cve-2020-16229
Vulnerability from cvelistv5
Published
2020-08-06 18:24
Modified
2024-08-04 13:37
Severity ?
Summary
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:37:54.174Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-954/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Advantech WebAccess HMI Designer",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 2.1.9.31 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-10T16:06:12",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-954/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-16229",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Advantech WebAccess HMI Designer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 2.1.9.31 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-954/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-954/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-16229",
    "datePublished": "2020-08-06T18:24:10",
    "dateReserved": "2020-07-31T00:00:00",
    "dateUpdated": "2024-08-04T13:37:54.174Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-16229\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-08-06T19:15:13.987\",\"lastModified\":\"2022-10-06T23:52:12.270\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.\"},{\"lang\":\"es\",\"value\":\"Advantech WebAccess HMI Designer, versiones 2.1.9.31 y anteriores. El procesamiento de archivos de proyecto especialmente dise\u00f1ados carecen de comprobaci\u00f3n apropiada de los datos proporcionados por un usuario puede causar una condici\u00f3n de confusi\u00f3n de tipo, lo que puede permitir una ejecuci\u00f3n de c\u00f3digo remota, divulgaci\u00f3n y modificaci\u00f3n de informaci\u00f3n o causar que la aplicaci\u00f3n se bloquee\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:webaccess\\\\/hmi_designer:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.1.9.31\",\"matchCriteriaId\":\"B10BE31F-862E-4C94-A25A-D8F86CE09C9F\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-20-954/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.