
},
"description": "LibVNCServer\u662f\u4e00\u6b3e\u652f\u6301\u5728\u7a0b\u5e8f\u4e2d\u5b9e\u73b0VNC\uff08\u865a\u62df\u7f51\u7edc\u8ba1\u7b97\uff09\u670d\u52a1\u5668\u6216\u5ba2\u6237\u7aef\u529f\u80fd\u7684\u8de8\u5e73\u53f0C\u8bed\u8a00\u5e93\u3002\n\nLibVNCServer 0.9.13\u4e4b\u524d\u7248\u672c\u4e2d\u7684libvncclient/tls_openssl.c\u6587\u4ef6\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u5e94\u7528\u7a0b\u5e8f\u5d29\u6e83\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-36782",
"openTime": "2020-07-07",
"patchDescription": "LibVNCServer\u662f\u4e00\u6b3e\u652f\u6301\u5728\u7a0b\u5e8f\u4e2d\u5b9e\u73b0VNC\uff08\u865a\u62df\u7f51\u7edc\u8ba1\u7b97\uff09\u670d\u52a1\u5668\u6216\u5ba2\u6237\u7aef\u529f\u80fd\u7684\u8de8\u5e73\u53f0C\u8bed\u8a00\u5e93\u3002\r\n\r\nLibVNCServer 0.9.13\u4e4b\u524d\u7248\u672c\u4e2d\u7684libvncclient/tls_openssl.c\u6587\u4ef6\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u5e94\u7528\u7a0b\u5e8f\u5d29\u6e83\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "LibVNCServer\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff08CNVD-2020-36782\uff09\u7684\u8865\u4e01",
"products": {
"product": "LibVNCServer LibVNCServer \u003c0.9.13"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2020-14396",
"serverity": "\u4e2d",
"submitTime": "2020-06-18",
"title": "LibVNCServer\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff08CNVD-2020-36782\uff09"
}
GHSA-F7MR-G388-R763
Vulnerability from github – Published: 2022-05-24 17:20 – Updated: 2022-05-24 17:20An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.
{
"affected": [],
"aliases": [
"CVE-2020-14396"
],
"database_specific": {
"cwe_ids": [
"CWE-476"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-06-17T16:15:00Z",
"severity": "MODERATE"
},
"details": "An issue was discovered in LibVNCServer before 0.9.13. libvncclient/tls_openssl.c has a NULL pointer dereference.",
"id": "GHSA-f7mr-g388-r763",
"modified": "2022-05-24T17:20:47Z",
"published": "2022-05-24T17:20:47Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-14396"
},
{
"type": "WEB",
"url": "https://github.com/LibVNC/libvncserver/commit/33441d90a506d5f3ae9388f2752901227e430553"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"type": "WEB",
"url": "https://github.com/LibVNC/libvncserver/compare/LibVNCServer-0.9.12...LibVNCServer-0.9.13"
},
{
"type": "WEB",
"url": "https://usn.ubuntu.com/4434-1"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
CERTFR-2021-AVI-949
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions antérieures à 21.00 SP3 | ||
| Siemens | N/A | Siveillance Identity V5 versions antérieures à 1.6.284, ou sans le correctif de sécurité SP5 | ||
| Siemens | N/A | SIMATIC ITC2200 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | Desigo PXC22.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SINUMERIK Edge versions antérieures à 3.2 | ||
| Siemens | N/A | Desigo PXC36.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Capital VSTAR toutes versions avec l'option Ethernet activée | ||
| Siemens | N/A | JTTK versions antérieures à 11.1.1.0 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.2.x antérieures à 5.2.3 | ||
| Siemens | N/A | Desigo PXC00-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Questa Simulation toutes versions | ||
| Siemens | N/A | Desigo PXC00-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SIMATIC ITC1900 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC1900 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC1500 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC2200 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.1.1.0 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC001-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC64-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.0.x antérieures à 5.0.10 | ||
| Siemens | N/A | ModelSim Simulation toutes versions | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.1.x antérieures à 5.1.6 | ||
| Siemens | N/A | Desigo PXC200-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC12-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 4.3.x antérieures à V4.3.11 | ||
| Siemens | N/A | SIMATIC ITC1500 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | JT Utilities versions antérieures à 12.8.1.1 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.85 | ||
| Siemens | N/A | Teamcenter Visualization versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | Desigo PXC22-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.0.3.0 | ||
| Siemens | N/A | Simcenter STAR-CCM+ Viewer versions antérieures à 2021.3.1 | ||
| Siemens | N/A | Siveillance Identity V1.6 versions antérieures à 1.6.284.0 | ||
| Siemens | N/A | JTTK versions antérieures à 10.8.1.1 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC100-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.76 | ||
| Siemens | N/A | Desigo PXC50-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | JT2Go versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | JTTK versions antérieures à 11.0.3.0 | ||
| Siemens | N/A | Desigo PXC128-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.80 | ||
| Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à 2.41 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "APOGEE MEC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions ant\u00e9rieures \u00e0 21.00 SP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V5 versions ant\u00e9rieures \u00e0 1.6.284, ou sans le correctif de s\u00e9curit\u00e9 SP5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Edge versions ant\u00e9rieures \u00e0 3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC36.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Capital VSTAR toutes versions avec l\u0027option Ethernet activ\u00e9e",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.2.x ant\u00e9rieures \u00e0 5.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Questa Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC001-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC64-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.0.x ant\u00e9rieures \u00e0 5.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ModelSim Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.1.x ant\u00e9rieures \u00e0 5.1.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC200-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC12-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 4.3.x ant\u00e9rieures \u00e0 V4.3.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 12.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.85",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 2021.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V1.6 versions ant\u00e9rieures \u00e0 1.6.284.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 10.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC100-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.76",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC50-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC128-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-44443",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44443"
