cve-2020-14431
Vulnerability from cvelistv5
Published
2020-06-18 16:26
Modified
2024-08-04 12:46
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:26:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14431", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14431", "datePublished": "2020-06-18T16:26:41", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.563Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"EE271234-71E6-4F3A-8F39-DA86D1275331\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A45832BD-114D-42F1-B9F1-7532496D30A6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"436BED04-0FD2-499B-9D42-F9E0AAA6CB97\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"56AE9F2F-50F1-4917-BB21-FAEE6AACB14E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"F35DDDEC-A64B-400E-ABF8-E13F432BD261\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"192647CA-5BFC-4021-A91D-7CB8761FA137\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"905C4D26-8575-429C-B1D2-FC35C773B129\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C13F5C69-FA9B-472A-9036-0C2967BDCDE9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"F60A549C-0D76-4A83-BBCD-C1D04075809B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B529194C-C440-4BC3-850F-0613FC548F86\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0E9B19B2-5FF1-4C85-8504-C33C34F072B1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"D19A1E4D-30F2-4263-B4BE-273EED14702E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4489CB05-A1C0-408C-8D8C-56EE98CA20E8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"44ED0285-F862-44B9-B0EE-C2FDC42706A2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"84AEA27B-8BEA-4E83-819A-FDAC1881928F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"7300226F-8997-4142-8DAC-682F0E313072\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"14F257FE-31CE-4F74-829D-29407D74ADF7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"A553C5A2-EB80-4314-A623-8F489A4E74E2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4479CEAD-3B87-4993-80C8-1AE59242CFA4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"86A9DFB9-8429-45DB-84E8-30F37535145E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D92E4C8E-222A-476C-8273-F7171FC61F0B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.15.25\", \"matchCriteriaId\": \"B4FC4E2F-711C-432A-91FE-27CB1EE41A33\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"221CA950-E984-44CD-9E1B-3AADE3CEBE52\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por una divulgaci\\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25\"}]", "id": "CVE-2020-14431", "lastModified": "2024-11-21T05:03:15.320", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L\", \"baseScore\": 9.6, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 3.3, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.5, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2020-06-18T17:15:12.250", "references": "[{\"url\": \"https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-14431\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-06-18T17:15:12.250\",\"lastModified\":\"2024-11-21T05:03:15.320\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":3.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.5,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"EE271234-71E6-4F3A-8F39-DA86D1275331\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A45832BD-114D-42F1-B9F1-7532496D30A6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"436BED04-0FD2-499B-9D42-F9E0AAA6CB97\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56AE9F2F-50F1-4917-BB21-FAEE6AACB14E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"F35DDDEC-A64B-400E-ABF8-E13F432BD261\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"192647CA-5BFC-4021-A91D-7CB8761FA137\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"905C4D26-8575-429C-B1D2-FC35C773B129\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C13F5C69-FA9B-472A-9036-0C2967BDCDE9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"F60A549C-0D76-4A83-BBCD-C1D04075809B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B529194C-C440-4BC3-850F-0613FC548F86\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E9B19B2-5FF1-4C85-8504-C33C34F072B1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"D19A1E4D-30F2-4263-B4BE-273EED14702E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4489CB05-A1C0-408C-8D8C-56EE98CA20E8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"44ED0285-F862-44B9-B0EE-C2FDC42706A2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84AEA27B-8BEA-4E83-819A-FDAC1881928F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"7300226F-8997-4142-8DAC-682F0E313072\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"14F257FE-31CE-4F74-829D-29407D74ADF7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"A553C5A2-EB80-4314-A623-8F489A4E74E2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4479CEAD-3B87-4993-80C8-1AE59242CFA4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"86A9DFB9-8429-45DB-84E8-30F37535145E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D92E4C8E-222A-476C-8273-F7171FC61F0B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.15.25\",\"matchCriteriaId\":\"B4FC4E2F-711C-432A-91FE-27CB1EE41A33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"221CA950-E984-44CD-9E1B-3AADE3CEBE52\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.