},
{
"name": "CVE-2021-31881",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31881"
},
{
"name": "CVE-2021-44444",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44444"
},
{
"name": "CVE-2021-44009",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44009"
},
{
"name": "CVE-2021-31888",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31888"
},
{
"name": "CVE-2021-44447",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44447"
},
{
"name": "CVE-2018-20749",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20749"
},
{
"name": "CVE-2021-44013",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44013"
},
{
"name": "CVE-2021-31885",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31885"
},
{
"name": "CVE-2021-31887",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31887"
},
{
"name": "CVE-2019-15690",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15690"
},
{
"name": "CVE-2021-44012",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44012"
},
{
"name": "CVE-2020-14396",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14396"
},
{
"name": "CVE-2021-44001",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44001"
},
{
"name": "CVE-2020-14404",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14404"
},
{
"name": "CVE-2021-44430",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44430"
},
{
"name": "CVE-2021-44440",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44440"
},
{
"name": "CVE-2021-44432",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44432"
},
{
"name": "CVE-2021-44445",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44445"
},
{
"name": "CVE-2021-31884",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31884"
},
{
"name": "CVE-2021-44434",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44434"
},
{
"name": "CVE-2021-44449",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44449"
},
{
"name": "CVE-2019-15681",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15681"
},
{
"name": "CVE-2021-44435",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44435"
},
{
"name": "CVE-2021-42023",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42023"
},
{
"name": "CVE-2021-44442",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44442"
},
{
"name": "CVE-2021-44002",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44002"
},
{
"name": "CVE-2021-44014",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44014"
},
{
"name": "CVE-2021-44436",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44436"
},
{
"name": "CVE-2021-31882",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31882"
},
{
"name": "CVE-2021-44438",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44438"
},
{
"name": "CVE-2021-44006",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44006"
},
{
"name": "CVE-2021-41547",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41547"
},
{
"name": "CVE-2021-44008",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44008"
},
{
"name": "CVE-2021-44017",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44017"
},
{
"name": "CVE-2021-44441",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44441"
},
{
"name": "CVE-2021-44011",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44011"
},
{
"name": "CVE-2018-20748",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20748"
},
{
"name": "CVE-2019-20788",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20788"
},
{
"name": "CVE-2021-44446",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44446"
},
{
"name": "CVE-2021-44010",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44010"
},
{
"name": "CVE-2021-44522",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44522"
},
{
"name": "CVE-2021-44448",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44448"
},
{
"name": "CVE-2021-44523",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44523"
},
{
"name": "CVE-2019-20840",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20840"
},
{
"name": "CVE-2021-31346",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31346"
},
{
"name": "CVE-2018-20750",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20750"
},
{
"name": "CVE-2021-42022",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42022"
},
{
"name": "CVE-2021-44433",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44433"
},
{
"name": "CVE-2021-44004",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44004"
},
{
"name": "CVE-2017-18922",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-18922"
},
{
"name": "CVE-2021-44524",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44524"
},
{
"name": "CVE-2021-44003",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44003"
},
{
"name": "CVE-2021-44007",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44007"
},
{
"name": "CVE-2021-42024",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42024"
},
{
"name": "CVE-2019-20839",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20839"
},
{
"name": "CVE-2021-44431",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44431"
},
{
"name": "CVE-2021-31889",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31889"
},
{
"name": "CVE-2021-44005",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44005"
},
{
"name": "CVE-2020-14402",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14402"
},
{
"name": "CVE-2020-14397",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14397"
},
{
"name": "CVE-2021-31883",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31883"
},
{
"name": "CVE-2020-14398",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14398"
},
{
"name": "CVE-2020-14403",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14403"
},
{
"name": "CVE-2021-44439",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44439"
},
{
"name": "CVE-2021-44015",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44015"
},
{
"name": "CVE-2021-44437",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44437"
},
{
"name": "CVE-2021-31886",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31886"
},
{
"name": "CVE-2021-44450",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44450"
},
{
"name": "CVE-2021-42027",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42027"
},
{
"name": "CVE-2021-31890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31890"
},
{
"name": "CVE-2020-14405",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14405"
},
{
"name": "CVE-2021-31345",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31345"
},
{
"name": "CVE-2018-20019",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20019"
},
{
"name": "CVE-2018-15127",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15127"
},
{
"name": "CVE-2018-21247",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-21247"
},
{
"name": "CVE-2021-44165",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44165"
},
{
"name": "CVE-2021-31344",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31344"
},
{
"name": "CVE-2020-14401",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14401"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-949",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-12-15T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-620288 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-133772 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-133772.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-199605 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-595101 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-496292 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-400332 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-400332.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-463116 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-523250 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523250.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-352143 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-390195 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-396621 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-802578 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-160202 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-161331 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-161331.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
}
]
}
CERTFR-2021-AVI-949
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions antérieures à 21.00 SP3 | ||
| Siemens | N/A | Siveillance Identity V5 versions antérieures à 1.6.284, ou sans le correctif de sécurité SP5 | ||
| Siemens | N/A | SIMATIC ITC2200 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | Desigo PXC22.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SINUMERIK Edge versions antérieures à 3.2 | ||
| Siemens | N/A | Desigo PXC36.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Capital VSTAR toutes versions avec l'option Ethernet activée | ||
| Siemens | N/A | JTTK versions antérieures à 11.1.1.0 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.2.x antérieures à 5.2.3 | ||
| Siemens | N/A | Desigo PXC00-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Questa Simulation toutes versions | ||
| Siemens | N/A | Desigo PXC00-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SIMATIC ITC1900 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC1900 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC1500 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC2200 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.1.1.0 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC001-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC64-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.0.x antérieures à 5.0.10 | ||
| Siemens | N/A | ModelSim Simulation toutes versions | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.1.x antérieures à 5.1.6 | ||
| Siemens | N/A | Desigo PXC200-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC12-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 4.3.x antérieures à V4.3.11 | ||
| Siemens | N/A | SIMATIC ITC1500 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | JT Utilities versions antérieures à 12.8.1.1 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.85 | ||
| Siemens | N/A | Teamcenter Visualization versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | Desigo PXC22-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.0.3.0 | ||
| Siemens | N/A | Simcenter STAR-CCM+ Viewer versions antérieures à 2021.3.1 | ||
| Siemens | N/A | Siveillance Identity V1.6 versions antérieures à 1.6.284.0 | ||
| Siemens | N/A | JTTK versions antérieures à 10.8.1.1 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC100-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.76 | ||
| Siemens | N/A | Desigo PXC50-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | JT2Go versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | JTTK versions antérieures à 11.0.3.0 | ||
| Siemens | N/A | Desigo PXC128-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.80 | ||
| Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à 2.41 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "APOGEE MEC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions ant\u00e9rieures \u00e0 21.00 SP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V5 versions ant\u00e9rieures \u00e0 1.6.284, ou sans le correctif de s\u00e9curit\u00e9 SP5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Edge versions ant\u00e9rieures \u00e0 3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC36.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Capital VSTAR toutes versions avec l\u0027option Ethernet activ\u00e9e",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.2.x ant\u00e9rieures \u00e0 5.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Questa Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC001-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC64-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.0.x ant\u00e9rieures \u00e0 5.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ModelSim Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.1.x ant\u00e9rieures \u00e0 5.1.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC200-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC12-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 4.3.x ant\u00e9rieures \u00e0 V4.3.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 12.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.85",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 2021.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V1.6 versions ant\u00e9rieures \u00e0 1.6.284.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 10.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC100-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.76",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC50-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC128-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-44443",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44443"
},
{
"name": "CVE-2021-31881",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31881"
},
{
"name": "CVE-2021-44444",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44444"
},
{
"name": "CVE-2021-44009",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44009"
},
{
"name": "CVE-2021-31888",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31888"
},
{
"name": "CVE-2021-44447",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44447"
},
{
"name": "CVE-2018-20749",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20749"
},
{
"name": "CVE-2021-44013",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44013"
},
{
"name": "CVE-2021-31885",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31885"
},
{
"name": "CVE-2021-31887",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31887"
},
{
"name": "CVE-2019-15690",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15690"
},
{
"name": "CVE-2021-44012",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44012"
},
{
"name": "CVE-2020-14396",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14396"
},
{
"name": "CVE-2021-44001",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44001"
},
{
"name": "CVE-2020-14404",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14404"
},
{
"name": "CVE-2021-44430",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44430"
},
{
"name": "CVE-2021-44440",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44440"
},
{
"name": "CVE-2021-44432",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44432"
},
{
"name": "CVE-2021-44445",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44445"
},
{
"name": "CVE-2021-31884",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31884"
},
{
"name": "CVE-2021-44434",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44434"
},
{
"name": "CVE-2021-44449",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44449"
},
{
"name": "CVE-2019-15681",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15681"
},
{
"name": "CVE-2021-44435",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44435"
},
{
"name": "CVE-2021-42023",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42023"
},
{
"name": "CVE-2021-44442",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44442"
},
{
"name": "CVE-2021-44002",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44002"
},
{
"name": "CVE-2021-44014",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44014"
},
{
"name": "CVE-2021-44436",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44436"
},
{
"name": "CVE-2021-31882",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31882"
},
{
"name": "CVE-2021-44438",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44438"
},
{
"name": "CVE-2021-44006",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44006"
},
{
"name": "CVE-2021-41547",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41547"
},
{
"name": "CVE-2021-44008",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44008"
},
{
"name": "CVE-2021-44017",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44017"
},
{
"name": "CVE-2021-44441",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44441"
},
{
"name": "CVE-2021-44011",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44011"
},
{
"name": "CVE-2018-20748",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20748"
},
{
"name": "CVE-2019-20788",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20788"
},
{
"name": "CVE-2021-44446",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44446"
},
{
"name": "CVE-2021-44010",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44010"
},
{
"name": "CVE-2021-44522",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44522"
},
{
"name": "CVE-2021-44448",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44448"
},
{
"name": "CVE-2021-44523",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44523"
},
{
"name": "CVE-2019-20840",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20840"
},
{
"name": "CVE-2021-31346",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31346"
},
{
"name": "CVE-2018-20750",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20750"
},
{
"name": "CVE-2021-42022",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42022"
},
{
"name": "CVE-2021-44433",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44433"
},
{
"name": "CVE-2021-44004",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44004"
},
{
"name": "CVE-2017-18922",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-18922"
},
{
"name": "CVE-2021-44524",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44524"
},
{
"name": "CVE-2021-44003",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44003"
},
{
"name": "CVE-2021-44007",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44007"
},
{
"name": "CVE-2021-42024",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42024"
},
{
"name": "CVE-2019-20839",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20839"
},
{
"name": "CVE-2021-44431",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44431"
},
{
"name": "CVE-2021-31889",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31889"
},
{
"name": "CVE-2021-44005",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44005"
},
{
"name": "CVE-2020-14402",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14402"
},
{
"name": "CVE-2020-14397",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14397"
},
{
"name": "CVE-2021-31883",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31883"
},
{
"name": "CVE-2020-14398",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14398"
},
{
"name": "CVE-2020-14403",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14403"
},
{
"name": "CVE-2021-44439",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44439"
},
{
"name": "CVE-2021-44015",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44015"
},
{
"name": "CVE-2021-44437",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44437"
},
{
"name": "CVE-2021-31886",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31886"
},
{
"name": "CVE-2021-44450",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44450"
},
{
"name": "CVE-2021-42027",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42027"
},
{
"name": "CVE-2021-31890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31890"
},
{
"name": "CVE-2020-14405",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14405"
},
{
"name": "CVE-2021-31345",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31345"
},
{
"name": "CVE-2018-20019",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20019"
},
{
"name": "CVE-2018-15127",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15127"
},
{
"name": "CVE-2018-21247",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-21247"
},
{
"name": "CVE-2021-44165",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44165"
},
{
"name": "CVE-2021-31344",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31344"
},
{
"name": "CVE-2020-14401",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14401"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-949",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-12-15T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-620288 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-133772 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-133772.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-199605 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-595101 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-496292 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-400332 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-400332.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-463116 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-523250 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523250.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-352143 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-390195 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-396621 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-802578 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-160202 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-161331 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-161331.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.